A ratiometric near-infrared fluorescent probe based on a novel reactive cyanine platform for mitochondrial pH detection

被引:31
|
作者
Wan, Shulin [1 ]
Xia, Shuai [1 ]
Medford, Jerry [1 ]
Durocher, Emma [1 ]
Steenwinkel, Tessa E. [2 ]
Rule, Lexi [1 ]
Zhang, Yibin [1 ]
Luck, Rudy L. [1 ]
Werner, Thomas [2 ]
Liu, Haiying [1 ]
机构
[1] Michigan Technol Univ, Dept Chem, Houghton, MI 49931 USA
[2] Michigan Technol Univ, Dept Biol Sci, Houghton, MI 49931 USA
基金
美国国家卫生研究院;
关键词
SENSITIVE DETECTION; LIVE CELLS; ENERGY-TRANSFER; HEMICYANINE; DYES; CHEMISTRY; ACCEPTORS; EMISSION;
D O I
10.1039/d1tb00643f
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
A near-infrared reactive cyanine platform (probe A) was prepared by condensation of 9-chloro-1,2,3,4-tetrahydro-10-methyl-acridinium iodide with Fisher's aldehyde. A near-infrared fluorescent probe (probe B) was prepared by modifying a reactive chlorine atom of probe A with tert-butyl(2-aminoethyl)carbamate through a substitution reaction. The deprotection of the Boc group of probe B was achieved under an acidic condition, affording an amine-functionalized cyanine dye (probe C). A near-infrared ratiometric fluorescent probe (probe D) for mitochondrial pH detection was synthesized by conjugating a FRET coumarin donor to a FRET cyanine acceptor (probe C) through an amide bond connection. Probe A shows low fluorescence of 2% due to an electron-withdrawing chlorine atom, while probes B-D display high fluorescence quantum yields of 60%, 32%, and 35% in aqueous solutions containing 10% ethanol, respectively. Probes B-D show strong fluorescence with push-pull molecular structures in neutral and basic pH conditions. However, protonation of the probe's second amine at the 9-position under acidic condition disrupts the push-pull feature of the probes, resulting in fluorescence quenching of the new cyanine fluorophores. The probes can selectively stain mitochondria, while probe D was employed to detect pH changes in HeLa cells and Drosophila melanogaster first-instar larvae.
引用
收藏
页码:5150 / 5161
页数:12
相关论文
共 50 条
  • [41] Design and synthesis of a squaraine based near-infrared fluorescent probe for the ratiometric detection of Zn2+ ions
    Huang, Yangwei
    Lin, Qian
    Wu, Jiaming
    Fu, Nanyan
    DYES AND PIGMENTS, 2013, 99 (03) : 699 - 704
  • [42] Detection of Selenocysteine with a Ratiometric near-Infrared Fluorescent Probe in Cells and in Mice Thyroid Diseases Model
    Luo, Xianzhu
    Wang, Rui
    Lv, Chuanzhu
    Chen, Guang
    You, Jinmao
    Yu, Fabiao
    ANALYTICAL CHEMISTRY, 2020, 92 (01) : 1589 - 1597
  • [43] Design of a ratiometric near-infrared fluorescent probe with double excitation for hydrazine detection in vitro and in vivo
    Zhang, Tengteng
    Lai, Youbo
    Lin, Weiying
    SCIENCE OF THE TOTAL ENVIRONMENT, 2022, 837
  • [44] Real-time visualization the pH fluctuations of living cells with a ratiometric near-infrared fluorescent probe
    Ma, Jianlong
    Lu, Xiaofeng
    Hao, Mingyao
    Wang, Yumeng
    Guo, Yong
    Wang, Zhijun
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2024, 306
  • [45] Visible to Near-Infrared Emission Ratiometric Fluorescent Probe for the Detection of Vanin-1 In Vivo
    Qian, Jing
    Teng, Zhidong
    Wang, Jiemin
    Zhang, Liang
    Cao, Ting
    Zheng, Lei
    Cao, Yuping
    Qin, Wenwu
    Liu, Yun
    Guo, Huichen
    ACS SENSORS, 2020, 5 (09) : 2806 - 2813
  • [46] A quinoline-coumarin near-infrared ratiometric fluorescent probe for detection of sulfur dioxide derivatives
    Liu, Feng-Ting
    Li, Na
    Chen, Yong-Shun
    Yu, Hui-Ying
    Miao, Jun-Ying
    Zhao, Bao-Xiang
    ANALYTICA CHIMICA ACTA, 2022, 1211
  • [47] Monitoring the pH fluctuation of lysosome under cell stress using a near-infrared ratiometric fluorescent probe
    Gui, Lijuan
    Wang, Kaizhen
    Wang, Yuxin
    Yan, Jun
    Liu, Xian
    Guo, Jingxuan
    Liu, Ji
    Deng, Dawei
    Chen, Haiyan
    Yuan, Zhenwei
    CHINESE CHEMICAL LETTERS, 2023, 34 (03)
  • [48] A mitochondrial targeted dual ratiometric near-infrared fluorescent probe based on ICT effect for the detection of SO2 derivative and its bioimaging
    Xu, Kangshuo
    Tang, Na
    Liu, Furong
    Ai, Yin
    Ding, Haichang
    Fan, Congbin
    Liu, Gang
    Pu, Shouzhi
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2024, 317
  • [49] A highly sensitive near-infrared ratiometric fluorescent probe for imaging of mitochondrial hydrazine in cells and in mice models
    Song, Yaqun
    Chen, Guang
    Han, Xiaoyue
    You, Jinmao
    Yu, Fabiao
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 286 : 69 - 76
  • [50] Monitoring the pH fluctuation of lysosome under cell stress using a near-infrared ratiometric fluorescent probe
    Lijuan Gui
    Kaizhen Wang
    Yuxin Wang
    Jun Yan
    Xian Liu
    Jingxuan Guo
    Ji Liu
    Dawei Deng
    Haiyan Chen
    Zhenwei Yuan
    Chinese Chemical Letters, 2023, 34 (03) : 438 - 443