Determination of Light Source Modules on Blood Glucose Biomimetics Using he Reflectance Method

被引:2
|
作者
Prastowo, Bayu [1 ]
Jenie, Renan Prasta [1 ,2 ]
Hardyanto, Ichsan [1 ]
Dahrul, Muhammad [1 ]
Iskandar, Johan [3 ]
Kurniawan, Ade [4 ]
Siskandar, Ridwan [5 ]
Nurdin, Naufal Muharram [6 ]
Suryana, Yaya [7 ]
Pambudi, Sabar [8 ]
Widayanti, Tika [8 ]
Aridarma, Arga [9 ]
Rahayu, Maria Sri Kristina [9 ]
Riadhie, Titah Sihdjati [9 ]
Irzaman [1 ]
Alatas, Husin [1 ]
机构
[1] IPB Univ, Dept Phys, Bogor, Jawa Barat, Indonesia
[2] Binawan Univ, Dept Publ Hlth, Jakarta, Indonesia
[3] Pakuan Univ, Vocat Sch, Bogor, Jawa Barat, Indonesia
[4] Sunan Kalijaga State Islamic Univ, Dept Phys, Yogyakarta 55281, Indonesia
[5] IPB Univ, Vocat Sch, Bogor, Jawa Barat, Indonesia
[6] IPB Univ, Dept Community Nutr, Bogor, Jawa Barat, Indonesia
[7] Agcy Assessment & Applicat Technol BPPT, Ctr Elect Technol, Jakarta 10340, Indonesia
[8] Agcy Assessment & Applicat Technol BPPT, Ctr Pharm & Med Technol, Jakarta 10340, Indonesia
[9] PT Tesena Inovindo, Jakarta, Indonesia
来源
关键词
HISTORY;
D O I
10.1063/5.0037485
中图分类号
G40 [教育学];
学科分类号
040101 ; 120403 ;
摘要
Developing blood glucoselevels measurement based on the prevalence of people with impaired glucose metabolism, which is increasing every year. Estimates of the International Diabetes Federation and the American Diabetes Association in 2030 sufferers of glucose metabolism disorders have twofold from 2018. Prevention can be done with monitoring measurement methods that have been available commercially. This research develops a non-invasive biomarker device method that aims at continuous measurement efficiency with minimal risk and reduces production costs. The measurement used standard samples Lyphocheck Assayed Chemistry Control from Bio-Rad Laboratory. The light source modules were tested in the wavelength range of 1050 nm to 1550 nm and FDG03-Ge Photodiode as a photodetector. Then the reflections of the LEDs is a voltage that is converted to analog with Analogue to Digital Converter devices to be processed at the SQ Lite and LibreOffice Calc. Based on the test analysis parameters obtained the two best candidate light source modules are 1050 nm and 1085 nm with a 0.99 pearson correlation, 86% accuracy and zone factor A or 100% value of error grid analysis. Both of these LEDs can be applied as modules in the measurement of blood glucose biomimetic with reflectance method.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Non-Invasive Measurement of Blood Glucose Biomimetics with the Reflectance Method on Near-Infrared Light Source
    Alatas, Husin
    Prastowo, Bayu
    Jenie, Renan Prasta
    Dahrul, Muhammad
    Hardyanto, Ichsan
    Iskandar, Johan
    Kurniawan, Ade
    Siskandar, Ridwan
    Nurdin, Naufal Muharram
    Suryana, Yaya
    Pambudi, Sabar
    Widayanti, Tika
    Aridarma, Arga
    Rahayu, Maria Sri Kristina
    Riadhie, Titah Sihdjati
    Irzaman
    9TH NATIONAL PHYSICS SEMINAR 2020, 2021, 2320
  • [2] Non-invasive Blood Glucose Determination using Near Infrared LED in Diffused Reflectance Method
    Arefin, Mohammed Shahriar
    Khan, Adnan Hossain
    Islam, Rabiul
    2018 10TH INTERNATIONAL CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (ICECE), 2018, : 93 - 96
  • [3] WHOLE-BLOOD GLUCOSE DETERMINATION IN DOGS USING DEXTROSTIX AND THE EYETONE REFLECTANCE COLORIMETER
    CHURCH, DB
    WATSON, ADJ
    JOURNAL OF SMALL ANIMAL PRACTICE, 1979, 20 (03) : 163 - 168
  • [5] ACCURACY AND RELIABILITY OF NEONATAL BLOOD-GLUCOSE DETERMINATION BY GLUCOSE REFLECTANCE METERS
    COWETT, RM
    DAMICO, LB
    PEDIATRIC RESEARCH, 1991, 29 (04) : A209 - A209
  • [6] BLOOD-GLUCOSE DETERMINATION THE USE OF A NEW REFLECTANCE PHOTOMETER
    STICKLAND, MH
    WALES, JK
    PRACTITIONER, 1982, 226 (1364) : 271 - 272
  • [7] Reflectance Pulse Oximetry Using Single Light Source
    Kumar, Jyothish M.
    Kumar, Arun, V
    INTERNATIONAL CONFERENCE ON MODELLING OPTIMIZATION AND COMPUTING, 2012, 38 : 2484 - 2490
  • [8] A SIMPLE METHOD FOR THE DETERMINATION OF GLUCOSE IN BLOOD
    SCHALES, O
    SCHALES, SS
    ARCHIVES OF BIOCHEMISTRY, 1945, 8 (02): : 285 - 292
  • [9] BLOOD-GLUCOSE DETERMINATION BY DEXTROSTIX-REFLECTANCE METER SYSTEM
    DRURY, MI
    SWEENEY, EC
    UACONAILL, D
    IRISH JOURNAL OF MEDICAL SCIENCE, 1972, 141 (10-1) : 181 - 186
  • [10] COMPARISON OF 5 REFLECTANCE METERS FOR CAPILLARY BLOOD-GLUCOSE DETERMINATION
    KOLOPP, M
    LOUIS, J
    POINTEL, JP
    KOHLER, F
    DROUIN, P
    DEBRY, G
    DIABETES & METABOLISM, 1983, 9 (01): : 19 - 25