Determination of Light Source Modules on Blood Glucose Biomimetics Using he Reflectance Method

被引:2
|
作者
Prastowo, Bayu [1 ]
Jenie, Renan Prasta [1 ,2 ]
Hardyanto, Ichsan [1 ]
Dahrul, Muhammad [1 ]
Iskandar, Johan [3 ]
Kurniawan, Ade [4 ]
Siskandar, Ridwan [5 ]
Nurdin, Naufal Muharram [6 ]
Suryana, Yaya [7 ]
Pambudi, Sabar [8 ]
Widayanti, Tika [8 ]
Aridarma, Arga [9 ]
Rahayu, Maria Sri Kristina [9 ]
Riadhie, Titah Sihdjati [9 ]
Irzaman [1 ]
Alatas, Husin [1 ]
机构
[1] IPB Univ, Dept Phys, Bogor, Jawa Barat, Indonesia
[2] Binawan Univ, Dept Publ Hlth, Jakarta, Indonesia
[3] Pakuan Univ, Vocat Sch, Bogor, Jawa Barat, Indonesia
[4] Sunan Kalijaga State Islamic Univ, Dept Phys, Yogyakarta 55281, Indonesia
[5] IPB Univ, Vocat Sch, Bogor, Jawa Barat, Indonesia
[6] IPB Univ, Dept Community Nutr, Bogor, Jawa Barat, Indonesia
[7] Agcy Assessment & Applicat Technol BPPT, Ctr Elect Technol, Jakarta 10340, Indonesia
[8] Agcy Assessment & Applicat Technol BPPT, Ctr Pharm & Med Technol, Jakarta 10340, Indonesia
[9] PT Tesena Inovindo, Jakarta, Indonesia
来源
关键词
HISTORY;
D O I
10.1063/5.0037485
中图分类号
G40 [教育学];
学科分类号
040101 ; 120403 ;
摘要
Developing blood glucoselevels measurement based on the prevalence of people with impaired glucose metabolism, which is increasing every year. Estimates of the International Diabetes Federation and the American Diabetes Association in 2030 sufferers of glucose metabolism disorders have twofold from 2018. Prevention can be done with monitoring measurement methods that have been available commercially. This research develops a non-invasive biomarker device method that aims at continuous measurement efficiency with minimal risk and reduces production costs. The measurement used standard samples Lyphocheck Assayed Chemistry Control from Bio-Rad Laboratory. The light source modules were tested in the wavelength range of 1050 nm to 1550 nm and FDG03-Ge Photodiode as a photodetector. Then the reflections of the LEDs is a voltage that is converted to analog with Analogue to Digital Converter devices to be processed at the SQ Lite and LibreOffice Calc. Based on the test analysis parameters obtained the two best candidate light source modules are 1050 nm and 1085 nm with a 0.99 pearson correlation, 86% accuracy and zone factor A or 100% value of error grid analysis. Both of these LEDs can be applied as modules in the measurement of blood glucose biomimetic with reflectance method.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] EXPERIENCE WITH GLUCOSE-DEHYDROGENASE-UV-METHOD FOR DETERMINATION OF BLOOD-GLUCOSE
    DOLHOFER, R
    WEISS, L
    WIELAND, OH
    JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1976, 14 (08): : 415 - 417
  • [42] Reflectance measurement using digital camera and a protecting dome with built in light source
    Valisuo, Petri
    Harju, Toni
    Alander, Jarmo
    JOURNAL OF BIOPHOTONICS, 2011, 4 (7-8) : 559 - 564
  • [43] EVALUATION OF A REFLECTANCE PHOTOMETRIC-METHOD FOR DETERMINATION OF UREA IN BLOOD, PLASMA, OR SERUM
    HAMMOND, BR
    LESTER, E
    CLINICAL CHEMISTRY, 1984, 30 (04) : 596 - 597
  • [44] Achievement of the noninvasive measurement for human blood glucose with NIR diffusion reflectance spectrum method
    Zhang, HY
    Ding, D
    Song, LQ
    Gu, LN
    Yang, P
    Tang, YG
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25 (06) : 882 - 885
  • [45] BLOOD-GLUCOSE DETERMINATION IN INFANTS AND CHILDREN - REFLECTANCE METER ENZYME TEST STRIP SYSTEM
    HAWORTH, JC
    VANWOERT, M
    DILLING, LA
    AMERICAN JOURNAL OF DISEASES OF CHILDREN, 1972, 123 (05): : 469 - &
  • [46] Development of a rapid method for determination of lactose in process cheese using blood glucose meter.
    Biswas, A. C.
    Amamcharla, J.
    Metzger, L. E.
    JOURNAL OF DAIRY SCIENCE, 2010, 93 : 75 - 75
  • [47] Application of a Spectroscopic Method for Noninvasive Determination of Glucose Content in Blood
    Gurevich, B. S.
    Dudnikov, S. Yu.
    Shapovalov, V. V.
    Zagorskii, I. G.
    RUSSIAN PHYSICS JOURNAL, 2019, 61 (12) : 2324 - 2326
  • [48] Direct spectrophotometric determination of the blood glucose by the method of conjugation enzyme
    Han, AX
    Wu, GS
    Liang, Q
    Zhang, FS
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2003, 31 (12) : 1417 - 1420
  • [49] A new sensitive spectrophotometric method for determination of saliva and blood glucose
    Mohammadnejad, Parvin
    Asl, Saeed Soleimani
    Aminzadeh, Saeed
    Haghbeen, Kamahldin
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2020, 229