Home sleep apnea testing: an accuracy study

被引:14
|
作者
Zancanella, Edilson [1 ,2 ]
do Prado, Lucila Fernandes [1 ]
de Carvalho, Luciane Bizari [1 ]
Machado Junior, Almiro J. [2 ]
Crespo, Agricio Nubiato [2 ]
do Prado, Gilmar Fernandes [1 ]
机构
[1] Univ Fed Sao Paulo, Neurol Dept, Neurosono Sleep Ctr, Sao Paulo, Brazil
[2] Univ Estadual Campinas, Dept Otorhinolaryngol Head & Neck Surg, UNICAMP, Campinas, SP, Brazil
关键词
Home sleep monitoring; Polysomnography; Type 2 portable polysomnography; Sleep apnea;
D O I
10.1007/s11325-021-02372-6
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Aim There are no studies comparing tests performed at home with those carried out in the laboratory, using the same device. The only studies that have been performed have compared the device used at home with the standard polygraph used in the laboratory. The purpose of this study was therefore to verify the accuracy of the home diagnosis of obstructive sleep apnea syndrome (OSAS) via unassisted type 2 portable polysomnography, compared with polysomnography using the same equipment in a sleep laboratory. Methods To avoid any possible order effect on the apnea-hypopnea index (AHI), we randomly created two groups of 20-total 40 patients, according to the test sequence. One of the groups had the first test at home and the second test in the laboratory (H-L); the other group had the first test in the laboratory and the second at home (L-H). The second test always took place on the night immediately following the first test. All polysomnographic monitoring was undertaken with the same equipment, an Embletta X100 system (Embla, Natus Inc., Middleton, USA). The Embletta X100 is a portable polygraph that records eleven polygraph signs: (1) electroencephalogram C4/A; (2) electroencephalogram O2/M1; (3) submental EMG; (4) electrooculogram of the right side; (5) nasal cannula (air flow); (6) respiratory effort against a plethysmographic chest strap; (7) respiratory effort against an abdominal plethysmographic belt; (8) heart rate; (9) saturation of oxyhemoglobin; (10) snoring; and (11) body position. Results There was no difference in sleep efficiency between the group monitored in the laboratory and the group tested at home (p = 0.30). There was no difference in total sleep time (p = 0.11) or sleep latency (p = 0.52), or in the latency in phases N2 and N3 between the monitoring in the laboratory and at home (N2 p = 0.24; N3 p = 0.09). Some differences occurred regarding the PSG that took place at home, with longer duration of wake after sleep onset (WASO) and longer latency for REM sleep, due to failure of the patient to start the monitoring by pressing the "events" button on the device. In the distribution of sleep phases, there was no difference between the group monitored in the laboratory and the group tested at home. Conclusion Results from home sleep monitoring correlate well with the laboratory "gold standard" and may be an option for diagnosing OSAS in selected patients.
引用
收藏
页码:117 / 123
页数:7
相关论文
共 50 条
  • [1] Home sleep apnea testing: an accuracy study
    Edilson Zancanella
    Lucila Fernandes do Prado
    Luciane Bizari de Carvalho
    Almiro J. Machado Júnior
    Agrício Nubiato Crespo
    Gilmar Fernandes do Prado
    [J]. Sleep and Breathing, 2022, 26 : 117 - 123
  • [2] Improving Accuracy of Home Sleep Apnea Testing
    Claman, David
    Sunwoo, Bernie
    [J]. JOURNAL OF CLINICAL SLEEP MEDICINE, 2017, 13 (01): : 9 - 10
  • [3] Diagnostic Accuracy of Home Sleep Apnea Testing Based on Recording Duration
    Fynn, T. A.
    Alnemri, A.
    Grewal, R. G.
    Vasudevan, P.
    Doghramji, K.
    Tingting, Z.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2020, 201
  • [4] Home Sleep Apnea Testing for the Diagnosis of Obstructive Sleep Apnea
    Hoff, Scott
    Collop, Nancy
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2023, 329 (02): : 169 - 170
  • [5] DIAGNOSTIC ACCURACY OF HOME SLEEP STUDIES FOR SLEEP APNEA
    Grant, B.
    [J]. SLEEP, 2009, 32 : A232 - A233
  • [6] Underestimation of Sleep Apnea With Home Sleep Apnea Testing Compared to In-Laboratory Sleep Testing
    Setty, Arveity R.
    [J]. JOURNAL OF CLINICAL SLEEP MEDICINE, 2017, 13 (04): : 531 - 532
  • [7] Out of the Laboratory and into the Home: Home Testing for Sleep Apnea and Other Sleep Disorders
    Dredla, Brynn K.
    Castillo, Pablo R.
    [J]. JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2023, 40 (03) : 198 - 202
  • [8] Diagnostic accuracy of home sleep apnea testing using peripheral arterial tonometry for sleep apnea: A systematic review and meta-analysis
    Ichikawa, Masahiro
    Akiyama, Tomoaki
    Tsujimoto, Yasushi
    Anan, Keisuke
    Yamakawa, Tadashi
    Terauchi, Yasuo
    [J]. JOURNAL OF SLEEP RESEARCH, 2022, 31 (06)
  • [9] Impact of cardiorespiratory sleep staging for home sleep apnea testing
    Anderer, Peter
    Ross, Marco
    Cerny, Andreas
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2020, 56
  • [10] Sex differences in sleep apnea predictors and outcomes from home sleep apnea testing
    Cairns, Alyssa
    Poulos, Greg
    Bogan, Richard
    [J]. NATURE AND SCIENCE OF SLEEP, 2016, 8 : 197 - 205