Effect of temperature variation on the visible and near infrared spectra of wine and the consequences on the partial least square calibrations developed to measure chemical composition

被引:88
|
作者
Cozzolino, D.
Liu, L.
Cynkar, W. U.
Dambergs, R. G.
Janik, L.
Colby, C. B.
Gishen, M.
机构
[1] Australian Wine Res Inst, Adelaide, SA 5064, Australia
[2] Cooperat Res Ctr Viticulture, Adelaide, SA 5064, Australia
[3] Univ Adelaide, Sch Chem Engn, Adelaide, SA 5005, Australia
关键词
near infrared spectra; temperature; wine; principal components; partial least squares; spectral changes; hydrogen bonding;
D O I
10.1016/j.aca.2007.01.079
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Many studies have reported the use of near infrared (NIR) spectroscopy to characterize wines or to predict wine chemical composition. However, little is known about the effect of variation in temperature on the NIR spectrum of wine and the subsequent effect on the performance of calibrations used to measure chemical composition. Several parameters influence the spectra of organic molecules in the NIR region, with temperature being one of the most important factors affecting the vibration intensity and frequency of molecular bonds. Wine is a complex mixture of chemical components (e.g. water, sugars, organic acids, and ethanol), and a simple ethanol and water model solution cannot be used to study the possible effects of temperature variations in the NIR spectrum of wine. Ten red and 10 white wines were scanned in triplicate at six different temperatures (25 degrees C, 30 degrees C, 35 degrees C, 40 degrees C, 45 degrees C and 50 degrees C in the visible (vis) and NIR regions (400-2500 nm) in a monochromator instrument in transmission mode (1 mm path length). Principal component analysis (PCA) and partial least squares (PLS) regression models were developed using full cross validation (leave-one-out). These models were used to interpret the spectra and to develop calibrations for alcohol, sugars (glucose + fructose) and pH at different temperatures. The results showed that differences in the spectra around 970 mn and 1400 nm, related to O-H bonding were observed for both varieties. Additionally an effect of temperature on the vis region of red wine spectra was observed. The standard error of cross validation (SECV) achieved for the PLS calibration models tended to inverse as the temperature increased. The practical implication of this study it is recommended that the temperature of scanning for wine analysis using a 1 mm path length cuvette should be between 30 degrees C and 35 degrees C. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:224 / 230
页数:7
相关论文
共 26 条
  • [1] Partial least square analysis of lysozyme near-infrared spectra
    Hu, SYB
    Lillquist, A
    Arnold, MA
    Wiencek, JM
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2000, 87 (03) : 153 - 163
  • [2] Partial least square analysis of lysozyme near-infrared spectra
    Shih-Yao B. Hu
    Amy Lillquist
    Mark A. Arnold
    John M. Wiencek
    Applied Biochemistry and Biotechnology, 2000, 87 : 153 - 163
  • [3] Using consensus interval partial least square in near infrared spectra analysis
    Ji, Guoli
    Huang, Guangzao
    Yang, Zijiang
    Wu, Xiaohui
    Chen, Xiaojing
    Yuan, Mingshun
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2015, 144 : 56 - 62
  • [4] Determination of Glucose Concentration from Near-Infrared Spectra Using Locally Weighted Partial Least Square Regression
    Malik, Bilal
    Benaissa, Mohammed
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 6169 - 6171
  • [5] Effect of freezing and grinding method on near-infrared reflectance (NIR) spectra variation and chemical composition of fresh silage
    Alomar, D
    Montero, R
    Fuchslocher, R
    ANIMAL FEED SCIENCE AND TECHNOLOGY, 1999, 78 (1-2) : 57 - 63
  • [6] Effect of water and physical state on near- and mid-infrared partial least squares calibrations for multicomponent carbohydrate mixtures
    Reeves, JB
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2004, 12 (04) : 241 - 249
  • [7] Correlation of color components of red wines using ultraviolet, visible, and infrared spectra and wine analyses and the method of partial least squares.
    Versari, A
    Thorngate, J
    Boulton, RB
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2003, 225 : U71 - U71
  • [8] The Effect of Path Length on the Measurement Accuracies of Wine Chemical Parameters by UV, Visible, and Near-Infrared Spectroscopy
    Molla, Nevse
    Bakardzhiyski, Ivan
    Manolova, Yana
    Bambalov, Valentin
    Cozzolino, Daniel
    Antonov, Liudmil
    FOOD ANALYTICAL METHODS, 2017, 10 (05) : 1156 - 1163
  • [9] The Effect of Path Length on the Measurement Accuracies of Wine Chemical Parameters by UV, Visible, and Near-Infrared Spectroscopy
    Nevse Molla
    Ivan Bakardzhiyski
    Yana Manolova
    Valentin Bambalov
    Daniel Cozzolino
    Liudmil Antonov
    Food Analytical Methods, 2017, 10 : 1156 - 1163
  • [10] Combining Partial Least Squares and the Gradient-Boosting Method for Soil Property Retrieval Using Visible Near-Infrared Shortwave Infrared Spectra
    Liu, Lanfa
    Ji, Min
    Buchroithner, Manfred
    REMOTE SENSING, 2017, 9 (12)