共 50 条
Comparison of cardiac computed tomography angiography and transoesophagea echocardiography for device surveillance after left atrial appendage closure
被引:72
|作者:
Qamar, Sadia R.
[1
]
Jalal, Sabeena
[1
]
Nicolaou, Savvas
[1
]
Tsang, Michael
[2
]
Gilhofer, Thomas
[2
]
Saw, Jacqueline
[2
]
机构:
[1] Univ British Columbia, Vancouver Gen Hosp, Dept Radiol, Vancouver, BC, Canada
[2] Univ British Columbia, Vancouver Gen Hosp, Dept Cardiol, Vancouver, BC, Canada
基金:
美国国家卫生研究院;
加拿大健康研究院;
关键词:
atrial fibrillation;
LAA closure;
MSCT;
other imaging modalities;
CLINICAL IMPACT;
FIBRILLATION;
OBLITERATION;
STROKE;
ANTICOAGULATION;
WATCHMAN;
CT;
D O I:
10.4244/EIJ-D-18-01107
中图分类号:
R5 [内科学];
学科分类号:
1002 ;
100201 ;
摘要:
Aims: Device surveillance after left atrial appendage (LAA) closure (LAAC) is important to assess device positioning, peri-device leak (PDL) and device-related thrombus (DRT). There are limited data on the role of cardiac CT angiography (CCTA) after LAAC. We therefore sought to compare CCTA to trans-oesophagealechocardiography (TEE) in patients who successfully underwent LAAC. Methods and results: We report our consecutive series of non-valvular atrial fibrillation patients who underwent LAAC and had CCTA and TEE post LAAC. Prospective cardiac-gated CCTA was performed with the Toshiba 320-detector or Siemens second-generation 128-slice dual-source scanner, and post-processingwas performed with IMPAX 3D reformats. Glomerular filtration rate <30 mL/min/1.73 m(2) was an exclusion for CCTA. Device positioning, PDL or fabric leak, ratio of left atrial (LA) to LAA linear attenuation coefficient, and DRT were analysed. One hundred and two patients underwent LAAC (79 WATCHMAN,17 Amulet, 6 ACP). Mean age was 76.4 +/- 7.5 years, CHADS2 score 3.0 +/- 1.3, and CHADS-VASc score 4.6 +/- 1.6. CCTA was performed at a mean of 105.2 +/- 54.8 days, and TEE at a mean of 124.9 +/- 100.3 days post LAAC. LAA patency was observed in 52/100 (52%), with 45 (86.5%) via PDL and seven (13.5%) through fabric leak. Linear attenuation coefficient <100 HU and LA:LAA ratio <0.25 were seen in occluded devices. PDL was only observed in 35/102 (34.3%) on TEE. Mean device compression was greater with sealed devices (11.3 +/- 4.3% versus 8.2 +/- 4.0%, p<0.001). There was only one DRT, which was observed on both TEE and CCTA. Conclusions: CCTA is a suitable alternative to TEE for device surveillance post LAAC. CCTA was more sensitive than TEE for assessing PDL and can delineate the cause of residual LAA contrast patency.
引用
收藏
页码:663 / +
页数:10
相关论文