Prostate brachytherapy seed identification on post-implant TRUS images

被引:78
|
作者
Han, BH
Wallner, K
Merrick, G
Butler, W
Sutlief, S
Sylvester, J
机构
[1] Vet Affairs Med Ctr, Puget Sound Hlth Care Syst, Seattle, WA 98108 USA
[2] Univ Washington, Dept Radiat Oncol, Seattle, WA 98108 USA
[3] Grp Hlth Cooperat Puget Sound, Seattle, WA 98121 USA
[4] Schiffler Canc Ctr, Wheeling, WV USA
[5] Seattle Prostate Inst, Seattle, WA USA
关键词
prostate cancer; brachytherapy; TRUS;
D O I
10.1118/1.1568976
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
TRUS is a conceptually appealing alternative to CT based dosimetry, offering the substantial practical advantage of being readily available intraoperatively. To test the feasibility and reliability of seed identification on post-implant TRUS using standard two-dimensional images, ten patients treated with I-125 or Pd-103 brachytherapy were studied. A set of transverse images (6 MHz) were taken immediately following completion of the implant procedure. Original thermal images were sent to four physicians and the sources were identified independently by placing marks on a cellophane overlay, with grids to match the axial TRUS images. The number and type of seed implanted were not revealed to the investigators, Instead, they were instructed to mark the positions of what they would consider, with reasonable certainty, to be seeds. The overlays were then manually compared for source identification and agreement between observers regarding each alleged source. The actual number of implanted seeds ranged from 44 to (08 (median: 60). In contrast, the mean number of seeds allegedly identified per patients ranged from 26 to 82 (median: 43). The average percent of the seeds allegedly identified per patient ranged from 51% to 83% (mean: 74%). The four physician investigators-KW, JS, BH, and GM-identified an alleged median of 90%, 44%, 63%, and 91% of the total seeds, respectively. There were five instances in which investigators alleged more seeds than were actually implanted. The consistency of seed identification among the investigators was evaluated by noting how many investigators identified each bright spot on the images. The percent of bright spots identified by all four investigators ranged from 8% to 33% (median: 20%). Despite considerable interest among some of our clinical and commercial colleagues in developing TRUS-based intraoperative post-implant dosimetry, the use of TRUS-based seed identification for post-implant dosimetry should be viewed with skepticism. (C) 2003 American Association of Physicists in Medicine.
引用
收藏
页码:898 / 900
页数:3
相关论文
共 50 条
  • [1] Effects of seed migration on post-implant dosimetry of prostate brachytherapy
    Gao, M.
    Wang, J. Z.
    Nag, S.
    Gupta, N.
    MEDICAL PHYSICS, 2007, 34 (02) : 471 - 480
  • [2] Impact of Seed Localization On Post-Implant Dosimetry in Prostate Brachytherapy
    Chew, M.
    Xue, J.
    Houser, C.
    Misic, V.
    Cao, J.
    Cornwell, T.
    Yu, Y.
    Gressen, E.
    Handler, J.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [3] A Template Based Approach for Automatic Seed Detection in Post-implant CT Images for Prostate Brachytherapy
    Yazdi, Mehran
    GhadarGhadr, Shabnam
    Beaulieu, Luc
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3205 - 3208
  • [4] Seed-displacements in the immediate post-implant phase in permanent prostate brachytherapy
    Karius, Andre
    Schweizer, Claudia
    Strnad, Vratislav
    Lotter, Michael
    Kreppner, Stephan
    Lamrani, Allison
    Fietkau, Rainer
    Bert, Christoph
    RADIOTHERAPY AND ONCOLOGY, 2023, 183
  • [5] COMPARISON OF TWO PERMANENT PROSTATE SEED IMPLANT BRACHYTHERAPY TECHNIQUES - INCLUDING POST-IMPLANT EVALUATION
    Andersen, K.
    Geertsen, P. F.
    Kristensen, B. Holch
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S159 - S160
  • [6] Feasibility of TRUS-based prostate post-implant dosimetry
    Xue, J
    Gressen, E
    MEDICAL PHYSICS, 2004, 31 (06) : 1718 - 1718
  • [7] Importance of post-implant dosimetry in permanent prostate brachytherapy
    Stock, RG
    Stone, NN
    EUROPEAN UROLOGY, 2002, 41 (04) : 434 - 439
  • [8] A post-implant dosimetry simulator for permanent breast seed implant brachytherapy
    Zhang, Claire
    Batchelar, Deidre
    Andrews, Jeff
    Crook, Juanita
    Hilts, Michelle
    MEDICAL PHYSICS, 2022, 49 (08) : 5700 - 5701
  • [9] Automated "prostate-only" registration of CT/MR images for post-implant dosimetric assessment of permanent seed brachytherapy
    Sloboda, R.
    MEDICAL PHYSICS, 2007, 34 (06) : 2421 - 2421
  • [10] Effect of post-implant edema on prostate brachytherapy treatment margins
    Reed, DR
    Wallner, K
    Ford, E
    Mueller, A
    Merrick, G
    Maki, J
    Sutlief, S
    Butler, W
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (05): : 1469 - 1473