Pulse sequences for T1- and T1T2-contrast enhancement in NMR imaging

被引:0
|
作者
Andreev, NK
Khakimov, AM
Idiyatullin, DI
机构
[1] Moscow Power Res Inst, Kazan Branch, Kazan 420066 66, Tatarstan, Russia
[2] Kazan Acad Architecture & Civil Engn, Kazan 420043 43, Tatarstan, Russia
[3] Kazan Inst Biol, Kazan 420503, Tatarstan, Russia
关键词
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Probing pulse sequences of the type 90 degrees-tau(0)-180 degrees-tau(1)-...180 degrees-tau(n) with optimized intervals tau(i) provide a higher T-1-contrast in the NMR imaging compared to that obtained using the saturation-recovery or stimulated echo pulse sequences. Signals obtained with the proposed pulse sequences, unlike that for the inversion-recovery sequence, do not change sign and provide more reliable information. The new pulse sequences serve as fillers that select only signals with short relaxation times T-1. The filter bandwidth increases with the number of RF pulses in the sequence. It is suggested that the new sequences can be used in combination with the CPMG pulse sequence to provide the T1T2-contrast. The domain of interest, in which the T1T2-contrast is enhanced, is determined by measuring two time intervals in the combined pulse sequence. In the first interval, the signal reaches a preset level in the course of the spin-lattice relaxation, and during the second interval, a preset level is attained for the spin-spin relaxation.
引用
收藏
页码:251 / 256
页数:6
相关论文
共 50 条
  • [41] EFFECT OF AGGREGATION ON RADIATIVE (T1-]S0) AND NONRADIATIVE (T1-]S0 AND S1-]T1) TRANSITIONS IN XANTHENE DYES
    JOSHI, NB
    PANT, DD
    JOURNAL OF LUMINESCENCE, 1976, 14 (01) : 1 - 8
  • [42] TOWARD AN AUTOMATED-ANALYSIS SYSTEM FOR NUCLEAR-MAGNETIC-RESONANCE IMAGING .1. EFFICIENT PULSE SEQUENCES FOR SIMULTANEOUS T1-T2 IMAGING
    ODONNELL, M
    GORE, JC
    ADAMS, WJ
    MEDICAL PHYSICS, 1986, 13 (02) : 182 - 190
  • [43] A note on almost periodic points and minimal sets in T1- and T2-spaces
    Mai, Jie-Hua
    Liu, Xin-He
    DISCRETE DYNAMICS IN NATURE AND SOCIETY, 2008, 2008
  • [44] Coherence transfer and electron T1-, T2-relaxation in nitroxide spin labels
    Marsh, Derek
    JOURNAL OF MAGNETIC RESONANCE, 2017, 277 : 86 - 94
  • [45] Reducing Metallic Artifacts in Postoperative Spinal Imaging: Usefulness of IDEAL Contrast-enhanced T1- and T2-weighted MR Imaging-Phantom and Clinical Studies
    Cha, Jang Gyu
    Jin, Wook
    Lee, Min Hee
    Kim, Dong Hoon
    Park, Jai Soung
    Shin, Won Han
    Yi, Boem Ha
    RADIOLOGY, 2011, 259 (03) : 885 - 893
  • [46] T1-/T2-weighted ratio differs in demyelinated cortex in multiple sclerosis
    Nakamura, Kunio
    Chen, Jacqueline T.
    Ontaneda, Daniel
    Fox, Robert J.
    Trapp, Bruce D.
    ANNALS OF NEUROLOGY, 2017, 82 (04) : 635 - 639
  • [47] Gadolinium hybrid iron oxide nanocomposites for dual T1- and T2-weighted MR imaging of cell labeling
    Zeng, Yun
    Wang, Liqin
    Zhou, Zijian
    Wang, Xiaoyong
    Zhang, Yang
    Wang, Junqing
    Mi, Peng
    Liu, Gang
    Zhou, Liming
    BIOMATERIALS SCIENCE, 2017, 5 (01) : 50 - 56
  • [48] The interplay of T1- and T2-relaxation on T1-weighted MRI of hMSCs induced by Gd-DOTA-peptides
    Cao, Limin
    Li, Binbin
    Yi, Peiwei
    Zhang, Hailu
    Dai, Jianwu
    Tan, Bo
    Deng, Zongwu
    BIOMATERIALS, 2014, 35 (13) : 4168 - 4174
  • [49] Dynamic contrast-enhanced magnetic resonance imaging of the kidney: Comparison of T1-weighted and T2*-weighted sequences
    Tsushima, Y
    Niemi, P
    Komu, M
    Dean, PB
    Haapanen, A
    Kormano, M
    ACADEMIC RADIOLOGY, 1996, 3 : S176 - S178
  • [50] OPTIMAL PULSE SEQUENCES FOR MAGNETIC-RESONANCE-IMAGING - COMPUTING ACCURATE T1, T2, AND PROTON DENSITY IMAGES
    IWAOKA, H
    HIRATA, T
    MATSUURA, H
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1987, 6 (04) : 360 - 369