Pulse sequences for T1- and T1T2-contrast enhancement in NMR imaging

被引:0
|
作者
Andreev, NK
Khakimov, AM
Idiyatullin, DI
机构
[1] Moscow Power Res Inst, Kazan Branch, Kazan 420066 66, Tatarstan, Russia
[2] Kazan Acad Architecture & Civil Engn, Kazan 420043 43, Tatarstan, Russia
[3] Kazan Inst Biol, Kazan 420503, Tatarstan, Russia
关键词
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Probing pulse sequences of the type 90 degrees-tau(0)-180 degrees-tau(1)-...180 degrees-tau(n) with optimized intervals tau(i) provide a higher T-1-contrast in the NMR imaging compared to that obtained using the saturation-recovery or stimulated echo pulse sequences. Signals obtained with the proposed pulse sequences, unlike that for the inversion-recovery sequence, do not change sign and provide more reliable information. The new pulse sequences serve as fillers that select only signals with short relaxation times T-1. The filter bandwidth increases with the number of RF pulses in the sequence. It is suggested that the new sequences can be used in combination with the CPMG pulse sequence to provide the T1T2-contrast. The domain of interest, in which the T1T2-contrast is enhanced, is determined by measuring two time intervals in the combined pulse sequence. In the first interval, the signal reaches a preset level in the course of the spin-lattice relaxation, and during the second interval, a preset level is attained for the spin-spin relaxation.
引用
收藏
页码:251 / 256
页数:6
相关论文
共 50 条
  • [1] New pulse sequences for T1- and T1/T2-contrast enhancing in NMR imaging
    Andreev, NK
    Hakimov, AM
    Idiyatullin, DS
    MAGNETIC RESONANCE IMAGING, 1998, 16 (08) : 981 - 987
  • [2] T1- and T2-weighted imaging at 8 tesla
    Kangarlu, A
    Abduljalil, AM
    Robitaille, PML
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 (06) : 875 - 878
  • [3] MR IMAGING OF LIVER METASTASES AT 1.5 T - SIMILAR CONTRAST DISCRIMINATION WITH T1-AND T2-WEIGHTED PULSE SEQUENCES
    SAINI, S
    LI, W
    WALLNER, B
    HAHN, PF
    EDELMAN, RR
    RADIOLOGY, 1991, 181 (02) : 449 - 453
  • [4] Potential for misinterpretation of combined T1- and T2-weighted contrast-enhanced MR imaging of cartilage
    Burstein, D
    Williams, A
    McKenzie, C
    RADIOLOGY, 2004, 233 (02) : 619 - 621
  • [5] Potential for misinterpretation of combined T1- and T2-weighted contrast-enhanced MR imaging of cartilage - Respond
    Woertler, K
    Rummeny, EJ
    RADIOLOGY, 2004, 233 (02) : 621 - 622
  • [6] On T1- and T2-productable compact spaces
    Morayne, Michal
    Ralowski, Robert
    GEORGIAN MATHEMATICAL JOURNAL, 2022, 29 (03) : 441 - 443
  • [7] Clinical utility of optimized three-dimensional T1-, T2-, and T2*-weighted sequences in spinal magnetic resonance imaging
    Nobuko Tanitame
    Keizo Tanitame
    Kazuo Awai
    Japanese Journal of Radiology, 2017, 35 : 135 - 144
  • [8] Clinical utility of optimized three-dimensional T1-, T2-, and T2*-weighted sequences in spinal magnetic resonance imaging
    Tanitame, Nobuko
    Tanitame, Keizo
    Awai, Kazuo
    JAPANESE JOURNAL OF RADIOLOGY, 2017, 35 (04) : 135 - 144
  • [9] Correlation of T1- to T2-weighted signal intensity ratio with T1- and T2-relaxation time and IDH mutation status in glioma
    Takahiro Sanada
    Shota Yamamoto
    Mio Sakai
    Toru Umehara
    Hirotaka Sato
    Masato Saito
    Nobuyuki Mitsui
    Satoru Hiroshima
    Ryogo Anei
    Yonehiro Kanemura
    Mishie Tanino
    Katsuyuki Nakanishi
    Haruhiko Kishima
    Manabu Kinoshita
    Scientific Reports, 12
  • [10] Should (T1- T2) have larger uncertainty than T1?
    Guthrie, WF
    TEMPMEKO 2001: 8TH INTERNATIONAL SYMPOSIUM ON TEMPERATURE AND THERMAL MEASUREMENT IN INDUSTRY AND SCIENCE, VOL 1 & 2, PROCEEDINGS, 2002, : 887 - 892