Home sleep apnea testing: an accuracy study

被引:14
|
作者
Zancanella, Edilson [1 ,2 ]
do Prado, Lucila Fernandes [1 ]
de Carvalho, Luciane Bizari [1 ]
Machado Junior, Almiro J. [2 ]
Crespo, Agricio Nubiato [2 ]
do Prado, Gilmar Fernandes [1 ]
机构
[1] Univ Fed Sao Paulo, Neurol Dept, Neurosono Sleep Ctr, Sao Paulo, Brazil
[2] Univ Estadual Campinas, Dept Otorhinolaryngol Head & Neck Surg, UNICAMP, Campinas, SP, Brazil
关键词
Home sleep monitoring; Polysomnography; Type 2 portable polysomnography; Sleep apnea;
D O I
10.1007/s11325-021-02372-6
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Aim There are no studies comparing tests performed at home with those carried out in the laboratory, using the same device. The only studies that have been performed have compared the device used at home with the standard polygraph used in the laboratory. The purpose of this study was therefore to verify the accuracy of the home diagnosis of obstructive sleep apnea syndrome (OSAS) via unassisted type 2 portable polysomnography, compared with polysomnography using the same equipment in a sleep laboratory. Methods To avoid any possible order effect on the apnea-hypopnea index (AHI), we randomly created two groups of 20-total 40 patients, according to the test sequence. One of the groups had the first test at home and the second test in the laboratory (H-L); the other group had the first test in the laboratory and the second at home (L-H). The second test always took place on the night immediately following the first test. All polysomnographic monitoring was undertaken with the same equipment, an Embletta X100 system (Embla, Natus Inc., Middleton, USA). The Embletta X100 is a portable polygraph that records eleven polygraph signs: (1) electroencephalogram C4/A; (2) electroencephalogram O2/M1; (3) submental EMG; (4) electrooculogram of the right side; (5) nasal cannula (air flow); (6) respiratory effort against a plethysmographic chest strap; (7) respiratory effort against an abdominal plethysmographic belt; (8) heart rate; (9) saturation of oxyhemoglobin; (10) snoring; and (11) body position. Results There was no difference in sleep efficiency between the group monitored in the laboratory and the group tested at home (p = 0.30). There was no difference in total sleep time (p = 0.11) or sleep latency (p = 0.52), or in the latency in phases N2 and N3 between the monitoring in the laboratory and at home (N2 p = 0.24; N3 p = 0.09). Some differences occurred regarding the PSG that took place at home, with longer duration of wake after sleep onset (WASO) and longer latency for REM sleep, due to failure of the patient to start the monitoring by pressing the "events" button on the device. In the distribution of sleep phases, there was no difference between the group monitored in the laboratory and the group tested at home. Conclusion Results from home sleep monitoring correlate well with the laboratory "gold standard" and may be an option for diagnosing OSAS in selected patients.
引用
收藏
页码:117 / 123
页数:7
相关论文
共 50 条
  • [41] Measuring Loop Gain via Home Sleep Testing in Patients with Obstructive Sleep Apnea
    Orr, Jeremy E.
    Sands, Scott A.
    Edwards, Bradley A.
    Deyoung, Pamela N.
    Deacon, Naomi
    Jen, Rachel
    Li, Yanru
    Owens, Robert L.
    Malhotra, Atul
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2018, 197 (10) : 1353 - 1355
  • [42] VALIDATION OF A NOVEL WEARABLE HOME SLEEP TESTING DEVICE FOR ASSESSMENT OF OBSTRUCTIVE SLEEP APNEA
    Yeh, E.
    Wong, E.
    Strohl, K.
    Gu, W.
    Tsai, C.
    Leung, L.
    Yar, W.
    Chiang, A.
    [J]. SLEEP, 2020, 43 : A459 - A460
  • [43] Home Sleep Testing to Direct Upper Airway Stimulation Therapy Optimization for Sleep Apnea
    Steffen, Armin
    Koenig, Inke R.
    Baptista, Peter M.
    Abrams, Nils
    Jeschke, Stephanie
    Hasselbacher, Katrin
    [J]. LARYNGOSCOPE, 2021, 131 (04): : E1375 - E1379
  • [44] PRO: Sliding into Home: Portable Sleep Testing Is Effective for Diagnosis of Obstructive Sleep Apnea
    Kirsch, Douglas B.
    [J]. JOURNAL OF CLINICAL SLEEP MEDICINE, 2013, 9 (01): : 5 - 7
  • [45] Negative Home Sleep Testing in Patients with High Risk Obstructive Sleep Apnea Characteristics
    Stanchina, M. L.
    Prenda, S.
    Lincoln, J.
    Holt, M.
    Bunch, A.
    Donat, W. E.
    Corrao, W. M.
    Malhotra, A.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2019, 199
  • [46] HOME SLEEP APNEA TESTING: ARE WE DOING IT RIGHT IN PRIMARY CARE?
    Thomas, Akesh
    Obeidat, Nizar
    Musa, Rasheed
    Hoskere, Girendra
    [J]. CHEST, 2021, 160 (04) : 2438A - 2438A
  • [47] FACTORS ASSOCIATED WITH DISCORDANT INITIAL HOME SLEEP APNEA TESTING AND POLYSOMNOGRAPHY
    Escobar, Andres
    Reyes, Stephan
    Majid, Ruckshanda
    [J]. SLEEP, 2023, 46 : A209 - A209
  • [48] A New Wearable System for Home Sleep Apnea Testing, Screening, and Classification
    Manoni, Alessandro
    Loreti, Federico
    Radicioni, Valeria
    Pellegrino, Daniela
    Della Torre, Luigi
    Gumiero, Alessandro
    Halicki, Damian
    Palange, Paolo
    Irrera, Fernanda
    [J]. SENSORS, 2020, 20 (24) : 1 - 26
  • [49] Unattended Hospital and Home Sleep Apnea Testing Following Cerebrovascular Events
    Boulos, Mark I.
    Elias, Sara
    Wan, Anthony
    Im, James
    Frankul, Fadi
    Atalla, Mina
    Black, Sandra E.
    Basile, Vincenzo S.
    Sundaram, Arun
    Hopyan, Julia J.
    Boyle, Karl
    Gladstone, David J.
    Swartz, Richard H.
    Murray, Brian J.
    [J]. JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2017, 26 (01): : 143 - 149
  • [50] OUTCOMES OF HOME SLEEP APNEA TESTING STRATIFIED BY SPECIALIZATION OF THE REFERRING PHYSICIAN
    Al-Sharif, Hussam Z.
    Culpepper, David
    Stretch, Robert
    Aysola, Ravi
    Zeidler, Michelle
    [J]. SLEEP, 2019, 42