Effect of Plasma Sterilization on the Hemostatic Efficacy of a Chitosan Hemostatic Agent in a Rat Model

被引:10
|
作者
Crofton, Andrew [1 ,2 ]
Chrisler, John [3 ]
Hudson, Samuel [4 ]
Inceoglu, Serkan [5 ]
Petersen, Floyd [2 ]
Kirsch, Wolff [2 ,6 ]
机构
[1] Loma Linda Univ, Sch Med, Dept Anat, Loma Linda, CA USA
[2] Loma Linda Univ, Sch Med, Neurosurg Ctr Res Training & Educ, Loma Linda, CA USA
[3] Loma Linda Univ, Sch Med, Anim Care Facil, Loma Linda, CA USA
[4] N Carolina State Univ, Coll Text, Raleigh, NC 27695 USA
[5] Loma Linda Univ, Sch Med, Dept Orthoped Surg, Loma Linda, CA USA
[6] Loma Linda Univ, Sch Med, Div Biochem, Loma Linda, CA USA
基金
美国国家卫生研究院;
关键词
Chitosan; Hemostasis; Hemostatic agents; Non-thermal nitrogen plasma; Plasma sterilization; Rat model; LAPAROSCOPIC PARTIAL NEPHRECTOMY; N-ACETYL GLUCOSAMINE; LINGUAL HEMOSTASIS; HEMORRHAGE; INJURY; RABBITS; BIODEGRADATION; CYTOTOXICITY; INACTIVATION; DRESSINGS;
D O I
10.1007/s12325-016-0289-6
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The United States military has had success with chitosan (CS)-based hemostatic agents to control trauma-induced hemorrhages. Despite the positive reviews, additional physical forms of CS may enhance its hemostatic efficacy. Additionally, standard sterilization techniques may negatively affect the hemostatic efficacy of CS. We studied the effects of a CS-based hemostatic pad, the Clo-Sur P.A.D.(TM) (Scion Cardio-Vascular, Inc.), on severe femoral vessel bleeding in a rat model. The effects of different sterilization techniques on the bioadhesivity, surface atomic concentrations, and hemostatic efficacy of the P.A.D. were also evaluated. Hemostatic efficacy, bioadhesivity, and surface atomic concentrations of the P.A.D. were evaluated in its unsterilized form, after sterilization with standard e-beam treatment, and after sterilization with one of three types of non-thermal nitrogen plasma: nitrogen gas, air, or nitrous oxide plasma. After standardized puncture of the femoral artery or transection of the femoral vessels, rats were treated with either a CS P.A.D. or gauze pad. The Clo-Sur P.A.D., regardless of sterilization technique, stopped arterial and mixed arterial/venous bleeding in all cases in < 90 s with the time to hemostasis (TTH) significantly less for all P.A.D. treatment groups (P < 0.001; n = 4-5/group) compared to gauze-treated controls (n = 3). E-beam sterilized P.A.D.s consistently showed non-significant trends toward increased TTH and worse hemostasis scores compared to unsterilized and plasma sterilized P.A.D.s. Treating e-beam sterilized P.A.D.s with N-2 plasma reverted the hemostatic efficacy to levels equivalent to native, unsterilized PADs. A CS-based hemostatic pad successfully controlled severe bleeding in a rat model with combined e-beam and plasma sterilized P.A.D.s showing the most promising results. Further studies are warranted.
引用
收藏
页码:268 / 281
页数:14
相关论文
共 50 条
  • [1] Effect of Plasma Sterilization on the Hemostatic Efficacy of a Chitosan Hemostatic Agent in a Rat Model
    Andrew Crofton
    John Chrisler
    Samuel Hudson
    Serkan Inceoglu
    Floyd Petersen
    Wolff Kirsch
    Advances in Therapy, 2016, 33 : 268 - 281
  • [2] The efficacy of a hemostatic agent in anticoagulant drug-induced rat bleeding model
    Sonmez, Ertan
    Cavus, Umut Yucel
    Civelek, Cemil
    Dur, Ali
    Karayel, Eda
    Gulen, Bedia
    Uysal, Omer
    Ipek, Gokturk
    ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2014, 20 (02): : 79 - 85
  • [3] The Effect of a Hemostatic Agent (FastAct) to Wound and Tissue Repair in a Rat Model
    Okcu, Kemal Murat
    Dogan, Necdet
    Sencimen, Metin
    Korkmaz, Cem
    Altug, Hasan Ayberk
    Ide, Tayfun
    Akyol, Mesut
    TRAKYA UNIVERSITESI TIP FAKULTESI DERGISI, 2010, 27 (03): : 221 - 226
  • [4] A glimpse on the function of chitosan as a dental hemostatic agent
    Lestari, Widya
    Yusry, Wan Nur Aisyah Wan
    Haris, Muhammad Salahuddin
    Jaswir, Irwandi
    Idrus, Erik
    JAPANESE DENTAL SCIENCE REVIEW, 2020, 56 (01) : 147 - 154
  • [5] Invivo Hemostatic Effect of Ankaferd Blood Stopper in Rat Major Renal Trauma Model: Controlled Trial of Novel Hemostatic Agent
    Germiyanoglu, Cankon
    Huri, Emre
    Akgul, Turgay
    Ayyildiz, Ali
    Ustun, Huseyin
    UHOD-ULUSLARARASI HEMATOLOJI-ONKOLOJI DERGISI, 2010, 20 (04): : 206 - 211
  • [6] Hemostatic efficacy and safety of TachoComb in surgery - Ready to use and rapid hemostatic agent
    Agus, GB
    Bono, AV
    Mira, E
    Olivero, S
    Peilowich, A
    Homdrum, E
    Benelli, C
    INTERNATIONAL SURGERY, 1996, 81 (03) : 316 - 319
  • [7] Efficacy of New Polylactic Acid Nonwoven Fabric as a Hemostatic Agent in a Rat Liver Resection Model
    Wakabayashi, Taiga
    Yagi, Hiroshi
    Tajima, Kazuki
    Kuroda, Kohei
    Shinoda, Masahiro
    Kitago, Minoru
    Abe, Yuta
    Oshima, Go
    Hirukawa, Kazuya
    Itano, Osamu
    Kitagawa, Yuko
    SURGICAL INNOVATION, 2019, 26 (03) : 312 - 320
  • [8] Efficacy of new topical hemostatic agent aluferrum in a rat traumatic - Traumatic liver bleeding model
    Kremenevskiy, I
    Melnova, I
    Cheholskiy, A
    Gapanovich, V
    SHOCK, 2004, 21 : 16 - 16
  • [9] NEW HEMOSTATIC AGENT - HEMOSTATIC EFFECT OF COLLAGEN-PROTAMINE SPONGE
    KODAIRA, K
    MIYATA, T
    FURUSE, M
    NOISHIKI, Y
    ARTIFICIAL ORGANS, 1988, 12 (05) : 452 - 453
  • [10] Hemostatic Efficacy of Nanofibrous Matrix in Rat Liver Injury Model
    Jaiswal, Amit K.
    Chhabra, Hemlata
    Narwane, Sandipan
    Rege, Nirmala
    Bellare, Jayesh R.
    SURGICAL INNOVATION, 2017, 24 (01) : 23 - 28