Biomechanical properties of a suture anchor system from human allogenic mineralized cortical bone matrix for rotator cuff repair

被引:5
|
作者
Schanda, Jakob E. [1 ,2 ,3 ,4 ]
Obermayer-Pietsch, Barbara [5 ]
Sommer, Gerhard [6 ]
Heuberer, Philipp R. [7 ,8 ]
Laky, Brenda [8 ]
Muschitz, Christian [9 ]
Pastl, Klaus [10 ]
Pastl, Eva [10 ]
Fialka, Christian [1 ,11 ]
Mittermayr, Rainer [1 ,2 ,3 ]
Grillari, Johannes [2 ,3 ,12 ]
Foessl, Ines [4 ]
机构
[1] AUVATrauma Ctr Vienna Meidling, Dept Trauma Surg, Vienna, Austria
[2] Res Ctr Cooperat AUVA, Ludwig Boltzmann Inst Traumatol, Vienna, Austria
[3] Austrian Cluster Tissue Regenerat, Vienna, Austria
[4] Michael Ogon Lab Orthopaed Res, Vienna, Austria
[5] Med Univ Graz, Dept Internal Med, Div Endocrinol & Diabetol, Graz, Austria
[6] Graz Univ Technol, Inst Biomech, Graz, Austria
[7] HealthPi Med Ctr, Vienna, Austria
[8] Austrian Res Grp Regenerat & Orthoped Med AURROM, Vienna, Austria
[9] St Vincent Hosp Vienna, Med Dept 2, Vienna, Austria
[10] Surgebright GmbH, Lichtenberg, Austria
[11] Sigmund Freud Med Univ Vienna, Dept Traumatol, Vienna, Austria
[12] Univ Nat Resources & Life Sci BOKU, Inst Mol Biotechnol, Dept Biotechnol, Vienna, Austria
关键词
Shoulder; Shoulder surgery; Rotator cuff reconstruction; Suture anchor; Allogenic mineralized suture anchor; Biomechanical analysis; High-resolution peripheral quantitative computed tomography; SHOULDER SURGERY; PULLOUT STRENGTH; ARTHROSCOPIC REPAIR; OSTEOPOROTIC BONE; FOLLOW-UP; FIXATION; TENDON; COMPLICATIONS; FAILURE; TRANSPLANTS;
D O I
10.1186/s12891-022-05371-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Suture anchors (SAs) made of human allogenic mineralized cortical bone matrix are among the newest developments in orthopaedic and trauma surgery. Biomechanical properties of an allogenic mineralized suture anchor (AMSA) are not investigated until now. The primary objective was the biomechanical investigation of AMSA and comparing it to a metallic suture anchor (MSA) and a bioabsorbable suture anchor (BSA) placed at the greater tuberosity of the humeral head of cadaver humeri. Additionally, we assessed the biomechanical properties of the SAs with bone microarchitecture parameters. Methods First, bone microarchitecture of 12 fresh frozen human cadaver humeri from six donors was analyzed by high-resolution peripheral quantitative computed tomography. In total, 18 AMSAs, 9 MSAs, and 9 BSAs were implanted at a 60 degrees angle. All three SA systems were systematically implanted alternating in three positions within the greater tuberosity (position 1: anterior, position 2: central, position 3: posterior) with a distance of 15 mm to each other. Biomechanical load to failure was measured in a uniaxial direction at 135 degrees. Results Mean age of all specimens was 53.6 +/- 9.1 years. For all bone microarchitecture measurements, linear regression slope estimates were negative which implies decreasing values with increasing age of specimens. Positioning of all three SA systems at the greater tuberosity was equally distributed (p = 0.827). Mean load to failure rates were higher for AMSA compared to MSA and BSA without reaching statistical significance between the groups (p = 0.427). Anchor displacement was comparable for all three SA systems, while there were significant differences regarding failure mode between all three SA systems (p < 0.001). Maximum load to failure was reached in all cases for AMSA, in 44.4% for MSA, and in 55.6% for BSA. Suture tear was observed in 55.6% for MSA and in 22.2% for BSA. Anchor breakage was solely seen for BSA (22.2%). No correlations were observed between bone microarchitecture parameters and load to failure rates of all three suture anchor systems. Conclusions The AMSA showed promising biomechanical properties for initial fixation strength for RCR. Since reduced BMD is an important issue for patients with chronic rotator cuff lesions, the AMSA is an interesting alternative to MSA and BSA. Also, the AMSA could improve healing of the enthesis.
