Effect of Plasma Sterilization on the Hemostatic Efficacy of a Chitosan Hemostatic Agent in a Rat Model

被引:10
|
作者
Crofton, Andrew [1 ,2 ]
Chrisler, John [3 ]
Hudson, Samuel [4 ]
Inceoglu, Serkan [5 ]
Petersen, Floyd [2 ]
Kirsch, Wolff [2 ,6 ]
机构
[1] Loma Linda Univ, Sch Med, Dept Anat, Loma Linda, CA USA
[2] Loma Linda Univ, Sch Med, Neurosurg Ctr Res Training & Educ, Loma Linda, CA USA
[3] Loma Linda Univ, Sch Med, Anim Care Facil, Loma Linda, CA USA
[4] N Carolina State Univ, Coll Text, Raleigh, NC 27695 USA
[5] Loma Linda Univ, Sch Med, Dept Orthoped Surg, Loma Linda, CA USA
[6] Loma Linda Univ, Sch Med, Div Biochem, Loma Linda, CA USA
基金
美国国家卫生研究院;
关键词
Chitosan; Hemostasis; Hemostatic agents; Non-thermal nitrogen plasma; Plasma sterilization; Rat model; LAPAROSCOPIC PARTIAL NEPHRECTOMY; N-ACETYL GLUCOSAMINE; LINGUAL HEMOSTASIS; HEMORRHAGE; INJURY; RABBITS; BIODEGRADATION; CYTOTOXICITY; INACTIVATION; DRESSINGS;
D O I
10.1007/s12325-016-0289-6
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The United States military has had success with chitosan (CS)-based hemostatic agents to control trauma-induced hemorrhages. Despite the positive reviews, additional physical forms of CS may enhance its hemostatic efficacy. Additionally, standard sterilization techniques may negatively affect the hemostatic efficacy of CS. We studied the effects of a CS-based hemostatic pad, the Clo-Sur P.A.D.(TM) (Scion Cardio-Vascular, Inc.), on severe femoral vessel bleeding in a rat model. The effects of different sterilization techniques on the bioadhesivity, surface atomic concentrations, and hemostatic efficacy of the P.A.D. were also evaluated. Hemostatic efficacy, bioadhesivity, and surface atomic concentrations of the P.A.D. were evaluated in its unsterilized form, after sterilization with standard e-beam treatment, and after sterilization with one of three types of non-thermal nitrogen plasma: nitrogen gas, air, or nitrous oxide plasma. After standardized puncture of the femoral artery or transection of the femoral vessels, rats were treated with either a CS P.A.D. or gauze pad. The Clo-Sur P.A.D., regardless of sterilization technique, stopped arterial and mixed arterial/venous bleeding in all cases in < 90 s with the time to hemostasis (TTH) significantly less for all P.A.D. treatment groups (P < 0.001; n = 4-5/group) compared to gauze-treated controls (n = 3). E-beam sterilized P.A.D.s consistently showed non-significant trends toward increased TTH and worse hemostasis scores compared to unsterilized and plasma sterilized P.A.D.s. Treating e-beam sterilized P.A.D.s with N-2 plasma reverted the hemostatic efficacy to levels equivalent to native, unsterilized PADs. A CS-based hemostatic pad successfully controlled severe bleeding in a rat model with combined e-beam and plasma sterilized P.A.D.s showing the most promising results. Further studies are warranted.
引用
收藏
页码:268 / 281
页数:14
相关论文
共 50 条
  • [41] A NEW ENDOSCOPIC MICROWAVE HEMOSTATIC DEVICE: AN EXPERIMENTAL STUDY OF SAFETY AND HEMOSTATIC EFFICACY IN A PORCINE MODEL
    Balzarini, M.
    Grossini, E.
    Molinari, C.
    Uberti, F.
    Valente, G.
    Vacca, G.
    Del Piano, M.
    Orsello, M.
    Carmagnola, S.
    Anderloni, A.
    Ballare, M.
    Cipolletta, L.
    Ficano, L.
    DIGESTIVE AND LIVER DISEASE, 2011, 43 : S228 - S228
  • [42] Improvement of Biological Properties of Natural Hemostatic Agent by Plasma Technology
    Wattanutchariya, Wassanai
    Boonyawan, Dheerawan
    Jaifu, Jureeporn
    2018 5TH INTERNATIONAL CONFERENCE ON MECHANICAL, MATERIALS AND MANUFACTURING (ICMMM 2018), 2018, 249
  • [43] EFFECT OF GELATIN PLASMA SUBSTITUTES ON HEMOSTATIC MECHANISM
    HEENE, DL
    LASCH, HG
    BIBLIOTHECA HAEMATOLOGICA, 1969, (33): : 428 - &
  • [44] Fresh frozen plasma: the most commonly prescribed hemostatic agent
    Puetz, J.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2013, 11 (10) : 1794 - 1799
  • [45] The Effect of Algan Hemostatic Agent (AHA) on Wound Healing
    Aksoy, Halil
    Sener, Azize
    Akakin, Dilek
    Sen, Ali
    Ozakpinar, Ozlem Bingol
    Ozcan, Sinemcan
    Simsek, Ahmet Kaan
    Sekerler, Turgut
    Guzel, Sevket Ergun
    Midi, Ahmet
    CLINICAL AND EXPERIMENTAL HEALTH SCIENCES, 2020, 10 (03): : 279 - 284
  • [46] HEMOPHILIC DOG-MODEL FOR EVALUATING HEMOSTATIC EFFICACY OF PLASMA-PROTEIN FRACTIONS
    KINGDON, HS
    HASSELL, TM
    THROMBOSIS AND HAEMOSTASIS, 1981, 46 (01) : 217 - 217
  • [47] Hemostatic Efficacy of Biological Self-Assembling Peptide Nanofibers in a Rat Kidney Model
    Song, Hong
    Zhang, Lanlan
    Zhao, Xiaojun
    MACROMOLECULAR BIOSCIENCE, 2010, 10 (01) : 33 - 39
  • [48] Comparison of the efficacy and histopathological effects of three hemostatic agents in a partial nephrectomy rat model
    Yucel, Mehmet Ozgur
    Polat, Haci
    Bagcioglu, Murat
    Karakan, Tolga
    Benlioglu, Can
    Cift, Ali
    Gok, Alper
    Astarci, Hesna Muzeyyen
    Akgul, Turgay
    Germiyanoglu, Cankon
    INTERNATIONAL UROLOGY AND NEPHROLOGY, 2016, 48 (01) : 65 - 71
  • [49] Comparison of the efficacy and histopathological effects of three hemostatic agents in a partial nephrectomy rat model
    Mehmet Ozgur Yucel
    Haci Polat
    Murat Bagcioglu
    Tolga Karakan
    Can Benlioglu
    Ali Cift
    Alper Gok
    Hesna Muzeyyen Astarci
    Turgay Akgul
    Cankon Germiyanoglu
    International Urology and Nephrology, 2016, 48 : 65 - 71
  • [50] Strong adhesive hemostatic agent based on catechol-chitosan and hyaluronic acid
    HaeIn, Jeong
    Won-Moon, Song
    Kyoung-Ha, So
    Suk-Yeon, Hwang Nathaniel
    TISSUE ENGINEERING PART A, 2022, 28 : 746 - 746