Cervical spine motion:: a fluoroscopic comparison of Shikani Optical Stylet® vs Macintosh laryngoscope

被引:0
|
作者
Turkstra, Timothy P.
Pelz, David M.
Shaikh, A. Allison
Craen, Rosemary A.
机构
[1] Univ Western Ontario, Hlth Sci Ctr, Dept Anesthesia & Perioperat Med, London, ON N6A 5A5, Canada
[2] Univ Western Ontario, Dept Diagnost Radiol & Nucl Med, Neuroradiol Sect, London, ON N6A 5A5, Canada
关键词
D O I
10.1007/BF03022029
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Purpose: The optimal technique to manage the airway in patients presenting with a potential or documented cervical spine (C-spine) injury remains unresolved. Using fluoroscopic video assessment, C-spine motion during laryngoscopy with a Shikani Optical Stylet((R)) (SOS) was compared to C-spine motion during intubation using a Macintosh blade. Methods: Twenty-four healthy surgical patients gave written consent to participate in a crossover randomized controlled trial; all patients were subjected to both Macintosh and Shikani laryngoscopy with manual inline stabilization following induction of anesthesia. The C-spine motion was examined at four areas: the occiput-C1 junction, C1-C2 junction, C2-C5 motion segment, and C5-thoracic motion segment. The time required for laryngoscopy was also measured (duration > 120 sec was deemed a failure of the laryngoscopy technique). Results: On average, C-spine motion was 52% less (P < 0.02) at three of the motion segments studied, occiput-C1, C2-C5, and C5-thoracic when comparing SOS vs Macintosh laryngoscopy. There was no difference between techniques at the C1-C2 segment. Laryngoscopy with SOS (28 17 sec) took longer than with Macintosh blade (17 +/- 7 sec), P < 0.01. There were two failures out of 23 using the SOS, vs none with the Macintosh blade. Conclusion: For patients in whom C-spine movement is undesirable, use of the SOS may limit neck movement, while modestly increasing the time required to intubate, and/or the risk of procedure failure.
引用
收藏
页码:441 / 447
页数:7
相关论文
共 50 条
  • [21] Intubation Biomechanics Laryngoscope Force and Cervical Spine Motion during Intubation with Macintosh and Airtraq Laryngoscopes
    Hindman, Bradley J.
    Santoni, Brandon G.
    Puttlitz, Christian M.
    From, Robert P.
    Todd, Michael M.
    ANESTHESIOLOGY, 2014, 121 (02) : 260 - 271
  • [22] Endotracheal intubation with Optical Stylet Vs Macintosh Laryngoscope performed on a manikin by medical students: A prospective manikin trial
    Yilmaz, Atakan
    Kekec, Abuzer
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2019, 69 (11) : 1651 - 1656
  • [23] Comparative Performance of GlideScope Video Laryngoscope and Macintosh Laryngoscope in Children With Immobilized Cervical Spine
    Cui, Xin-Long
    Xue, Fu-Shan
    Cheng, Yi
    Li, Rui-Ping
    PEDIATRIC EMERGENCY CARE, 2013, 29 (05) : 690 - 690
  • [24] A comparison of the Trachway intubating stylet and the Macintosh laryngoscope in tracheal intubation: a manikin study
    Kuo-Chuan Hung
    Ping-Heng Tan
    Victor Chia-Hsiang Lin
    Hao-Kuang Wang
    Hung-Shu Chen
    Journal of Anesthesia, 2013, 27 : 205 - 210
  • [25] Comparison of Trachway® intubating stylet and Macintosh laryngoscope in tracheal intubation: A manikin study
    Shyr, M. -H.
    Ong, J.
    Lee, C. -L.
    Lai, H. -Y.
    Chen, T. -Y.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (01) : 268 - 268
  • [26] A comparison of the Trachway intubating stylet and the Macintosh laryngoscope in tracheal intubation: a manikin study
    Hung, Kuo-Chuan
    Tan, Ping-Heng
    Lin, Victor Chia-Hsiang
    Wang, Hao-Kuang
    Chen, Hung-Shu
    JOURNAL OF ANESTHESIA, 2013, 27 (02) : 205 - 210
  • [27] Movement of the upper cervical spine during laryngoscopy: a comparison of the Bonfils intubation fibrescope and the Macintosh laryngoscope
    Rudolph, C
    Schneider, JP
    Wallenborn, J
    Schaffranietz, L
    ANAESTHESIA, 2005, 60 (07) : 668 - 672
  • [28] Comparison of Intubrite and Macintosh laryngoscope use in immobilized cervical spine by novice nurses. A mannequin trial
    Czekajlo, Michael S.
    Zawada, Bartosz
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2018, 36 (05): : 879 - 880
  • [29] Intubation with cervical spine immobilisation: a comparison between the KingVision videolaryngoscope and the Macintosh laryngoscope: A randomised controlled trial
    Aleksandrowicz, Dawid
    Wieczorek, Andrzej
    Gaszynski, Tomasz
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2018, 35 (05) : 399 - 401
  • [30] The Shikani Optical Stylet as an Alternative to Awake Fiberoptic Intubation in Patients at Risk of Secondary Cervical Spine Injury: A Randomized Controlled Trial
    Mahrous, Rabab S. S.
    Ahmed, Aly M. M.
    JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 2018, 30 (04) : 354 - 358