引用
收藏
页数:9
相关论文
共 43 条
  • [31] Cement Augmentation of Suture Anchor During Arthroscopic Rotator Cuff Repair in Case of Proximal Humeral Bone Deficiency Due to Osteoporosis
    Al Thani, Saeed
    Meshram, Prashant
    [J]. ARTHROSCOPY TECHNIQUES, 2023, 12 (06): : E897 - E902
  • [32] Suture anchor fixation strength with or without augmentation in osteopenic and severely osteoporotic bones in rotator cuff repair: a biomechanical study on polyurethane foam model
    Mehmet Serhan Er
    Levent Altinel
    Mehmet Eroglu
    Ozgur Verim
    Teyfik Demir
    Halil Atmaca
    [J]. Journal of Orthopaedic Surgery and Research, 9
  • [33] Suture anchor fixation strength with or without augmentation in osteopenic and severely osteoporotic bones in rotator cuff repair: a biomechanical study on polyurethane foam model
    Er, Mehmet Serhan
    Altinel, Levent
    Eroglu, Mehmet
    Verim, Ozgur
    Demir, Teyfik
    Atmaca, Halil
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2014, 9 : 1 - 7
  • [34] Cortical suspensory button fixation has superior biomechanical properties to knotless anchor suture in anterior cruciate ligament repair: a biomechanical study
    Itthipanichpong, Thun
    Thamrongskulsiri, Napatpong
    Tangpornprasert, Pairat
    Virulsri, Chanyaphan
    Limskul, Danaithep
    Kuptniratsaikul, Somsak
    Tanpowpong, Thanathep
    [J]. SCIENTIFIC REPORTS, 2023, 13 (01)
  • [35] Cortical suspensory button fixation has superior biomechanical properties to knotless anchor suture in anterior cruciate ligament repair: a biomechanical study
    Thun Itthipanichpong
    Napatpong Thamrongskulsiri
    Pairat Tangpornprasert
    Chanyaphan Virulsri
    Danaithep Limskul
    Somsak Kuptniratsaikul
    Thanathep Tanpowpong
    [J]. Scientific Reports, 13
  • [36] Effect of pretension and suture needle type on mechanical properties of acellular human dermis patches for rotator cuff repair
    Sahoo, Sambit
    Greeson, Clay B.
    McCarron, Jesse A.
    Milks, Ryan A.
    Aurora, Amit
    Walker, Esteban
    Iannotti, Joseph P.
    Derwin, Kathleen A.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (10) : 1413 - 1421
  • [37] Zoledronic Acid Substantially Improves Bone Microarchitecture and Biomechanical Properties After Rotator Cuff Repair in a Rodent Chronic Defect Model
    Schanda, Jakob E.
    Keibl, Claudia
    Heimel, Patrick
    Monforte, Xavier
    Tangl, Stefan
    Feichtinger, Xaver
    Teuschl, Andreas H.
    Baierl, Andreas
    Muschitz, Christian
    Redl, Heinz
    Fialka, Christian
    Mittermayr, Rainer
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2020, 48 (09): : 2151 - 2160
  • [38] Biomechanical comparison of double-row versus transtendon single-row suture anchor technique for repair of the grade Ⅲ partial articular-sided rotator cuff tears
    ZHANG ChungangZHAO DeweiWANG WeimingREN Mingfa LI RuixinYANG Sheng and LIU Yupeng Department of OrthopedicsAffiliated Zhongshan Hospital of Dalian UniversityDalianLiaoning China State Key Laboratory of Structural Analysis for Industrial EquipmentDalian University of TechnologyDalianLiaoning China
    [J]. 中华医学杂志(英文版), 2010, (21) : 3049 - 3054
  • [39] Anchor design and bone mineral density affect the pull-out strength of suture anchors in rotator cuff repair - Which anchors are best to use in patients with low bone quality?
    Tingart, MJ
    Apreleva, M
    Lehtinen, J
    Zurakowski, D
    Warner, JJP
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2004, 32 (06): : 1466 - 1473
  • [40] Biomechanical comparison of double-row versus transtendon single-row suture anchor technique for repair of the grade III partial articular-sided rotator cuff tears
    Zhang Chun-gang
    Zhao De-wei
    Wang Wei-ming
    Ren Ming-fa
    Li Rui-xin
    Yang Sheng
    Liu Yu-peng
    [J]. CHINESE MEDICAL JOURNAL, 2010, 123 (21) : 3049 - 3054