Stable isotope-assisted LC-MS/MS monitoring of glyceryl trinitrate bioactivation in a cell culture model of nitrate tolerance

被引:8
|
作者
Axton, Elizabeth R. [1 ,2 ,3 ]
Hardardt, Elizabeth A. [1 ,3 ]
Stevens, Jan F. [1 ,3 ]
机构
[1] Oregon State Univ, Linus Pauling Inst, Corvallis, OR 97331 USA
[2] Oregon State Univ, Dept Environm & Mol Toxicol, Corvallis, OR 97331 USA
[3] Oregon State Univ, Dept Pharmaceut Sci, Corvallis, OR 97331 USA
关键词
Nitrite; Nitric oxide; Nitrate tolerance; LC-MS/MS; Glyceryl trinitrate; Cell culture; PERFORMANCE LIQUID-CHROMATOGRAPHY; NITRIC-OXIDE METABOLITES; XANTHINE OXIDOREDUCTASE; BIOLOGICAL SAMPLES; FLUORESCENCE DETECTION; S-NITROSOTHIOLS; REDUCTION; GENERATION; FLUIDS; ASSAY;
D O I
10.1016/j.jchromb.2015.12.010
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The nitric oxide (NO) metabolites nitrite (NO2-) and nitrate (NO3-) can be quantified as an endpoint of endothelial function. We developed a LC-MS/MS method of measuring nitrite and nitrate isotopologues, which has a lower limit of quantification (LLOQ) of 1 nM. This method allows for isotopic labeling to differentiate newly formed nitrite and nitrate from nanomolar to micromolar background levels of nitrite and nitrate in biological matrices. This method utilizes 2,3-diaminonaphthalene (DAN) derivatization, which reacts with nitrite under acidic conditions to produce 2,3-naphthotriazole (NAT). NAT was chromatographically separated on a Shimadzu LC System with an Agilent Extend-C-18 5 mu m 2.1 x 150 mm column and detected using a multiple reaction monitoring (MRM) method on an ABSciex 3200 QTRAP mass spectrometer operated in positive mode. Mass spectrometry allows for the quantification of N-14-NAT (m/z 170.1) and N-15-NAT (m/z 171.1). Both nitrite and nitrate demonstrated a linear detector response (1 nM -10 mu M, 1 nM -100 nM, respectively), and were unaffected by common interferences (Dulbecco's Modified Eagle Medium (DMEM), fetal bovine serum (FBS), phenol red, and NADPH). This method requires minimal sample preparation, making it ideal for most biological applications. We applied this method to develop a cell culture model to study the development of nitrate tolerance in human endothelial cells (EA.hy926). (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:156 / 163
页数:8
相关论文
共 50 条
  • [11] Determination of triazines and degradates in water using LC-MS/MS and stable isotope analogs as internal standard
    Chen, Sunmao
    Merritt, Andrew
    Huang, Sung-Ben
    Mayer, Louis
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2012, 244
  • [12] Development of a Stable Isotope Dilution LC-MS/MS Method for the Alternaria Toxins Tentoxin, Dihydrotentoxin, and Isotentoxin
    Liu, Yang
    Rychlik, Michael
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2013, 61 (12) : 2970 - 2978
  • [13] A Stable Isotope Dilution Assay for Multi-class Antibiotics in Pregnant Urines by LC-MS/MS
    Liu, Kai-yong
    Zhang, Jing-jing
    Geng, Meng-long
    Zhu, Yi-tian
    Liu, Xin-ji
    Ding, Peng
    Wang, Bao-lin
    Liu, Wen-wen
    Liu, Ye-hao
    Tao, Fang-biao
    CHROMATOGRAPHIA, 2020, 83 (04) : 507 - 521
  • [14] Multi-mycotoxin stable isotope dilution LC-MS/MS method for Fusarium toxins in cereals
    Katharina Habler
    Michael Rychlik
    Analytical and Bioanalytical Chemistry, 2016, 408 : 307 - 317
  • [15] Multi-mycotoxin stable isotope dilution LC-MS/MS method for Fusarium toxins in cereals
    Habler, Katharina
    Rychlik, Michael
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (01) : 307 - 317
  • [16] Stable deuterium internal standard for the isotope-dilution LC-MS/MS analysis of elastin degradation
    Ma, Shuren
    Turino, Gerard M.
    Hayashi, Takahiro
    Yanuma, Hiroto
    Usuki, Toyonobu
    Lin, Yong Y.
    ANALYTICAL BIOCHEMISTRY, 2013, 440 (02) : 158 - 165
  • [17] An LC-MS/MS method for stable isotope dilution studies of γ-carotene bioefficacy and vitamin A status in humans
    Oxley, Anthony
    Berry, Philip
    Cowell, Joseph
    Hall, Michael
    Hesketh, John
    Lietz, Georg
    Boddy, Alan V.
    PROCEEDINGS OF THE NUTRITION SOCIETY, 2013, 72 (OCE4) : E301 - E301
  • [18] Risk screening of mycotoxins and their derivatives in dairy products using a stable isotope dilution assay and LC-MS/MS
    Yang, Shuai
    Luo, Yunjing
    Mu, Lei
    Yang, Youyou
    Yang, Yongtan
    JOURNAL OF SEPARATION SCIENCE, 2021, 44 (04) : 782 - 792
  • [19] Evaluation of a cleavable stable isotope labeled synthetic peptide for absolute protein quantification using LC-MS/MS
    Barnidge, DR
    Hall, GD
    Stocker, JL
    Muddiman, DC
    JOURNAL OF PROTEOME RESEARCH, 2004, 3 (03) : 658 - 661
  • [20] Development of Stable Isotope Dilution Assays for the Simultaneous Quantitation of Biogenic Amines and Polyamines in Foods by LC-MS/MS
    Mayr, Christine M.
    Schieberle, Peter
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2012, 60 (12) : 3026 - 3032