Intra- and inter-reliability of fleximetry in individuals with chronic shoulder pain

被引:8
|
作者
da Silva, Iran Henrique [1 ]
da Silva Junior, Jose Mariedson [1 ]
Santos-de-Araujo, Aldair Darlan [1 ]
Fidelis de Paula Gomes, Cid Andre [2 ]
Souza, Cesario da Silva [1 ]
Alves de Souza Matias, Priscila Helena Vanin [1 ]
Dibai-Filho, Almir Vieira [3 ]
机构
[1] Tiradentes Univ Ctr, Dept Phys Therapy, Maceio, AL, Brazil
[2] Nove de Julho Univ, Dept Phys Therapy, Sao Paulo, SP, Brazil
[3] Univ Fed Maranhao, Dept Phys Educ, Sao Luis, MA, Brazil
关键词
Shoulder joint; Shoulder impingement syndrome; Reproducibility of results; Chronic pain; IMPINGEMENT SYNDROME; SCAPULAR DYSKINESIS; MOTION MEASUREMENT; RANGE; SMARTPHONE; DISABILITY; AGREEMENT; INJURIES; STRENGTH;
D O I
10.1016/j.ptsp.2018.05.011
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To evaluate the intra- and inter-rater reliability of fleximetry in the measurement of range of motion (ROM) in individuals with chronic shoulder pain. Design: Reliability study. Setting: Physiotherapy clinic. Participants: Thirty individuals of both genders, ages between 18 and 45 years, with chronic shoulder pain. Main outcome measures: Fleximetry was used to measurement shoulder ROM (flexion, hyperextension, abduction, medial and lateral rotation, and horizontal abduction and adduction). Two examiners performed the evaluations of the shoulder ROM at two time points (interval of one week between them). Results: In the intra-rater reliability, substantial to excellent reliability was found, with intraclass correlation coefficient (ICC) values ranging from 0.79 to 0.92, standard error of the measurement (SEM) values ranging from 5.70 to 8.72 degrees, and minimum detectable change (MDC) values varying between 15.80 and 25.18 degrees. Regarding the inter-rater reliability, moderate to excellent reliability was observed, with ICC values ranging from 0.68 to 0.96, SEM values ranging from 4.98 to 11.53 degrees, and MDC values ranging from 13.82 to 31.97 degrees. Conclusion: The use of the fleximeter to measure shoulder ROM presents acceptable reliability values in individuals with chronic shoulder pain, which supports the use of this method of evaluation in research and clinical practice. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:115 / 120
页数:6
相关论文
共 50 条
  • [41] Intra- and inter-rater reliability of the Multiple Sclerosis Functional Composite
    Fischer, JS
    Cohen, JA
    Cutter, GR
    Mertz, LA
    Bolibrush, DM
    Skaramagas, TT
    Jak, AJ
    Kniker, JE
    NEUROLOGY, 1999, 52 (06) : A548 - A548
  • [42] The intra- and inter-rater reliability of five clinical muscle performance tests in patients with and without neck pain
    Tina Juul
    Henning Langberg
    Flemming Enoch
    Karen Søgaard
    BMC Musculoskeletal Disorders, 14
  • [43] Intra- and Inter-Session Reliability of Methods for Measuring Reaction Time in Participants with and without Patellofemoral Pain Syndrome
    Zeinalzadeh, Afsaneh
    Nazary-Moghadam, Salman
    Hoseinian, Sayyed Hadi Sayyed
    Ebrahimzadeh, Mohammad H.
    Imani, Esmaeel
    Karimpour, Samira
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2021, 9 (01): : 106 - 113
  • [44] Upper Limb Neurodynamic Test 1 on Healthy Individuals: Intra- and Intersession Reliability of the Angle between Pain Onset and Submaximal Pain
    Leoni, Diego
    Storer, Davide
    Gatti, Roberto
    Egloff, Michele
    Barbero, Marco
    PAIN RESEARCH & MANAGEMENT, 2016, 2016 : 1 - 7
  • [45] Intra- and inter-rater reliability of the assessment of capacity for myoelectric control
    Hermansson, LM
    Bodin, L
    Eliasson, AC
    JOURNAL OF REHABILITATION MEDICINE, 2006, 38 (02) : 118 - 123
  • [46] Intra- and inter-rater reliability in ultrasonographic measurements of coracohumeral distance
    Guerra-Rodriguez, Diego
    Guerrero-Henriquez, Juan
    Basilio, Daniel
    Mendez-Rebolledo, Guillermo
    MUSCULOSKELETAL SCIENCE AND PRACTICE, 2024, 69
  • [47] Intra- and inter-tester reliability and reference values for hand strength
    Peolsson, A
    Hedlund, R
    Öberg, B
    JOURNAL OF REHABILITATION MEDICINE, 2001, 33 (01) : 36 - 41
  • [48] INTRAOBSERVER INTRA- AND INTER-METHOD RELIABILITY IN BREAST DENSITY MEASUREMENTS
    Jobling, Judith M.
    D'Este, Catherine A.
    Forbes, John F.
    ASIA-PACIFIC JOURNAL OF CLINICAL ONCOLOGY, 2014, 10 : 14 - 15
  • [49] Intra- and inter-rater reliability, agreement, and minimal detectable change of the handheld dynamometer in individuals with symptomatic hip osteoarthritis
    Vaz, Gilvan Ferreira
    Freire, Felipe Florencio
    Goncalves, Henrique Mansur M.
    de Aviz, Marcus Alexandre Brito M.
    Martins, Wagner Rodrigues M.
    Durigan, Joao Luiz Quagliotti M.
    PLOS ONE, 2023, 18 (06):
  • [50] Test-Retest Reliability of Pain Sensitivity Measures in Individuals with Shoulder Pain
    Othman, Rani
    Bajaber, Abdulrahman Mohammed
    Alhabshi, Anas Mohammed
    Albadi, Majed
    Aldhabi, Rawan
    Almaddah, Muataz
    Alqarni, Abdullah
    JOURNAL OF PAIN RESEARCH, 2024, 17 : 1917 - 1927