Results at a minimum follow-up of 5 years of a ligaments-compatible total ankle replacement design

被引:14
|
作者
Giannini, Sandro [1 ]
Romagnoli, Matteo [2 ]
Barbadoro, Paolo [1 ]
Muccioli, Giulio Maria Marcheggiani [2 ]
Cadossi, Matteo [1 ]
Grassi, Alberto [2 ]
Zaffagnini, Stefano [2 ]
机构
[1] Ist Ortoped Rizzoli, Dept Orthopaed Surg, Bologna, Italy
[2] Ist Ortoped Rizzoli, Dept Orthopaed Surg, Dipartimento Rizzoli Sicilia, SS 113,Km 246, I-90011 Bagheria, Italy
关键词
Ankle; Replacement; Arthritis; Trauma; LONG-TERM; ARTHROPLASTY; RATES; OSTEOARTHRITIS; COMPLICATIONS; ARTHRODESIS; MOBILITY; MOTION; RANGE;
D O I
10.1016/j.fas.2017.03.009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: A new design of 3-part ankle replacement was developed to achieve compatibility with the natural ligaments by allowing certain fibers to remain isometric during passive motion. Methods: We evaluate 75 ankle prostheses implanted from July 2003 to December 2008, at a mean follow-up 6.5 +/- 1.1 years ( range 5-9 years). The mean age at surgery was 62 +/- 13 years ( range 29-82). Results: The mean AOFAS scores achieved at pre-op and at last follow-up were respectively 37 +/- 5 ( 23-45) and 78 +/- 8 ( 64-98). ( p < 0.001). Clinical range of motion of the ankle measured by goniometer pre op was 1 degrees +/- 2 of dorsiflexion and 12 degrees +/- 4 degrees of plantarflexion; at last follow- up range of motion increased to 6 degrees +/- 5 degrees in dorsiflexion ( p < 0.01) and 18 degrees +/- 7 degrees in plantarflexion ( p < 0.05). Radiographs showed no loosening and little signs of radiolucency. Two revisions necessitated component removal, neither for implant loosening. The overall survival rate was 97.3%. Conclusions: Function and Range-of-motion showed significant improvements. These results demonstrate that ligaments-compatible shaped talar and tibial components, with a fully conforming interposed meniscal bearing, can provide satisfactory survival rates and clinical outcomes in the middle term. (C) 2017 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:116 / 121
页数:6
相关论文
共 50 条
  • [21] Results of a series of 113 ACADEMIA total knee prostheses with a follow-up at 5 years
    Philippe, M.
    Petit, R.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2008, 18 (04): : 269 - 278
  • [22] Percutaneous surgery with balloon for tibial plateau fractures, results with a minimum of 5 years of follow-up
    Vendeuvre, Tanguy
    Ferriere, Victor
    Bouget, Pierre
    Billot, Maxime
    Germaneau, Arnaud
    Severyns, Mathieu
    Roulaud, Manuel
    Rigoard, Philippe
    Pries, Pierre
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (07): : 2650 - 2656
  • [23] Total femur replacement with 18 years of follow-up: A case report
    Yang, Yi-Hao
    Chen, Jia-Xiang
    Chen, Qiu-Yun
    Wang, Yu
    Zhou, Yao-Bin
    Wang, Hong-Wei
    Yuan, Tao
    Sun, Hong-Pu
    Xie, Lin
    Yao, Zhi-Hong
    Yang, Zuo-Zhang
    WORLD JOURNAL OF CLINICAL CASES, 2022, 10 (15) : 4957 - 4963
  • [24] Excellent results of restricted kinematic alignment total knee arthroplasty at a minimum of 10 years of follow-up
    Morcos, Mina W.
    Beckers, Gautier
    Salvi, Andrea Giordano
    Bennani, Mourad
    Masse, Vincent
    Vendittoli, Pascal-Andre
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2025, 33 (02) : 654 - 665
  • [25] Clinical results of alumina medial pivot total knee arthroplasty at a minimum follow-up of 10 years
    Nakamura, Suguru
    Minoda, Yukihide
    Nakagawa, Shigeru
    Kadoya, Yoshinori
    Takemura, Susumu
    Kobayashi, Akio
    Mizokawa, Shigekazu
    Ohta, Yoichi
    Takahashi, Sinji
    Yamamura, Kazumasa
    Nakamura, Hiroaki
    KNEE, 2017, 24 (02): : 434 - 438
  • [26] Results of Charnley total hip arthroplasty at a minimum of thirty years - A concise follow-up of a previous report
    Callaghan, JJ
    Templeton, JE
    Liu, SS
    Pedersen, DR
    Goetz, DD
    Sullivan, PM
    Johnston, RC
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (04): : 690 - 695
  • [27] Total femur replacement with 18 years of follow-up: A case report
    Yi-Hao Yang
    Jia-Xiang Chen
    Qiu-Yun Chen
    Yu Wang
    Yao-Bin Zhou
    Hong-Wei Wang
    Tao Yuan
    Hong-Pu Sun
    Lin Xie
    Zhi-Hong Yao
    Zuo-Zhang Yang
    World Journal of Clinical Cases, 2022, 10 (15) : 4957 - 4963
  • [28] The early results of high-flex total knee arthroplasty - A minimum of 2 years of follow-up
    Huang, HT
    Su, AY
    Wang, GJ
    JOURNAL OF ARTHROPLASTY, 2005, 20 (05): : 674 - 679
  • [29] Outcome after total ankle arthroplasty with a minimum of five years follow-up: A systematic review and meta-analysis
    Onggo, James Randolph
    Nambiar, Mithun
    Phan, Kevin
    Hickey, Benjamin
    Galvin, Michael
    Bedi, Harvinder
    FOOT AND ANKLE SURGERY, 2020, 26 (05) : 556 - 563
  • [30] Results of unicompartmental knee arthroplasty at a minimum of ten years of follow-up
    Berger, RA
    Meneghini, RM
    Jacobs, JJ
    Sheinkop, MB
    Della Valle, CJ
    Rosenberg, AG
    Galante, JO
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (05): : 999 - 1006