Volumetric breast density measurement for personalized screening: accuracy, reproducibility, consistency, and agreement with visual assessment

被引:9
|
作者
Fieselmann, Andreas [1 ]
Fornvik, Daniel [2 ,3 ]
Fornvik, Hannie [2 ,3 ]
Lang, Kristina [2 ,3 ,4 ]
Sartor, Hanna [2 ,3 ]
Zackrisson, Sophia [2 ,3 ]
Kappler, Steffen [1 ]
Ritschl, Ludwig [1 ]
Mertelmeier, Thomas [1 ]
机构
[1] Siemens Healthcare GmbH, Forchheim, Germany
[2] Lund Univ, Dept Translat Med, Malmo, Sweden
[3] Skane Univ Hosp, Malmo, Sweden
[4] Swiss Fed Inst Technol, Inst Biomed Engn, Zurich, Switzerland
关键词
breast density; mammography; breast cancer; personalized screening; MAMMOGRAPHIC DENSITY; CANCER; RADIOLOGISTS; WOMEN;
D O I
10.1117/1.JMI.6.3.031406
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Assessment of breast density at the point of mammographic examination could lead to optimized breast cancer screening pathways. The onsite breast density information may offer guidance of when to recommend supplemental imaging for women in a screening program. A software application (Insight BD, Siemens Healthcare GmbH) for fast onsite quantification of volumetric breast density is evaluated. The accuracy of the method is assessed using breast tissue equivalent phantom experiments resulting in a mean absolute error of 3.84%. Reproducibility of measurement results is analyzed using 8427 exams in total, comparing for each exam (if available) the densities determined from left and right views, from cranio-caudal and medio-lateral oblique views, from full-field digital mammograms (FFDM) and digital breast tomosynthesis (DBT) data and from two subsequent exams of the same breast. Pearson correlation coefficients of 0.937, 0.926, 0.950, and 0.995 are obtained. Consistency of the results is demonstrated by evaluating the dependency of the breast density on women's age. Furthermore, the agreement between breast density categories computed by the software with those determined visually by 32 radiologists is shown by an overall percentage agreement of 69.5% for FFDM and by 64.6% for DBT data. These results demonstrate that the software delivers accurate, reproducible, and consistent measurements that agree well with the visual assessment of breast density by radiologists.
引用
收藏
页数:26
相关论文
共 50 条
  • [1] Volumetric breast density measurement for personalized screening: accuracy, reproducibility, and agreement with visual assessment
    Fieselmann, Andreas
    Foernvik, Daniel
    Foernvik, Hannie
    Lang, Kristina
    Sartor, Hanna
    Zackrisson, Sophia
    Ritschl, Ludwig
    Mertelmeier, Thomas
    [J]. 14TH INTERNATIONAL WORKSHOP ON BREAST IMAGING (IWBI 2018), 2018, 10718
  • [2] Volumetric Breast Density Assessment: Reproducibility in Serial Examinations and Comparison with Visual Assessment
    Singh, J. M.
    Fallenberg, E. M.
    Diekmann, F.
    Renz, D. M.
    Witlandt, R.
    Bick, U.
    Engelken, F.
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2013, 185 (09): : 844 - 848
  • [3] Assessment of reproducibility of volumetric breast density measurement using dual energy digital breast tomosynthesis
    Huang, Hailiang
    Duan, Xiaoyu
    Zhao, Wei
    [J]. MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING, 2021, 11595
  • [4] Automated volumetric breast density estimation: A comparison with visual assessment
    Seo, J. M.
    Ko, E. S.
    Han, B. -K.
    Ko, E. Y.
    Shin, J. H.
    Hahn, S. Y.
    [J]. CLINICAL RADIOLOGY, 2013, 68 (07) : 690 - 695
  • [5] Reproducibility of visual assessment on mammographic density
    Gao, Jinnan
    Warren, Ruth
    Warren-Forward, Helen
    Forbes, John F.
    [J]. BREAST CANCER RESEARCH AND TREATMENT, 2008, 108 (01) : 121 - 127
  • [6] Reproducibility of visual assessment on mammographic density
    Jinnan Gao
    Ruth Warren
    Helen Warren-Forward
    John F. Forbes
    [J]. Breast Cancer Research and Treatment, 2008, 108 : 121 - 127
  • [7] Agreement of Mammographic Measures of Volumetric Breast Density to MRI
    Wang, Jeff
    Azziz, Ania
    Fan, Bo
    Malkov, Serghei
    Klifa, Catherine
    Newitt, David
    Yitta, Silaja
    Hylton, Nola
    Kerlikowske, Karla
    Shepherd, John A.
    [J]. PLOS ONE, 2013, 8 (12):
  • [8] Reproducibility of automated volumetric breast density assessment in short-term digital mammography reimaging
    Ko, Eun Sook
    Kim, Rock Bum
    Han, Boo-Kyung
    [J]. CLINICAL IMAGING, 2015, 39 (04) : 582 - 586
  • [9] Reproducibility of visual assessment of mammographic density.
    Gao, J. N.
    Warren, R.
    Forbes, J. F.
    Warren-Forward, H.
    D'Este, C.
    [J]. BREAST CANCER RESEARCH AND TREATMENT, 2006, 100 : S224 - S224
  • [10] Inter-observer agreement in visual analogue scale assessment of percentage breast density
    Sergeant, J. C.
    Wilson, M.
    Barr, N.
    Beetles, U.
    Boggis, C.
    Bundred, S.
    Bydder, M.
    Gadde, S.
    Hurley, E.
    Jain, A.
    Lim, Y.
    Lord, L.
    Reece, V.
    Evans, D. G.
    Howell, A.
    Astley, S. M.
    [J]. BREAST CANCER RESEARCH, 2013, 15