Sensitive determination of oxybutynin and desethyloxybutynin in dog plasma by LC-ESI/MS/MS

被引:15
|
作者
Kim, H
Han, SB
机构
[1] SCL, Seoul Med Sci Inst, Dept Pharmacokinet, Yongsan Gu, Seoul 140809, South Korea
[2] BioCore Co Ltd, Dept Drug Dev Serv, Seoul 137130, South Korea
关键词
tandem mass spectrometry; liquid chromatography; multiple reaction monitoring; oxybutynin; desethyloxybutynin; diazepam;
D O I
10.1016/S0731-7085(02)00644-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and selective liquid chromatographic method coupled with tandem mass spectrometry (LC-MS/MS) was developed for the quantification of oxybutynin and desethyloxybutynin in dog plasma. Diazepam was used as internal standard, with plasma sample extracted using n-hexane and back-extracted using hydrochloric acid. A centrifuged lower layer (aqueous layer) was injected into a C-18 XTerra MS column (2.1 x 30 mm(2)) with 3.5 mum particle size. The analytical column lasted for at least 500 injections. The mobile phase was composed of 90% methanol, with flow rate at 200 mul/min. The mass spectrometer was operated in positive ion mode using electrospray ionization. Nitrogen was used as the nebulizer gas and argon was used as the collision gas. Using MS/MS with multiple reaction monitoring (NRM) mode, oxybutynin and desethyloxybutynin were detected without severe interferences from plasma matrix. Oxybutynin produced a protonated precursor ion ([M+H](+)) at m/z 358 and a corresponding product ion at m/z 142. Desethyloxybutynin produced a protonated precursor ion ([M+H](+)) at m/z 330 and a corresponding product ion at m/z 96. And internal standard (diazepam) produced a protonated precursor ion ([M+H](+)) at m/z 285 and a corresponding product ion at m/z 193. Detection of oxybutynin and desethyloxybutynin in dog plasma were accurate and precise, with detection limit at 0.1 ng/ml. This method has been successfully applied to a study of oxybutynin and desethyloxybutynin in dog plasma. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:341 / 349
页数:9
相关论文
共 50 条
  • [11] LC–ESI–MS for Rapid and Sensitive Determination of Aripiprazole in Human Plasma
    Xiao-cong Zuo
    Feng Wang
    Ping Xu
    Rong-hua Zhu
    Huan-de Li
    Chromatographia, 2006, 64 : 387 - 391
  • [12] Sensitive LC–ESI–MS Method for Determination of Tiopronin in Human Plasma
    L. Lai
    L. Ma
    X. J. Chen
    G. J. Wang
    J. P. Wang
    A. K. Davey
    Chromatographia, 2006, 64 : 655 - 659
  • [13] Sensitive determination of felodipine in human and dog plasma by use of liquid-liquid extraction and LC-ESI-MS-MS
    Kim, H
    Roh, H
    Yeom, SB
    Lee, HJ
    Han, SB
    CHROMATOGRAPHIA, 2003, 58 (3-4) : 235 - 240
  • [14] Sensitive LC-ESI/MS/MS assay for the quantification and pharmacokinetic study of roxithromycin in human serum
    Xu, Yu
    Li, Na
    Luo, Yanan
    Sun, Junjie
    Jiang, Bo
    Guo, Qingxiang
    JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 68 (08) : 743 - 747
  • [15] LC-ESI MS/MS quantification of atropine and six other antimuscarinic tropane alkaloids in plasma
    John, Harald
    Binder, Tobias
    Hoechstetter, Hans
    Thiermann, Horst
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (02) : 751 - 763
  • [16] LC-ESI MS/MS quantification of atropine and six other antimuscarinic tropane alkaloids in plasma
    Harald John
    Tobias Binder
    Hans Höchstetter
    Horst Thiermann
    Analytical and Bioanalytical Chemistry, 2010, 396 : 751 - 763
  • [17] Analysis of clenbuterol in bovine muscle and milk by LC-ESI/MS/MS
    Hong, Selyung
    Jeong, Jiyoon
    Park, Hyejin
    Lee, Soonho
    Lee, Jongok
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2008, 21 (06): : 535 - 542
  • [18] A Sensitive LC–ESI–MS Method for Pharmacokinetic Studies of Picroside II in Dog Plasma
    Qiao-Ling Yu
    Ying Zhao
    Xi-Jing Chen
    Zi-Dong Gao
    Wei-Chao Ren
    Hui He
    Jing Jing
    Yue Wang
    De-En Han
    Chromatographia, 2008, 67 : 1013 - 1016
  • [19] Sensitive LC-ESI-MS method for determination of tiopronin in human plasma
    Lai, L.
    Ma, L.
    Chen, X. J.
    Wang, G. J.
    Wang, J. P.
    Davey, A. K.
    CHROMATOGRAPHIA, 2006, 64 (11-12) : 655 - 659
  • [20] LC-ESI-MS for rapid and sensitive determination of aripiprazole in human plasma
    Zuo, Xiao-cong
    Wang, Feng
    Xu, Ping
    Zhu, Rong-hua
    Li, Huan-de
    CHROMATOGRAPHIA, 2006, 64 (7-8) : 387 - 391