High-spatial-resolution contrast-enhanced MR angiography of the intracranial venous system with fourfold accelerated two-dimensional sensitivity encoding

被引:19
|
作者
Hu, Houchun H. [1 ]
Campeau, Norbert G. [1 ]
Huston, John, III [1 ]
Kruger, David G. [1 ]
Haider, Clifton R. [1 ]
Riederer, Stephen J. [1 ]
机构
[1] Mayo Clin & Mayo Fdn, Coll Med, Dept Radiol, Magnet Resonance Lab, Rochester, MN 55905 USA
关键词
D O I
10.1148/radiol.2433060819
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Informed consent was obtained; the study was HIPAA compliant and institutional review board approved. Fourfold accelerated (FFA) two-dimensional (2D) sensitivity encoding (SENSE) (65 seconds) was prospectively compared with its nonaccelerated counterpart (4 minutes 20 seconds) for diagnostic image quality and sharpness of visualization of blood vessels at 1.5 T with three-dimensional (3D) intracranial contrast-enhanced magnetic resonance venography in 18 consecutive volunteers (10 men, eight women; mean age, 48.4 years) and two patients (55-year-old man, 30-year-old woman). Two readers compared FFA 2D SENSE results with results from its nonaccelerated counterpart; they rated visualization of large and medium sinuses as equivalent (P > .1) and that of small deep cerebral veins (P < .01) and superficial cerebral veins (P < .001) as superior. Overall diagnostic image quality ratings were excellent for 62% and 80% of nonaccelerated and FFA 2D SENSE results, respectively (P < .05). FFA 2D SENSE may become the method of choice for fast visualization of intracranial venous vasculature in clinical practice.
引用
收藏
页码:853 / 861
页数:9
相关论文
共 50 条
  • [31] High-spatial-resolution lower extremity MR angiography at 3.0 T: Contrast agent dose comparison study
    Habibi, Reza
    Krishnam, Mayil S.
    Lohan, Derek G.
    Barkhordarian, Fatemeh
    Jalili, Mehdi
    Saleh, Roya S.
    Ruehm, Stefan G.
    Finn, J. Paul
    RADIOLOGY, 2008, 248 (02) : 680 - 692
  • [32] Undersampled elliptical centric view-order for improved spatial resolution in contrast-enhanced MR angiography
    Madhuranthakam, AJ
    Hu, HCH
    Barger, AV
    Haider, CR
    Kruger, DG
    Glockner, JF
    Huston, J
    Riederer, SJ
    MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (01) : 50 - 58
  • [33] Three-dimensional contrast-enhanced MR angiography of the extracranial carotid arteries: Two techniques
    Levy, RA
    Maki, JH
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1998, 19 (04) : 688 - 690
  • [34] High resolution 3 Tesla contrast-enhanced MR angiography of the hands in Raynaud’s disease
    J. Walcher
    R. Strecker
    S. Goldacker
    J. Winterer
    M. Langer
    T. A. Bley
    Clinical Rheumatology, 2007, 26 : 587 - 589
  • [35] High resolution 3 Tesla contrast-enhanced MR angiography of the hands in Raynaud's disease
    Walcher, J.
    Strecker, R.
    Goldacker, S.
    Winterer, J.
    Langer, M.
    Bley, T. A.
    CLINICAL RHEUMATOLOGY, 2007, 26 (04) : 587 - 589
  • [36] Free-Breathing High-Spatial-Resolution Delayed Contrast-Enhanced Three-Dimensional Viability MR Imaging of the Myocardium at 3.0T: A Feasibility Study
    Amano, Yasuo
    Matsumura, Yoshio
    Kumita, Shinichiro
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (06) : 1361 - 1367
  • [37] Multistation whole-body high-spatial-resolution MR angiography using a 32-channel MR system
    Nael, Kambiz
    Ruehm, Stefan G.
    Michaely, Henrik J.
    Saleh, Roya
    Lee, Margaret
    Laub, Gerhard
    Finn, J. Paul
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (02) : 529 - 539
  • [38] On improving temporal and spatial resolution of 3D contrast-enhanced body MR angiography with parallel imaging
    Chen, Q
    Quijano, CV
    Mai, VM
    Krishnamoorthy, SK
    Li, W
    Storey, P
    Edelman, RR
    RADIOLOGY, 2004, 231 (03) : 893 - 899
  • [39] High-resolution breath-hold contrast-enhanced MR angiography of the entire carotid circulation
    Carr, JC
    Ma, J
    Desphande, V
    Pereles, S
    Laub, G
    Finn, JP
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (03) : 543 - 549
  • [40] Utilizing SENSE to reduce scan duration in high-resolution contrast-enhanced renal MR angiography
    Wilson, Gregory J.
    Eubank, William B.
    Vasbinder, G. Boudewijn C.
    Kessels, Alfons G. H.
    Hoogeveen, Romhild M.
    Muthupillai, Raja
    Maki, Jeffrey H.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (04) : 873 - 879