Design of an ion extractor system for a prototype ion source experiment for SST-1 neutral beam injector

被引:4
|
作者
Jana, M. R. [1 ]
Bandyopadhaya, M. [1 ]
Singh, N. P. [1 ]
Sharma, S. K. [1 ]
Chakraborty, A. K. [1 ]
Baruah, U. K. [1 ]
Mattoo, S. K. [1 ]
机构
[1] Inst Plasma Res, Gandhinagar 382428, Gujarat, India
关键词
Ion source; Extraction system; Neutral beam injector; SST-1;
D O I
10.1016/j.fusengdes.2009.08.004
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
An ion extractor system has been designed for the steady state superconducting tokamak (SST-I) neutral beam injector (NBI) for an experiment using a prototype ion source with fully integrated regulated high voltage power Supply (RHVPS) and data acquisition and control system (DACS) developed at Institute for Plasma Research (IPR) to obtain experience of NB operation. The extractor system is capable of extracting positive hydrogen ion beam of similar to 10 A current at similar to 20 W This paper presents the beam optics study for detailed design of an ion extraction system which could meet this requirement. It consists of 3 grid accel-decel system, each of the grid has 217 straight cylindrical holes of 8 mm diameter. Grids are placed on a specially designed G-10 block; a fiber reinforc plastic (FRP) isolator of outer diameter of 820 mm and 50mm thickness. Provisions are made for supplying high voltage to the grid system through the embedded feed-throughs. Extractor system has been fabricated, mounted on the SST-1 neutral beam injector and has extracted positive hydrogen ion beam of 4 A at 20 W till now. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:122 / 125
页数:4
相关论文
共 50 条
  • [41] Cavity Ringdown Technique for negative-hydrogen-ion measurement in ion source for neutral beam injector
    Nakano, H.
    Tsumori, K.
    Shibuya, M.
    Geng, S.
    Kisaki, M.
    Ikeda, K.
    Nagaoka, K.
    Osakabe, M.
    Takeiri, Y.
    Kaneko, O.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [42] Analysis of Energy Deposition on Ion Source Components of EAST Neutral Beam Injector
    Li, Xiang
    Xu, Yongjian
    Hu, Chundong
    Yu, Ling
    Chen, Yu
    FUSION SCIENCE AND TECHNOLOGY, 2016, 70 (03) : 429 - 434
  • [43] ION EXTRACTOR SYSTEM DESIGN
    STAGGS, JF
    RICHLEY, EA
    GULA, WP
    AIAA JOURNAL, 1967, 5 (02) : 359 - &
  • [44] Study on an azimuthal line cusp ion source for the KSTAR neutral beam injector
    Jeong, Seung Ho
    Chang, Doo-Hee
    In, Sang Ryul
    Lee, Kwang Won
    Oh, Byung-Hoon
    Yoon, Byung-Joo
    Song, Woo Sob
    Kim, Jinchoon
    Kim, Tae Seong
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (02):
  • [45] Design and development of distributed control system for SST-1 Thomson scattering experiment
    Chaudhari, V.
    Patel, K.
    Srivastava, A.
    Thomas, J.
    Kumar, A.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [46] Design of power supply system for the prototype RF-driven negative ion source for neutral beam injection application
    Jiang, Caichao
    Hu, Chundong
    Wei, Jianglong
    Xie, Yahong
    Xu, Yongjian
    Liang, Lizhen
    Chen, Shiyong
    Liu, Sheng
    Liu, Zhimin
    Xie, Yuanlai
    FUSION ENGINEERING AND DESIGN, 2017, 117 : 100 - 106
  • [47] Design of a cooling system for the ITER Ion Source and Neutral Beam test facilities
    Dalla Palma, M.
    Dal Bello, S.
    Fellin, F.
    Zaccaria, P.
    FUSION ENGINEERING AND DESIGN, 2009, 84 (7-11) : 1460 - 1464
  • [48] DESIGN STUDY OF A BEAM ENERGY RECOVERY-SYSTEM FOR A NEGATIVE-ION-BASED NEUTRAL BEAM INJECTOR
    ARAKI, M
    OHARA, Y
    OKUMURA, Y
    FUSION TECHNOLOGY, 1990, 17 (04): : 555 - 565
  • [49] Assessment and modification of an ion source grid design in KSTAR neutral beam system
    Lee, Dong Won
    Shin, Kyu In
    Jin, Hyung Gon
    Choi, Bo Guen
    Kim, Tae-Seong
    Jeong, Seung Ho
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (02):
  • [50] Ion beam properties for ECR ion source injector systems
    Leitner, D.
    Winklehner, D.
    Strohmeier, M.
    JOURNAL OF INSTRUMENTATION, 2011, 6