3D localization of vena contracta using Doppler ICE imaging in tricuspid valve interventions

被引:2
|
作者
Nisar, Hareem [1 ,2 ]
Fakim, Djalal [3 ]
Bainbridge, Daniel [4 ]
Chen, Elvis C. S. [1 ,2 ,3 ,5 ]
Peters, Terry [1 ,2 ,3 ,5 ]
机构
[1] Robarts Res Inst, 1151 Richmond St, London, ON N6A 5B7, Canada
[2] Western Univ, Sch Biomed Engn, 1151 Richmond St, London, ON N6A 3K7, Canada
[3] Western Univ, Schulic Sch Med & Dent, 1151 Richmond St, London, ON N6A 3K7, Canada
[4] London Hlth Sci Ctr, Dept Anesthesia & Perioperat Med, 339 Windermere Rd, London, ON N6A 5A5, Canada
[5] Western Univ, Dept Med Biophys, 1151 Richmond St, London, ON N6A 3K7, Canada
关键词
Tricuspid valve; Cardiac interventions; Intracardiac echocardiography (ICE); Image guided systems; Vena contracta localization; INTRACARDIAC ECHOCARDIOGRAPHY; REGURGITATION; REPAIR; ULTRASOUND; OUTCOMES;
D O I
10.1007/s11548-022-02660-w
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose Tricuspid valve (TV) interventions face the challenge of imaging the anatomy and tools because of the 'TEE-unfriendly' nature of the TV. In edge-to-edge TV repair, a core step is to position the clip perpendicular to the coaptation gap. In this study, we provide a semi-automated method to localize the VC from Doppler intracardiac echo (ICE) imaging in a tracked 3D space, thus providing a pre-mapped location of the coaptation gap to assist device positioning. Methods A magnetically tracked ICE probe with Doppler imaging capabilities is employed in this study for imaging three patient-specific TVs placed in a pulsatile heart phantom. For each of the valves, the ICE probe is positioned to image the maximum regurgitant flow for five cardiac cycles. An algorithm then extracts the regurgitation imaging and computes the exact location of the vena contracta on the image. Results Across the three pathological, patient-specific valves, the average distance error between the detected VC and the ground truth model is (1.22 +/- 2.00)mm. For each of the valves, one case represented the outlier where the algorithm misidentified the vena contracta to be near the annulus. In such cases, it is recommended to retake the five-second imaging data. Conclusion This study presented a method for ultrasound-based localization of vena contracta in 3D space. Mapping such anatomical landmarks has the potential to assist with device positioning and to simplify tricuspid valve interventions by providing more contextual information to the interventionalists, thus enhancing their spatial awareness. Additionally, ICE can be used to provide live US and Doppler imaging of the complex TV anatomy throughout the procedure.
引用
收藏
页码:1569 / 1577
页数:9
相关论文
共 50 条
  • [21] 3D VENA CONTRACTA AREA FOR THE QUANTIFICATION OF RESIDUAL MITRAL REGURGITATION AFTER MITRACLIP PROCEDURE
    Avenatti, Eleonora
    Reisman, Mark
    Barker, Colin
    Mackensen, G. Burkhard
    Little, Stephen
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 1254 - 1254
  • [22] 3D Vena Contracta Area to Quantify Severity of Mitral Regurgitation: A Practical New Tool?
    Maragiannis, Dimitrios
    Little, Stephen H.
    HELLENIC JOURNAL OF CARDIOLOGY, 2013, 54 (06) : 448 - 454
  • [23] Does orifice shape effect color Doppler jet shape, vena contracta and jet volume? An in vitro digital 3D reconstruction study
    PArk, YB
    Shiota, T
    Munt, BI
    Wanitkun, S
    Li, XN
    Otto, CM
    Sheehan, FH
    Martin, RW
    Sahn, DJ
    CIRCULATION, 1997, 96 (08) : 4205 - 4205
  • [24] Comprehensive Evaluation of Tricuspid Regurgitation Location and Severity Using Vena Contracta Analysis: A Color Doppler Three-Dimensional Transesophageal Echocardiographic Study
    Utsunomiya, Hiroto
    Harada, Yu
    Susawa, Hitoshi
    Takahari, Kosuke
    Ueda, Yusuke
    Izumi, Kanako
    Itakura, Kiho
    Ikenaga, Hiroki
    Hidaka, Takayuki
    Fukuda, Yukihiro
    Shiota, Takahiro
    Kihara, Yasuki
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2019, 32 (12) : 1526 - +
  • [25] Vena contracta area for severity grading in functional and degenerative mitral regurgitation: A study based on transesophageal 3D colour Doppler in 419 patients
    Goebel, B.
    Heck, R.
    Hamadanchi, A.
    Otto, S.
    Jung, C.
    Lauten, A.
    Figulla, H. R.
    Poerner, T. C.
    EUROPEAN HEART JOURNAL, 2015, 36 : 541 - 541
  • [26] Measurement of vena contracta areas for bileaflet mechanical valve prostheses using laser flow visualization: Comparison to the Doppler continuity equation
    Shandas, R
    Kwon, J
    Degroff, CG
    Gill, EA
    ValdesCruz, L
    CIRCULATION, 1997, 96 (08) : 2632 - 2632
  • [27] Understanding the Asymmetrical Vena Contracta Area The Difficult Relationship Between 2D and 3D Measurements
    Buck, Thomas
    Plicht, Bjoern
    Kahlert, Philipp
    Erbel, Raimund
    JACC-CARDIOVASCULAR IMAGING, 2013, 6 (06) : 744 - 744
  • [28] 3D IMAGING OF ICE SHEETS
    Paden, John
    Allen, Chris
    Gogineni, Prasad
    2010 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, 2010, : 2611 - 2613
  • [29] 3D heart models for planning of percutaneous tricuspid interventions
    Taramasso, Maurizio
    Phalla, Ou
    Spagnolo, Pietro
    Guidotti, Andrea
    Vicentini, Luca
    Scherman, Jacques
    Latib, Azeem
    Maisano, Francesco
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B53 - B53
  • [30] Dealiasing of mitral regurgitant color Doppler flow: A novel approach for direct flow quantification at the vena contracta based on real-time 3D color Doppler echocardiography
    Plicht, Bjoern
    Goldwasser, Ranny
    Kahlert, Philipp
    Buck, Thomas
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (09) : 103A - 103A