The equivalent circuit of an AT-cut quartz resonator and its application

被引:2
|
作者
Chen, PC [1 ]
Wu, L [1 ]
机构
[1] Natl Cheng Kung Univ, Dept Elect Engn, Tainan 70101, Taiwan
关键词
quartz resonator; resonator frequency; vacuum sensor; equivalent circuit;
D O I
10.1143/JJAP.39.2710
中图分类号
O59 [应用物理学];
学科分类号
摘要
The equivalent circuit of a AT-cut quartz resonator can be modified as a series circuit consisting of an inductance, a capacitance, a resistance in parallel with a capacitor, which are related to the dimensions, density, and elastic, dielectric, piezoelectric constants and electrode area of the quartz. In the other hand, a contacting fluid will cause an extra resistance and an inductance appeared, and an inductance appeared due to electrode mass loading effect. In this paper, two derivation methods of equivalent circuit models are used and compared to explain an AT-cut quartz resonator. Also a method to distinguish and calculate each components in equivalent circuit from gain-phase measurement is provided. Finally, the relation between air pressure and equivalent inductance and resistance are measured. The results shown that the lower air pressure the smaller equivalent inductance and resistance, when air pressure change from 1 atm to 1 g/cm(2), the equivalent resistance and the resonant frequency of resonator will change 5 Omega and 90 Hz, respectively.
引用
收藏
页码:2710 / 2713
页数:4
相关论文
共 50 条
  • [1] Equivalent circuit of an AT-cut quartz resonator and its application
    Chen, Ping-Cheng
    Wu, Long
    [J]. 2000, JJAP, Tokyo, Japan (39):
  • [2] Effect of electrode area on equivalent circuit of AT-cut quartz resonator
    Wu, Long
    Chen, Ping-Cheng
    Huang, Cheng-Liang
    Chu, Sheng-Yuan
    Song, Hong-Tie
    [J]. 2000, JJAP, Tokyo, Japan (39):
  • [3] Effect of electrode area on equivalent circuit of AT-cut quartz resonator
    Wu, L
    Chen, PC
    Huang, CL
    Chu, SY
    Song, HT
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2000, 39 (5A): : 2685 - 2689
  • [4] The Resonant Properties of AT-Cut Quartz Resonator and Its Application
    Chen, Ping-Cheng
    Pan, Chung-Long
    [J]. INFORMATION TECHNOLOGY APPLICATIONS IN INDUSTRY II, PTS 1-4, 2013, 411-414 : 1631 - +
  • [5] A Viscosity Sensor Using AT-Cut Quartz Resonator
    Chen, A. Ping-Cheng
    Pan, B. Chung-Long
    [J]. IEEE INTERNATIONAL SYMPOSIUM ON NEXT-GENERATION ELECTRONICS 2013 (ISNE 2013), 2013,
  • [6] Effects of Mismatched Electrodes on an AT-Cut Quartz Resonator
    He, Huijing
    Liu, Jinxi
    Yang, Jiashi
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (02) : 281 - 286
  • [7] THE OPTIMIZATION OF AT-CUT QUARTZ RESONATOR WITH CIRCULAR ELECTRODE
    Jin, Jun
    Zhang, Yan-ming
    Huang, Da-yong
    Huang, Xiang-miao
    Hu, Hong-ping
    [J]. PROCEEDINGS OF THE 2019 13TH SYMPOSIUM ON PIEZOELECTRICITY, ACOUSTIC WAVES AND DEVICE APPLICATIONS (SPAWDA), 2019,
  • [8] Frequency and equivalent circuit constant characteristics versus relative humidity for AT-cut quartz resonators
    Shimamoto, Y
    Kuroiwa, M
    Teramoto, N
    Wakamoto, S
    Imai, H
    Nakazawa, M
    [J]. PROCEEDINGS OF THE 2000 IEEE/EIA INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM & EXHIBITION, 2000, : 119 - 123
  • [9] Quadric analysis for AT-cut quartz resonator humidity sensors
    Nakazawa, M
    Kuroiwa, M
    Shimamoto, Y
    Iwahashi, H
    Wakamoto, S
    [J]. PROCEEDINGS OF THE 2000 IEEE/EIA INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM & EXHIBITION, 2000, : 124 - 127
  • [10] A Gaussian-shaped AT-cut quartz crystal resonator
    Abe, Takashi
    Kishi, Hiroki
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2011, 166 (02) : 173 - 176