3D localization of vena contracta using Doppler ICE imaging in tricuspid valve interventions

被引:2
|
作者
Nisar, Hareem [1 ,2 ]
Fakim, Djalal [3 ]
Bainbridge, Daniel [4 ]
Chen, Elvis C. S. [1 ,2 ,3 ,5 ]
Peters, Terry [1 ,2 ,3 ,5 ]
机构
[1] Robarts Res Inst, 1151 Richmond St, London, ON N6A 5B7, Canada
[2] Western Univ, Sch Biomed Engn, 1151 Richmond St, London, ON N6A 3K7, Canada
[3] Western Univ, Schulic Sch Med & Dent, 1151 Richmond St, London, ON N6A 3K7, Canada
[4] London Hlth Sci Ctr, Dept Anesthesia & Perioperat Med, 339 Windermere Rd, London, ON N6A 5A5, Canada
[5] Western Univ, Dept Med Biophys, 1151 Richmond St, London, ON N6A 3K7, Canada
关键词
Tricuspid valve; Cardiac interventions; Intracardiac echocardiography (ICE); Image guided systems; Vena contracta localization; INTRACARDIAC ECHOCARDIOGRAPHY; REGURGITATION; REPAIR; ULTRASOUND; OUTCOMES;
D O I
10.1007/s11548-022-02660-w
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose Tricuspid valve (TV) interventions face the challenge of imaging the anatomy and tools because of the 'TEE-unfriendly' nature of the TV. In edge-to-edge TV repair, a core step is to position the clip perpendicular to the coaptation gap. In this study, we provide a semi-automated method to localize the VC from Doppler intracardiac echo (ICE) imaging in a tracked 3D space, thus providing a pre-mapped location of the coaptation gap to assist device positioning. Methods A magnetically tracked ICE probe with Doppler imaging capabilities is employed in this study for imaging three patient-specific TVs placed in a pulsatile heart phantom. For each of the valves, the ICE probe is positioned to image the maximum regurgitant flow for five cardiac cycles. An algorithm then extracts the regurgitation imaging and computes the exact location of the vena contracta on the image. Results Across the three pathological, patient-specific valves, the average distance error between the detected VC and the ground truth model is (1.22 +/- 2.00)mm. For each of the valves, one case represented the outlier where the algorithm misidentified the vena contracta to be near the annulus. In such cases, it is recommended to retake the five-second imaging data. Conclusion This study presented a method for ultrasound-based localization of vena contracta in 3D space. Mapping such anatomical landmarks has the potential to assist with device positioning and to simplify tricuspid valve interventions by providing more contextual information to the interventionalists, thus enhancing their spatial awareness. Additionally, ICE can be used to provide live US and Doppler imaging of the complex TV anatomy throughout the procedure.
引用
收藏
页码:1569 / 1577
页数:9
相关论文
共 50 条
  • [1] 3D localization of vena contracta using Doppler ICE imaging in tricuspid valve interventions
    Hareem Nisar
    Djalal Fakim
    Daniel Bainbridge
    Elvis C. S. Chen
    Terry Peters
    International Journal of Computer Assisted Radiology and Surgery, 2022, 17 : 1569 - 1577
  • [2] The Automatic Localization of the Vena Contracta using Intracardiac Echocardiography (ICE): A Feasibility Study
    Fakim, Djalal
    Nisar, Hareem
    Moore, John T.
    Peters, Terry M.
    Chen, Elvis C. S.
    MEDICAL IMAGING 2022: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2022, 12034
  • [3] The Vena Contracta Area Conquering Quantification With a 3D Cut?
    Little, Stephen H.
    JACC-CARDIOVASCULAR IMAGING, 2012, 5 (07) : 677 - 680
  • [4] Comparison of 2D vena contracta area with 3D planimetric mitral valve area in rheumatoid mitral valve disease
    G. Gok
    N. Sayar
    D. Oz
    H. B. Erer
    A. Ekmekci
    M. Eren
    The International Journal of Cardiovascular Imaging, 2020, 36 : 2115 - 2120
  • [5] Comparison of 2D vena contracta area with 3D planimetric mitral valve area in rheumatoid mitral valve disease
    Gok, G.
    Sayar, N.
    Oz, D.
    Erer, H. B.
    Ekmekci, A.
    Eren, M.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2020, 36 (11): : 2115 - 2120
  • [6] Diagnostic value of vena contracta area in the quantification of mitral regurgitation severity by color Doppler 3D echocardiography
    Elbenny, Ahmed
    Elsawy, Ezz Eldeen Abdelrahman
    Aldeftar, Mohamed Ismail Abdelkhalek
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2017, 19 (0F) : F7 - F7
  • [7] Diagnostic Value of Vena Contracta Area in the Quantification of Mitral Regurgitation Severity by Color Doppler 3D Echocardiography
    Zeng, Xin
    Levine, Robert A.
    Hua, Lanqi
    Morris, Eleanor L.
    Kang, Yuejian
    Flaherty, Mary
    Morgan, Nina V.
    Hung, Judy
    CIRCULATION-CARDIOVASCULAR IMAGING, 2011, 4 (05) : 506 - U91
  • [8] Correction to: Comparison of 2D vena contracta area with 3D planimetric mitral valve area in rheumatoid mitral valve disease
    G. Gok
    N. Sayar
    D. Oz
    H. B. Erer
    A. Ekmekci
    M. Eren
    The International Journal of Cardiovascular Imaging, 2020, 36 : 67 - 67
  • [9] A true bicuspid tricuspid valve: 3D imaging to better understanding the forgotten valve
    Nancy, N. Suarez-Lara
    Jose, A. Arias-Godinez
    Xochitl, A. Ortiz-Leon
    Edith, L. Posada-Martinez
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2025, 41 (02): : 391 - 392
  • [10] Quantitative assessment of chronic tricuspid regurgitation severity using vena contracta width by color flow imaging
    Ancheta-Puey, CMC
    Coching, RM
    Calleja, HB
    CIRCULATION, 2002, 106 (19) : 506 - 506