Volumetric breast density measurement for personalized screening: accuracy, reproducibility, consistency, and agreement with visual assessment

被引:9
|
作者
Fieselmann, Andreas [1 ]
Fornvik, Daniel [2 ,3 ]
Fornvik, Hannie [2 ,3 ]
Lang, Kristina [2 ,3 ,4 ]
Sartor, Hanna [2 ,3 ]
Zackrisson, Sophia [2 ,3 ]
Kappler, Steffen [1 ]
Ritschl, Ludwig [1 ]
Mertelmeier, Thomas [1 ]
机构
[1] Siemens Healthcare GmbH, Forchheim, Germany
[2] Lund Univ, Dept Translat Med, Malmo, Sweden
[3] Skane Univ Hosp, Malmo, Sweden
[4] Swiss Fed Inst Technol, Inst Biomed Engn, Zurich, Switzerland
关键词
breast density; mammography; breast cancer; personalized screening; MAMMOGRAPHIC DENSITY; CANCER; RADIOLOGISTS; WOMEN;
D O I
10.1117/1.JMI.6.3.031406
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Assessment of breast density at the point of mammographic examination could lead to optimized breast cancer screening pathways. The onsite breast density information may offer guidance of when to recommend supplemental imaging for women in a screening program. A software application (Insight BD, Siemens Healthcare GmbH) for fast onsite quantification of volumetric breast density is evaluated. The accuracy of the method is assessed using breast tissue equivalent phantom experiments resulting in a mean absolute error of 3.84%. Reproducibility of measurement results is analyzed using 8427 exams in total, comparing for each exam (if available) the densities determined from left and right views, from cranio-caudal and medio-lateral oblique views, from full-field digital mammograms (FFDM) and digital breast tomosynthesis (DBT) data and from two subsequent exams of the same breast. Pearson correlation coefficients of 0.937, 0.926, 0.950, and 0.995 are obtained. Consistency of the results is demonstrated by evaluating the dependency of the breast density on women's age. Furthermore, the agreement between breast density categories computed by the software with those determined visually by 32 radiologists is shown by an overall percentage agreement of 69.5% for FFDM and by 64.6% for DBT data. These results demonstrate that the software delivers accurate, reproducible, and consistent measurements that agree well with the visual assessment of breast density by radiologists.
引用
收藏
页数:26
相关论文
共 50 条
  • [41] Accuracy and reproducibility of corneal topography data assessment based on different measurement principles
    Walkow, T
    Anders, N
    Hartmann, C
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S175 - S175
  • [42] Fully automated measurements of volumetric breast density adapted for BIRADS 5th edition: a comparison with visual assessment
    Youk, Ji Hyun
    Gweon, Hye Mi
    Son, Eun Ju
    Eun, Na Lae
    Kim, Jeong-Ah
    [J]. ACTA RADIOLOGICA, 2021, 62 (09) : 1148 - 1154
  • [43] Personalized breast cancer screening strategies: A systematic review and quality assessment
    Roman, Marta
    Sala, Maria
    Domingo, Laia
    Posso, Margarita
    Louro, Javier
    Castells, Xavier
    [J]. PLOS ONE, 2019, 14 (12):
  • [44] OBSERVER ACCURACY AND OBSERVER AGREEMENT IN THE MEASUREMENT OF VISUAL FIXATION WITH FIXED-TRIAL PROCEDURES
    HAAF, RA
    BREWSTER, M
    VICTOR, CMD
    SMITH, PH
    [J]. INFANT BEHAVIOR & DEVELOPMENT, 1989, 12 (02): : 211 - 220
  • [45] Validation of a new automated volumetric breast density measurement system as a marker of breast cancer risk
    K Pinker
    N Perry
    S Milner
    K Mokbel
    S Duffy
    [J]. Breast Cancer Research, 12
  • [46] Validation of a new automated volumetric breast density measurement system as a marker of breast cancer risk
    Pinker, K.
    Perry, N.
    Milner, S.
    Mokbel, K.
    Duffy, S.
    [J]. BREAST CANCER RESEARCH, 2010, 12
  • [47] An Interobserver Reproducibility Analysis of Ki67 Visual Assessment in Breast Cancer
    Shui, Ruohong
    Yu, Baohua
    Bi, Rui
    Yang, Fei
    Yang, Wentao
    [J]. PLOS ONE, 2015, 10 (05):
  • [48] Breast Density Legislation Impact on Breast Cancer Screening and Risk Assessment
    Kothari, Pranay
    Tseng, Joseph J.
    Chalfant, James S.
    Pittman, Sarah M.
    Hoyt, Anne C.
    Larsen, Linda
    Sheth, Pulin
    Yamashita, Mary
    Downey, John
    Ikeda, Debra M.
    [J]. JOURNAL OF BREAST IMAGING, 2022, 4 (04) : 371 - 377
  • [49] Accuracy of breast cancer detection with full-field digital mammography and integral computer-aided detection correlated with breast density as assessed by a new automated volumetric breast density measurement system
    K Pinker
    N Perry
    S Milner
    K Mokbel
    S Duffy
    [J]. Breast Cancer Research, 12
  • [50] Accuracy of breast cancer detection with full-field digital mammography and integral computer-aided detection correlated with breast density as assessed by a new automated volumetric breast density measurement system
    Pinker, K.
    Perry, N.
    Milner, S.
    Mokbel, K.
    Duffy, S.
    [J]. BREAST CANCER RESEARCH, 2010, 12