Direct Reconstruction of CT-based Attenuation Correction Images for PET with Cluster-Based Penalties

被引:0
|
作者
Kim, Soo Mee [1 ]
Alessio, Adam M. [1 ]
De Man, Bruno [2 ]
Asma, Evren
Kinahan, Paul E. [1 ]
机构
[1] Univ Washington, Dept Radiol, Seattle, WA 98185 USA
[2] Gen Elect Global Res Ctr, Image Reconstruct Lab, Niskayuna, NY 12309 USA
关键词
SEGMENTATION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Extremely low-dose CT acquisitions for the purpose of PET attenuation correction will have a high level of noise and biasing artifacts due to factors such as photon starvation. This work explores a priori knowledge appropriate for CT iterative image reconstruction for PET attenuation correction. We investigate the maximum a posteriori (MAP) framework with cluster-based, multinomial priors for the direct reconstruction of the PET attenuation map. The objective function for direct iterative attenuation map reconstruction was modeled as a Poisson log-likelihood with prior terms consisting of quadratic (Q) and mixture (M) distributions. The attenuation map is assumed to have values in 4 clusters: air+background, lung, soft tissue, and bone. Under this assumption, the MP was a mixture probability density function consisting of one exponential and three Gaussian distributions. The relative proportion of each cluster was jointly estimated during each voxel update of direct iterative coordinate decent (dICD) method. Noise-free data were generated from NCAT phantom and Poisson noise was added. Reconstruction with FBP (ramp filter) was performed on the noise-free (ground truth) and noisy data. For the noisy data, dICD reconstruction was performed with the combination of different prior strength parameters (beta and gamma) of Q- and M-penalties. The combined quadratic and mixture penalties reduces the RMSE by 18.7% compared to post-smoothed iterative reconstruction and only 0.7% compared to quadratic alone. For direct PET attenuation map reconstruction from ultra-low dose CT acquisitions, the combination of quadratic and mixture priors offers regularization of both variance and bias and is a potential method to derive attenuation maps with negligible patient dose. However, the small improvement in quantitative accuracy relative to the substantial increase in algorithm complexity does not currently justify the use of mixture-based PET attenuation priors for reconstruction of CT images for PET attenuation correction.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Effect of chemoembolizing agents on the CT-based PET attenuation correction in dual-modality PET/CT
    Antoch, G
    Fronz, U
    Veit, P
    Freudenberg, LS
    Jentzen, W
    Brandau, W
    Bockisch, A
    Verhagen, R
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S331 - S331
  • [22] Contrast artifact correction in CT-based attenuation correction
    Chen, T.
    Lin, H. H.
    Chuang, K. S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S285 - S285
  • [23] A Comparison of CT-based Attenuation Correction Strategies for PET Data of Moving Structures
    Richter, Christian
    Hoinkis, Cordelia
    Just, Uwe
    Poenisch, Falk
    Woithe, Julia
    Enghardt, Wolfgang
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3919 - 3922
  • [24] Dosimetry and adequacy of CT-based attenuation correction for pediatric PET: Phantom study
    Fahey, Frederic H.
    Palmer, Matthew R.
    Strauss, Keith J.
    Zimmerman, Robert E.
    Badawi, Ramsey D.
    Treves, S. Ted
    RADIOLOGY, 2007, 243 (01) : 96 - 104
  • [25] Method for discrimination of contrast media in CT-based PET attenuation correction.
    Laymon, CM
    Carney, J
    Townsend, D
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 273P - 274P
  • [26] Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging
    David Izquierdo-Garcia
    Stephen J. Sawiak
    Karin Knesaurek
    Jagat Narula
    Valentin Fuster
    Joseph Machac
    Zahi A. Fayad
    European Journal of Nuclear Medicine and Molecular Imaging, 2014, 41 : 1574 - 1584
  • [27] Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging
    Izquierdo-Garcia, David
    Sawiak, Stephen J.
    Knesaurek, Karin
    Narula, Jagat
    Fuster, Valentin
    Machac, Joseph
    Fayad, Zahi A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 (08) : 1574 - 1584
  • [28] Comparison template-based with CT-based attenuation correction for hybrid MR/PET scanners
    Elena Rota Kops
    Hans Herzog
    N Jon Shah
    EJNMMI Physics, 1 (Suppl 1)
  • [29] Impact of Ge-68-based versus CT-based attenuation correction on PET imaging
    van Dalen, J. A.
    Visser, E. P.
    Vogel, W. V.
    Corstens, F. H. M.
    Oyen, W. J. G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S314 - S315
  • [30] Simulation-based Assessment of the Impact of Contrast Medium on CT-based Attenuation Correction in PET
    Ay, Mohamad Reza
    Zaidi, Habib
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2731 - 2735