Diagnostic Accuracy of the Neck Tornado Test as a New Screening Test in Cervical Radiculopathy

被引:2
|
作者
Park, Juyeon [1 ]
Park, Woo Young [2 ,3 ]
Hong, Seungbae [4 ]
An, Jiwon [5 ]
Koh, Jae Chul [6 ]
Lee, Youn-Woo [5 ]
Kim, Yong Chan [7 ]
Choi, Jong Bum [4 ]
机构
[1] Pusan Natl Univ, Yangsan Hosp, Dept Anesthesia & Pain Med, Pusan, South Korea
[2] Sheikh Khalifa Specialty Hosp, Dept Anesthesia, Ras Al Khaymah, U Arab Emirates
[3] Seoul Natl Univ, Coll Med, Dept Anesthesiol & Pain Med, Seoul, South Korea
[4] Ajou Univ, Coll Med, Dept Anesthesiol & Pain Med, 164 World Cup Ro, Suwon 16499, South Korea
[5] Yonsei Univ, Gangnam Severance Hosp, Coll Med, Dept Anesthesiol & Pain Med, Seoul, South Korea
[6] Korea Univ, Anam Hosp, Coll Med, Dept Anesthesiol & Pain Med, Seoul, South Korea
[7] Gwangmyeong Saeum Hosp, Dept Anesthesiol & Pain Med, Gwangmyeong, South Korea
来源
关键词
cervical radiculopathy; neck pain; radicular pain; Spurling test; neck tornado test; DISK DISEASE; MYELOGRAPHY; RELIABILITY; COMPRESSION; SPINE; ROOT;
D O I
10.7150/ijms.19110
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The Spurling test, although a highly specific provocative test of the cervical spine in cervical radiculopathy (CR), has low to moderate sensitivity. Thus, we introduced the neck tornado test (NTT) to examine the neck and the cervical spine in CR. Objectives: The aim of this study was to introduce a new provocative test, the NTT, and compare the diagnostic accuracy with a widely accepted provocative test, the Spurling test. Design: Retrospective study. Methods: Medical records of 135 subjects with neck pain (CR, n = 67; without CR, n = 68) who had undergone cervical spine magnetic resonance imaging and been referred to the pain clinic between September 2014 and August 2015 were reviewed. Both the Spurling test and NTT were performed in all patients by expert examiners. Sensitivity, specificity, and accuracy were compared for both the Spurling test and the NTT. Results: The sensitivity of the Spurling test and the NTT was 55.22% and 85.07% (P < 0.0001); specificity, 98.53% and 86.76% (P = 0.0026); accuracy, 77.04% and 85.93% (P = 0.0423), respectively. Conclusions: The NTT is more sensitive with superior diagnostic accuracy for CR diagnosed by magnetic resonance imaging than the Spurling test.
引用
收藏
页码:662 / 667
页数:6
相关论文
共 50 条
  • [41] Training sample selection: Impact on screening automation in diagnostic test accuracy reviews
    van Altena, Allard J.
    Spijker, Rene
    Leeflang, Mariska M. G.
    Olabarriaga, Silvia Delgado
    RESEARCH SYNTHESIS METHODS, 2021, 12 (06) : 831 - 841
  • [42] Diagnostic Accuracy of the AzBio in Noise Test
    Vermiglio, Andrew J.
    Leclerc, Lauren
    Thornton, Meagan
    Osborne, Hannah
    Bonilla, Elizabeth
    Fang, Xiangming
    JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH, 2021, 64 (08): : 3303 - 3316
  • [43] Introduction to diagnostic test accuracy studies
    Sitch, Alice J.
    Dekkers, Olaf M.
    Scholefield, Barnaby R.
    Takwoingi, Yemisi
    EUROPEAN JOURNAL OF ENDOCRINOLOGY, 2021, 184 (02) : E5 - E9
  • [44] Systematic Reviews of Diagnostic Test Accuracy
    Leeflang, Mariska M. G.
    Deeks, Jonathan J.
    Gatsonis, Constantine
    Bossuyt, Patrick M. M.
    ANNALS OF INTERNAL MEDICINE, 2008, 149 (12) : 889 - +
  • [45] Interpreting diagnostic test accuracy studies
    Bossuyt, Patrick M. M.
    SEMINARS IN HEMATOLOGY, 2008, 45 (03) : 189 - 195
  • [46] Quantifying the Accuracy of a Diagnostic Test or Marker
    Linnet, Kristian
    Bossuyt, Patrick M. M.
    Moons, Karel G. M.
    Reitsma, Johannes B. R.
    CLINICAL CHEMISTRY, 2012, 58 (09) : 1292 - 1301
  • [47] DIAGNOSTIC ACCURACY OF NITROBLUE TETRAZOLIUM TEST
    SOONATTRAKUL, W
    ANDERSEN, BR
    ARCHIVES OF INTERNAL MEDICINE, 1973, 132 (04) : 529 - 532
  • [48] MICHIGAN ALCOHOLISM SCREENING TEST - QUEST FOR A NEW DIAGNOSTIC INSTRUMENT
    SELZER, ML
    AMERICAN JOURNAL OF PSYCHIATRY, 1971, 127 (12): : 1653 - &
  • [49] Smooth pursuit neck torsion test: A specific test for cervical dizziness
    Tjell, C
    Rosenhall, U
    AMERICAN JOURNAL OF OTOLOGY, 1998, 19 (01): : 76 - 81
  • [50] A methodological framework to distinguish spectrum effects from spectrum biases and to assess diagnostic and screening test accuracy for patient populations: Application to the Papanicolaou cervical cancer smear test
    Elie, Caroline
    Coste, Joel
    BMC MEDICAL RESEARCH METHODOLOGY, 2008, 8 (1)