Feasibility of Non-invasive Blood Pressure Estimation Based on Pulse Arrival Time: a MIMIC Database Study

被引:0
|
作者
Escobar, Braiam [1 ,2 ]
Torres, Robinson [1 ,2 ]
机构
[1] Escuela Ingn Antioquia, Envigado, Colombia
[2] Univ CES, Medellin, Colombia
关键词
TRANSIT-TIME; CALIBRATION;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of the present study was to evaluate the feasibility of blood pressure (BP) estimation by means of pulse arrival time (PAT) from data records of ICU patients available at the MIMIC public database. Datasets consisting of ECG, PPG and arterial BP waveforms from 8 subjects were used for the analysis and the relationship of PAT with systolic, diastolic and mean blood pressure was assessed through a linear regression fit. The analysis was carried out on datasets of short (20 min) and long (60 min) duration in order to evaluate the temporal changes on the linear relationship. The results showed high correlation between BP and PAT for both the short-term and the long-term analyses. The mean absolute error found between the true and estimated systolic BP values was close to 5mmHg; however, the error noticeably increased on the long-term dataset for all subjects.
引用
收藏
页码:1113 / 1116
页数:4
相关论文
共 50 条
  • [1] Optimizing Non-Invasive Blood Pressure Estimation Using Pulse Transit Time
    Jeong, In Cheol
    Finkelstein, Joseph
    MEDINFO 2013: PROCEEDINGS OF THE 14TH WORLD CONGRESS ON MEDICAL AND HEALTH INFORMATICS, PTS 1 AND 2, 2013, 192 : 1198 - 1198
  • [2] Comparison of simultaneous invasive and non-invasive measurements of blood pressure based upon MIMIC II database
    Liu B.
    Qiu P.
    Chen H.
    Li Q.
    Artery Research, 2014, 8 (4) : 209 - 213
  • [3] A novel method for non-invasive blood pressure estimation based on continuous pulse transit time: An observational study
    Shin, Hangsik
    PSYCHOPHYSIOLOGY, 2023, 60 (02)
  • [4] Microvascular Circulation And Pulse Arrival Time Variability: Implications For Non-invasive Blood Pressure Devices
    Anderson, Cody
    Allen, Michael
    Benitez, Andres
    Jones, Matt
    Jin, Dong Gun
    Weimer, Kollyn
    Erol, Muhammet Enes
    Layec, Gwenael
    Park, Song-Young
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2024, 56 (10) : 48 - 48
  • [5] Feasibility study for the non-invasive blood pressure estimation based on ppg morphology: normotensive subject study
    Shin, Hangsik
    Min, Se Dong
    BIOMEDICAL ENGINEERING ONLINE, 2017, 16
  • [6] Feasibility study for the non-invasive blood pressure estimation based on ppg morphology: normotensive subject study
    Hangsik Shin
    Se Dong Min
    BioMedical Engineering OnLine, 16
  • [7] Introduction of Boosting Algorithms in Continuous Non-Invasive Cuff-less Blood Pressure Estimation using Pulse Arrival Time
    Ghosh, Aayushman
    Chatterjee, Tamaghno
    Sarkar, Sayan
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 5429 - 5432
  • [8] How Effective Is Pulse Arrival Time for Evaluating Blood Pressure? Challenges and Recommendations from a Study Using the MIMIC Database
    Liang, Yongbo
    Abbott, Derek
    Howard, Newton
    Lim, Kenneth
    Ward, Rabab
    Elgendi, Mohamed
    JOURNAL OF CLINICAL MEDICINE, 2019, 8 (03):
  • [9] Evaluation of blood pressure estimation models based on pulse arrival time
    Bote, Jose M.
    Recas, Joaquin
    Hermida, Roman
    COMPUTERS & ELECTRICAL ENGINEERING, 2020, 84
  • [10] Correction Factor Estimation for a Parametric Model between Pulse Transit Time and Systolic Blood Pressure, for Non-Invasive Blood Pressure Estimation
    De Alwis, W. U. C.
    Rajapaksha, R. N. S.
    Ranaweera, N. N. S.
    Pitigalaarachchi, P. A. P. M. B.
    Pasqual, A.
    TENCON 2017 - 2017 IEEE REGION 10 CONFERENCE, 2017, : 2620 - 2625