Parametric Trough Solar Collector With Commercial Evacuated Receiver: Performance Comparison at Plant Level

被引:4
|
作者
Nunez Bootello, Juan Pablo [1 ]
Schramm, Markus
Silva Perez, Manuel [1 ,2 ]
Doblare Castellano, Manuel [1 ]
机构
[1] Abengoa, Calle Energia Solar 1, Seville 41014, Spain
[2] Univ Seville, Dept Energy Engn, Grp Thermodynam & Renewable Energy, Seville 41004, Spain
关键词
parabolic trough; solar thermal energy; solar thermal power plant; nonimaging optics; concentrated solar power; optical efficiency; thermal efficiency;
D O I
10.1115/1.4036934
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A new anidolic parametric trough solar collector (PmTC) having 8.12m net width aperture has been recently proposed for a commercial evacuated receiver tube with an absorber diameter of 70 mm. Since the collector was designed ignoring transmission, absorption, and reflection optical losses, calculations of the optical efficiency and the incidence angle modifier (IAM) by means of Monte Carlo spectral raytracing simulations using real slope errors distributions and taking into account Fresnel reflection losses were done. Comparison with an Eurotrough parabolic trough collector (PTC) shows an optical penalization of 5.1% due to the reflectivity and additional soiling of the secondary mirror, to an increase in the end losses and to the Fresnel reflection losses. The National Renewable Energy Laboratory (NREL) system advisor model (SAM) was used to perform annual simulations of two commercial 50 MWe oil power plants without thermal energy storage located in Seville. A PTC solar field consisting of 90 loops, each one having four Eurotrough solar collector assemblies (SCA) with 150m length was first modeled resulting in a gross production of 386 kWh/(m(2) yr). A PmTC solar field with the same module length and similar SCA net aperture area was also simulated. A final configuration of 94 loops and four SCAs with 100m length per loop yields a gross production of 379 kWh/(m(2) yr) showing no improvement compared to the reference PTC plant. The present study allows to advance in the understanding of the potential of the anidolic optic to produce optical geometries able to effectively improve the PTC technology in the short-term projecting results at a commercial plant level.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Annual performance of evacuated tubular collector integrated solar still
    Dev, Rahul
    Tiwari, G. N.
    DESALINATION AND WATER TREATMENT, 2012, 41 (1-3) : 204 - 223
  • [42] Comparison and evaluation of energetic and exergetic performance of an evacuated tube solar collector using various nanofluid
    Tong, Yijie
    Wang, Ruijin
    Wang, Shifeng
    Wang, Huijiao
    Huang, Lizhong
    Shao, Chun
    Jin, Xiao
    Xue, Bing
    Zhu, Zefei
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2023, 174 : 585 - 594
  • [43] Performance comparison of dish solar collector system with mirror arrays and receiver shapes
    Seo, Taebeom
    Cho, Hyunseok
    Oh, Sangjune
    Lee, Juhan
    Kang, Yongheack
    Han, Guiyoung
    PROGRESS IN COMPUTATIONAL FLUID DYNAMICS, 2009, 9 (3-5): : 208 - 216
  • [44] Thermal performance of a solar pressure cooker based on evacuated tube solar collector
    Kumar, R
    Adhikari, RS
    Garg, HP
    Kumar, A
    APPLIED THERMAL ENGINEERING, 2001, 21 (16) : 1699 - 1706
  • [45] Numerical study of heat loss from a non-evacuated receiver of a solar collector
    Patil, Ramchandra G.
    Kale, Dhanaji M.
    Panse, Sudhir V.
    Joshi, Jyeshtharaj B.
    ENERGY CONVERSION AND MANAGEMENT, 2014, 78 : 617 - 626
  • [46] Preliminary performance study of a high-temperature parabolic trough solar evacuated receiver with an inner transparent radiation shield
    Wang, Qiliang
    Yang, Honglun
    Hu, Mingke
    Huang, Xiaona
    Li, Jing
    Pei, Gang
    SOLAR ENERGY, 2018, 173 : 640 - 650
  • [47] Performance of evacuated tube solar collector integrated solar desalination unit - a review
    Kumar, Rajeev
    Singh, Desh Bandhu
    Dewangan, Ashish
    Singh, Vivek Kumar
    Kumar, Navneet
    DESALINATION AND WATER TREATMENT, 2021, 230 : 92 - 115
  • [48] Analysis of Annual Performance of a Parabolic Trough Solar Collector
    Liang, Hongbo
    Zheng, Chenxiao
    Zheng, Wandong
    You, Shijun
    Zhang, Huan
    8TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY (ICAE2016), 2017, 105 : 888 - 894
  • [49] Performance Investigation of Solar Parabolic Trough Collector Alternatives
    Drira, Youssef
    Fakhfakh, Nadim
    Jribi, Skander
    Bentaher, Hatem
    Benhassine, Ilyes
    Ammar, Lotfi
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2023, 48 (09) : 11323 - 11331
  • [50] PERFORMANCE EVALUATION OF NANOFLUID ON PARABOLIC TROUGH SOLAR COLLECTOR
    Vijayan, Gopalsamy
    Rajasekaran, Karunakaran
    THERMAL SCIENCE, 2020, 24 (02): : 853 - 864