Large-Scale Magnetic Microcalorimeter Arrays for the Lynx X-Ray Microcalorimeter

被引:1
|
作者
Devasia, Archana M. [1 ,2 ,3 ]
Bandler, Simon R. [1 ,2 ,3 ]
Ryu, Kevin [1 ,2 ,3 ]
Stevenson, Thomas R. [1 ,2 ,3 ]
Yoon, Wonsik [1 ,2 ,3 ]
机构
[1] NASA, Goddard Space Flight Ctr, Greenbelt, MD 20771 USA
[2] MIT, Lincoln Lab, Lexington, MA 02420 USA
[3] Sci Syst & Applicat Inc, Lanham, MD 20706 USA
关键词
Microcalorimeter; Superconducting wiring; Arrays; Hydra;
D O I
10.1007/s10909-022-02767-z
中图分类号
O59 [应用物理学];
学科分类号
摘要
The Lynx X-ray microcalorimeter (LXM) is an imaging spectrometer consisting of an array of greater than 100,000 pixels. Magnetic microcalorimeter (MMC) technology is a leading contender for detectors for the LXM. In this work, we detail the design of a full-size LXM MMC array fabricated using superconducting, multi-layer, buried wiring, with all pixels wired out on a full-size support wafer. We adopt a scheme that facilitates mixing and matching deep UV (DUV) and i-line (365 nm) steppers to stitch the high feature resolution detector array to the large field fanout wiring. To realize the main array of the microcalorimeter, we also employ a sandwich geometry. In this type of pixel, a superconducting ground plane placed above a paramagnetic sensor forces most of the magnetic flux to remain inside the sensor. This device aims to improve the coupling of the sensor to the pick-up coil, and thus enhance the energy resolution. Additionally, we introduce the integration of superconducting flux transformers to optimize the performance of the Ultra High Resolution Array. The wiring to each pixel terminates on bump bond pads, which allow future 2D microwave SQUID-based multiplexer chips to be indium bump bonded over the buried wiring. We present fabrication results and preliminary room temperature electrical measurements.
引用
收藏
页码:337 / 345
页数:9
相关论文
共 50 条
  • [21] Study of Multilayer X-ray Absorbers to Improve Detection Efficiency of TES X-ray Microcalorimeter Arrays
    Hayashi, T.
    Nagayoshi, K.
    Muramatsu, H.
    Yamasaki, N. Y.
    Mitsuda, K.
    Saito, M.
    Homma, T.
    Hara, T.
    Noda, H.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2016, 184 (1-2) : 257 - 262
  • [22] Micro-fabricated Magnetic Microcalorimeter Development for X-ray Astronomy
    Bandler, Simon R.
    Adams, Joseph S.
    Beyer, Joern
    Hsieh, Wen-Ting
    Rotzinger, Hannes
    Seidel, George M.
    Stevenson, Thomas
    HIGH ENERGY, OPTICAL, AND INFRARED DETECTORS FOR ASTRONOMY III, 2008, 7021
  • [23] Study of Multilayer X-ray Absorbers to Improve Detection Efficiency of TES X-ray Microcalorimeter Arrays
    T. Hayashi
    K. Nagayoshi
    H. Muramatsu
    N. Y. Yamasaki
    K. Mitsuda
    M. Saito
    T. Homma
    T. Hara
    H. Noda
    Journal of Low Temperature Physics, 2016, 184 : 257 - 262
  • [24] The X-ray Microcalorimeter Spectrometer onboard of Athena
    den Herder, J. W.
    Bagnali, D.
    Bandler, S.
    Barbera, M.
    Barcons, X.
    Barret, D.
    Bastia, P.
    Bisotti, M.
    Boyce, K.
    Cara, C.
    Ceballos, M.
    Corcione, L.
    Cobo, B.
    Colasanti, L.
    de Plaa, J.
    DiPirro, M.
    Doriese, W. B.
    Ezoe, Y.
    Fujimoto, R.
    Gatti, F.
    Gottardi, L.
    Guttridge, P.
    den Hartog, R.
    Hepburn, I.
    Kelley, R.
    Irwin, K.
    Ishisaki, Y.
    Kilbourne, C.
    de Korte, P. A. J.
    van der Kuur, J.
    Lotti, S.
    Macculi, C.
    Mitsuda, K.
    Mineo, T.
    Natalucci, L.
    Ohashi, T.
    Page, M.
    Paltani, S.
    Perinati, E.
    Piro, L.
    Pigot, C.
    Porter, F. S.
    Rauw, G.
    Ravera, L.
    Renotte, E.
    Sauvageot, J-L.
    Schmid, C.
    Sciortino, S.
    Shirron, P.
    Takei, Y.
    SPACE TELESCOPES AND INSTRUMENTATION 2012: ULTRAVIOLET TO GAMMA RAY, 2012, 8443
  • [25] Science metrics for a NASA large optic x-ray microcalorimeter mission
    Smith, Randall K.
    Bookbinder, Jay
    Garcia, Michael
    Hornschemeier, Ann
    Petre, Robert
    Ptak, Andrew
    SPACE TELESCOPES AND INSTRUMENTATION 2012: ULTRAVIOLET TO GAMMA RAY, 2012, 8443
  • [26] Microcalorimeter array development for X-ray astronomy
    Pigot, C
    Agnese, P
    Navick, XF
    Pelliciari, C
    Sauvageot, JL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 504 (1-3): : 339 - 342
  • [27] Time-division SQUID multiplexer for the readout of X-ray microcalorimeter arrays
    Doriese, WB
    Beall, JA
    Beyer, J
    Deiker, S
    Ferreira, L
    Hilton, GC
    Irwin, KD
    Martinis, JM
    Nam, SW
    Reintsema, CD
    Ullom, JN
    Vale, LR
    Xu, Y
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 520 (1-3): : 559 - 561
  • [28] NIST demonstrates breakthrough x-ray microcalorimeter
    不详
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 1996, 101 (03): : 404 - 404
  • [30] Status of X-ray microcalorimeter development at ISAS
    Fujimoto, R
    Mitsuda, K
    Iyomoto, N
    Audley, MD
    Miyazaki, T
    Oshima, T
    Yamazaki, M
    Futamoto, K
    Takei, Y
    Ishisaki, Y
    Kagei, T
    Hiroike, T
    Morita, U
    Ohashi, T
    Yamasaki, NY
    Kushino, A
    Kudo, H
    Sato, H
    Nakamura, T
    Goto, E
    Shoji, S
    Homma, T
    Osaka, T
    Kuroda, Y
    Onishi, M
    Goto, M
    Tanaka, K
    Morooka, T
    Nakayama, S
    Chinone, K
    LOW TEMPERATURE DETECTORS, 2002, 605 : 231 - 234