A silicon IR-source and CO2-chamber for Co2 measurements

被引:4
|
作者
Kalvesten, E [1 ]
Corman, T [1 ]
Huiku, M [1 ]
Weckstrom, K [1 ]
Merilainen, P [1 ]
Stemme, G [1 ]
机构
[1] Royal Inst Technol, Dep Signals Sensors & Syst, S-10044 Stockholm, Sweden
关键词
D O I
10.1109/MEMSYS.1998.659731
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
For the first time a silicon IR-source and CO2-chamber system for measurement of CO2 concentration is presented. This new miniaturized infrared sensor is specially designed for the measurement of respiratory gases present in patient airways during anesthesia or intensive care. The IR-sensor assembly consists of an IR-source chip with two pairs of diagonally arranged IR-sources for the generation of two switched "sample" and reference beams. The gas filter chip is arranged with two CO2 chambers directly beneath the two reference sources. These chambers "pre-absorb" the reference beam at the CO2 wavelength band around 4.26 mu m. The reference beam is needed for long term stability and for compensation against cuvette window contamination. The electrically modulated IR-sources consist of incandescent polysilicon filaments coated with silicon nitride across a 220 mu m deep cavity. The CO2-chambers with a length of 1 mm are fabricated by silicon fusion and anodic bonding at a chosen CO2 pressure for optimal filter characteristics. Test measurements of the infrared sensor system show high CO2-sensitivity meaning that the stringent requirements for this respirator application can be reached.
引用
收藏
页码:69 / 74
页数:4
相关论文
共 50 条
  • [31] IR CO2 SENSOR FOR ASTRONAUT SAFETY
    TULLOCH, MH
    PHOTONICS SPECTRA, 1993, 27 (07) : 20 - +
  • [32] CO2 Absorption of IR Radiated by the Earth
    J Chem Educ, 3 (316):
  • [33] CO2 absorption of IR radiated by the earth
    Natural Sciences Division, University of Pittsburgh at Bradford, Bradford, PA 16701, United States
    J Chem Educ, 3 (316-317):
  • [34] Density Measurements of Supercritical CO2 + Dagang Brine for CO2 Geological Storage
    Zhang, Yi
    Shen, Yong
    Song, Yongchen
    Zhan, Yangchun
    Nishio, Masahiro
    Jian, Weiwei
    Xing, Wanli
    Hu, Cheng
    GHGT-11, 2013, 37 : 5620 - 5627
  • [35] RAYLEIGH MEASUREMENTS IN A CO2 JET
    LEIPERTZ, A
    APPLIED OPTICS, 1982, 21 (16): : 2872 - 2874
  • [36] Expanding role of CO2 measurements
    Bearg, David W.
    Engineered Systems, 1994, 11 (02):
  • [37] Aspects of CO2 advection measurements
    Lukas Siebicke
    Martina Hunner
    Thomas Foken
    Theoretical and Applied Climatology, 2012, 109 : 109 - 131
  • [38] Aspects of CO2 advection measurements
    Siebicke, Lukas
    Hunner, Martina
    Foken, Thomas
    THEORETICAL AND APPLIED CLIMATOLOGY, 2012, 109 (1-2) : 109 - 131
  • [39] BLOOD CO2 AND PH MEASUREMENTS
    COMROE, JH
    METHODS IN MEDICAL RESEARCH, 1950, 2 (02) : 178 - 180
  • [40] To CO2 or not to CO2 ,that is the question!
    Hohnadel, DC
    Gruttadauria, M
    Murray, K
    Levin, M
    D'Souza, J
    CLINICAL CHEMISTRY, 2003, 49 (06) : A90 - A90