Prostate brachytherapy seed identification on post-implant TRUS images

被引:78
|
作者
Han, BH
Wallner, K
Merrick, G
Butler, W
Sutlief, S
Sylvester, J
机构
[1] Vet Affairs Med Ctr, Puget Sound Hlth Care Syst, Seattle, WA 98108 USA
[2] Univ Washington, Dept Radiat Oncol, Seattle, WA 98108 USA
[3] Grp Hlth Cooperat Puget Sound, Seattle, WA 98121 USA
[4] Schiffler Canc Ctr, Wheeling, WV USA
[5] Seattle Prostate Inst, Seattle, WA USA
关键词
prostate cancer; brachytherapy; TRUS;
D O I
10.1118/1.1568976
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
TRUS is a conceptually appealing alternative to CT based dosimetry, offering the substantial practical advantage of being readily available intraoperatively. To test the feasibility and reliability of seed identification on post-implant TRUS using standard two-dimensional images, ten patients treated with I-125 or Pd-103 brachytherapy were studied. A set of transverse images (6 MHz) were taken immediately following completion of the implant procedure. Original thermal images were sent to four physicians and the sources were identified independently by placing marks on a cellophane overlay, with grids to match the axial TRUS images. The number and type of seed implanted were not revealed to the investigators, Instead, they were instructed to mark the positions of what they would consider, with reasonable certainty, to be seeds. The overlays were then manually compared for source identification and agreement between observers regarding each alleged source. The actual number of implanted seeds ranged from 44 to (08 (median: 60). In contrast, the mean number of seeds allegedly identified per patients ranged from 26 to 82 (median: 43). The average percent of the seeds allegedly identified per patient ranged from 51% to 83% (mean: 74%). The four physician investigators-KW, JS, BH, and GM-identified an alleged median of 90%, 44%, 63%, and 91% of the total seeds, respectively. There were five instances in which investigators alleged more seeds than were actually implanted. The consistency of seed identification among the investigators was evaluated by noting how many investigators identified each bright spot on the images. The percent of bright spots identified by all four investigators ranged from 8% to 33% (median: 20%). Despite considerable interest among some of our clinical and commercial colleagues in developing TRUS-based intraoperative post-implant dosimetry, the use of TRUS-based seed identification for post-implant dosimetry should be viewed with skepticism. (C) 2003 American Association of Physicists in Medicine.
引用
收藏
页码:898 / 900
页数:3
相关论文
共 50 条
  • [21] Accounting for Prostate Motion in Interstitial Prostate LDR Brachytherapy for Aiding Post-Implant Dosimetry
    Gulam, M.
    Gopal, A.
    Pradhan, D.
    Smith, C.
    Nurushev, T.
    Chetty, I.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [22] Investigation to Replace CT by MRI in Post-Implant Dosimetry of Prostate Permanent Brachytherapy
    Chen, Q.
    Blair, H.
    Ciezki, J.
    Mahadevan, A.
    Began, N.
    Suh, J.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [23] Post-Implant Dosimetry in Prostate Brachytherapy by X-Ray and MRI Fusion
    Park, S.
    Le, Y.
    Song, D.
    Lee, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3794 - 3794
  • [24] Predictive factors for post-implant dosimetric outcomes in transperineal permanent prostate brachytherapy
    Meier, R
    Grimm, PD
    Sylvester, JE
    Blasko, JC
    RADIOLOGY, 2002, 225 : 266 - 266
  • [25] Evaluation of Post-Implant Dosimetry in LDR Permanent Interstitial Brachytherapy for Prostate Cancer
    Khouj, Y.
    Harris, T.
    O'Farrell, D.
    Sugar, E. Neubauer
    Nguyen, P.
    Orio, P.
    King, M.
    Buzurovic, I.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [26] Comparison of post-implant dosimetry parameters for I-125 seed prostate brachytherapy determined using MR plus CT images versus CT images alone
    Alexander, A.
    Sloboda, R.
    Pedersen, J.
    Danielson, B.
    Murtha, A.
    Yee, D.
    Pervez, N.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S68 - S68
  • [27] Dosimetric effects of prone and supine positions on post-implant assessments for prostate brachytherapy
    Ohashi, Toshio
    Momma, Tetsuo
    Yamashita, Shoji
    Kanai, Kunimitsu
    Watanabe, Yusuke
    Hanada, Takashi
    Shigematsu, Naoyuki
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2013, 5 (03) : 122 - 126
  • [28] A COMPARISON OF POST-IMPLANT US/CT IMAGE FUSION AND MRI/CT FUSION FOR I-125 PROSTATE BRACHYTHERAPY POST-IMPLANT DOSIMETRY
    Patanjali, N.
    Keyes, M.
    Morris, J.
    Liu, M.
    Harrison, R.
    Spadinger, I.
    Moravan, V.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S40 - S40
  • [29] TrueFISP for Single Sequence MR-Only Post-Implant Dosimetry of Prostate Brachytherapy
    Sanders, J.
    Frank, S.
    Venkatesan, A.
    Bathala, T.
    Szklaruk, J.
    Blanchard, P.
    Kudchadker, R.
    Ma, J.
    MEDICAL PHYSICS, 2017, 44 (06) : 3049 - 3049
  • [30] Organ contouring in permanent prostate brachytherapy (PPB) post-implant evaluation: a multicentric study
    Di Muzio, N
    Lavagnini, P
    Fellin, G
    Vavassori, A
    Del Duca, D
    Mangili, P
    Longobardi, B
    RADIOTHERAPY AND ONCOLOGY, 2004, 71 : S123 - S123