Oesophageal pH monitoring using the Bravo catheter-free radio capsule

被引:33
|
作者
Gillies, Richard S. [1 ]
Stratford, Jane M.
Booth, Michael I.
Dehn, Thomas C. B.
机构
[1] Royal Berkshire Hosp, Dept Upper Gastrointestinal Surg, Reading RG1 5AN, Berks, England
[2] Royal Berkshire Hosp, Dept Gastrointestinal Physiol, Reading RG1 5AN, Berks, England
关键词
Bravo; daily activities; discomfort; gastro-oesophageal reflux; disease diagnosis; pH monitoring;
D O I
10.1097/MEG.0b013e3280116eec
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Objectives: Oesophageal pH monitoring is the current standard for the diagnosis of gastro-oesophageal reflux disease. The Bravo capsule allows 48-h monitoring the need for a naso-oesophageal catheter. Our aim was assess the Bravo capsule in terms of patient discomfort and interference with daily activities, and to determine if 48-h Bravo pH studies facilitate the diagnosis of gastro-oesophageal reflux disease. Methods: Ambulatory pH studies were performed at two hospitals using either the Bravo capsule (n=100) or a conventional naso-oesophageal catheter (n=100). Participants were selected either for investigation of symptoms suggestive of gastro-oesophageal reflux disease, or to follow-up antireflux surgery. All participants completed questionnaires to assess discomfort and interference with daily activities. Results: Eighty-nine Bravo studies recorded at least 48 h of data, and 95 were diagnostic. Bravo participants reported significantly less discomfort during insertion (P < 0.0001) and monitoring (P < 0.0001), and less interference with daily activities (P < 0.0001), eating (P < 0.005), sleeping (P < 0.0001) and work (P < 0.0001). No significant difference was observed between day 1 and 2 median total time pH < 4 (4.0 and 4.3%, P=0.64), erect time PH < 4 (5.0 and 5.0%, P=0.56), supine time PH < 4 (0.5 and 0.5%, P=0.23), and Johnson-DeMeester scores (15.9 and 16.2, P=0.90). Ten Bravo participants (10%) were diagnosed with gastro-oesophageal reflux disease using day 2 data after a normal day 1. Conclusions: The Bravo capsule significantly reduces the patient discomfort and interference with normal daily activities during pH monitoring associated with a naso-oesophageal catheter. Moreover, 48-h Bravo studies offer an advantage over conventional 24-h studies in diagnosing gastro-oesophageal reflux disease.
引用
收藏
页码:57 / 63
页数:7
相关论文
共 50 条
  • [31] Chest Discomfort with Catheter-Free Ambulatory pH Monitoring can be Predicted by Response to PPIs
    McCann, Vinetta
    Nompleggi, Dominic
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2012, 107 : S27 - S27
  • [32] A novel, catheter-free method for measuring intragastric pH
    Carol Lovegrove
    Nature Clinical Practice Gastroenterology & Hepatology, 2005, 2 (11): : 500 - 501
  • [33] Bravo wireless versus catheter pH monitoring systems
    Fox, M
    GUT, 2006, 55 (03) : 434 - 435
  • [34] Radiographic appearance of a catheter-free wireless esophageal pH probe
    Lau, CT
    Gefter, WB
    Metz, DC
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (03) : S40 - S42
  • [35] Patient satisfaction with pH studies:: Bravo capsule V nasoesophageal catheter
    Lee, JTM
    Fox, M
    Mohsen, A
    Anggiansah, R
    Anggiansah, A
    Wong, T
    GUT, 2005, 54 : A78 - A78
  • [36] Utility of catheter-free ambulatory pH testing on PPI therapy
    Horine, Lydell C.
    Achem, Sami R.
    Bouras, Erncst P.
    Stark, Mark E.
    Ferguson, Dawn D.
    DeVault, Kenneth R.
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2007, 102 : S131 - S131
  • [37] Socioeconomic disparities in the use of catheter-free esophageal pH testing
    Sum, Eva
    Uppalapata, Seesha
    Kim, Joseph
    Richter, Joel
    Friedenberg, Frank
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2008, 103 : S1 - S1
  • [38] A Novel Placement Method of the Bravo Wireless pH Monitoring Capsule for Measuring Intragastric pH
    Jae Hyuck Chang
    Myung Gyu Choi
    Dong-Seok Yim
    Yu Kyung Cho
    Jae Myung Park
    In Seok Lee
    Sang Woo Kim
    In Sik Chung
    Digestive Diseases and Sciences, 2009, 54 : 578 - 585
  • [39] A Novel Placement Method of the Bravo Wireless pH Monitoring Capsule for Measuring Intragastric pH
    Chang, Jae Hyuck
    Choi, Myung Gyu
    Yim, Dong-Seok
    Cho, Yu Kyung
    Park, Jae Myung
    Lee, In Seok
    Kim, Sang Woo
    Chung, In Sik
    DIGESTIVE DISEASES AND SCIENCES, 2009, 54 (03) : 578 - 585
  • [40] Management of severe chest pain caused by a Bravo pH monitoring capsule
    Fischer, A.
    Baier, P. K.
    Utzolino, S.
    Hopt, U. T.
    Schrag, H. J.
    ENDOSCOPY, 2008, 40 : E55 - E56