Effect of temperature variation on the visible and near infrared spectra of wine and the consequences on the partial least square calibrations developed to measure chemical composition

被引:88
|
作者
Cozzolino, D.
Liu, L.
Cynkar, W. U.
Dambergs, R. G.
Janik, L.
Colby, C. B.
Gishen, M.
机构
[1] Australian Wine Res Inst, Adelaide, SA 5064, Australia
[2] Cooperat Res Ctr Viticulture, Adelaide, SA 5064, Australia
[3] Univ Adelaide, Sch Chem Engn, Adelaide, SA 5005, Australia
关键词
near infrared spectra; temperature; wine; principal components; partial least squares; spectral changes; hydrogen bonding;
D O I
10.1016/j.aca.2007.01.079
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Many studies have reported the use of near infrared (NIR) spectroscopy to characterize wines or to predict wine chemical composition. However, little is known about the effect of variation in temperature on the NIR spectrum of wine and the subsequent effect on the performance of calibrations used to measure chemical composition. Several parameters influence the spectra of organic molecules in the NIR region, with temperature being one of the most important factors affecting the vibration intensity and frequency of molecular bonds. Wine is a complex mixture of chemical components (e.g. water, sugars, organic acids, and ethanol), and a simple ethanol and water model solution cannot be used to study the possible effects of temperature variations in the NIR spectrum of wine. Ten red and 10 white wines were scanned in triplicate at six different temperatures (25 degrees C, 30 degrees C, 35 degrees C, 40 degrees C, 45 degrees C and 50 degrees C in the visible (vis) and NIR regions (400-2500 nm) in a monochromator instrument in transmission mode (1 mm path length). Principal component analysis (PCA) and partial least squares (PLS) regression models were developed using full cross validation (leave-one-out). These models were used to interpret the spectra and to develop calibrations for alcohol, sugars (glucose + fructose) and pH at different temperatures. The results showed that differences in the spectra around 970 mn and 1400 nm, related to O-H bonding were observed for both varieties. Additionally an effect of temperature on the vis region of red wine spectra was observed. The standard error of cross validation (SECV) achieved for the PLS calibration models tended to inverse as the temperature increased. The practical implication of this study it is recommended that the temperature of scanning for wine analysis using a 1 mm path length cuvette should be between 30 degrees C and 35 degrees C. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:224 / 230
页数:7
相关论文
共 26 条
  • [21] Correlation analysis and partial least square modeling to quantify typical minerals with Chang'E-3 visible and near-infrared imaging spectrometer's ground validation data
    LIU Bin
    LIU Jianzhong
    ZHANG Guangliang
    LING Zongcheng
    ZHANG Jiang
    HE Zhiping
    YANG Benyong
    ZOU Yongliao
    Acta Geochimica, 2014, 33 (01) : 86 - 94
  • [22] Prediction of chemical characteristics of fibrous plant biomasses from their near infrared spectrum: comparing local versus partial least square models and cross-validation versus independent validations
    Godin, Bruno
    Agneessens, Richard
    Delcarte, Jerome
    Dardenne, Pierre
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2015, 23 (01) : 1 - 14
  • [23] The Effect of Time and Method of Storage on the Chemical Composition, Pepsin-Cellulase Digestibility, and Near-Infrared Spectra of Whole-Maize Forage
    Andueza, Donato
    Picard, Fabienne
    Barotin, Charlene
    Menanteau, Veronique
    Gervais, Corentin
    Maxin, Gaelle
    APPLIED SCIENCES-BASEL, 2019, 9 (24):
  • [24] Comparison of Fourier transform near infrared spectroscopy partial least square regression models for South African extra virgin olive oil using spectra collected on two spectrophotometers at different resolutions and path lengths
    Manley, Marena
    Eberle, Kerstin
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2006, 14 (02) : 111 - 126
  • [25] Qualitative analysis of trace Raman bands of non-resonant species in near-infrared excited pre-resonance Raman spectra of hemoglobin by partial least square regression-Raman excitation profile method
    Sato, H
    Wada, S
    Ozaki, Y
    Tashiro, H
    VIBRATIONAL SPECTROSCOPY, 2004, 34 (01) : 149 - 156
  • [26] Estimation of nitrogen, phosphorus, and potassium contents in the leaves of different plants using laboratory-based visible and near-infrared reflectance spectroscopy: comparison of partial least-square regression and support vector machine regression methods
    Zhai, Yanfang
    Cui, Lijuan
    Zhou, Xin
    Gao, Yin
    Fei, Teng
    Gao, Wenxiu
    INTERNATIONAL JOURNAL OF REMOTE SENSING, 2013, 34 (07) : 2502 - 2518