A Measurement and Accuracy Evaluation Method for Internal Dam Settlement

被引:1
|
作者
Lv, Shiwang [1 ]
Chen, Zhipeng [2 ]
Li, Qingquan [2 ]
Luo, Tianwen [3 ]
Xu, Rui [3 ]
Yin, Yu [1 ]
机构
[1] Shenzhen Univ, Coll Civil & Transportat Engn, Shenzhen, Peoples R China
[2] Shenzhen Univ, Guangdong Key Lab Urban Informat, Shenzhen, Peoples R China
[3] Guizhou Survey Design Inst Water Resources & Hydr, Guiyang, Peoples R China
基金
中国国家自然科学基金;
关键词
pipeline measurement; pipeline robot; rockfill dam; internal deformation; inertial measurement;
D O I
10.1109/ICMSR2020.2022.00012
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Dams are an important part of the transportation infrastructure. There are many deficiencies in the traditional methods for monitoring the internal deformation of rockfill dams, and it is difficult for the traditional methods to meet the needs of 300m ultra-high rockfill dams. In this paper, we propose a method of internal settlement measurement and accuracy evaluation of rockfill dam based on a pipeline robot. The results of the accuracy evaluation show that the method of internal settlement measurement and accuracy evaluation of rockfill dam based on a pipeline robot has great internal precision and external accuracy, reaching 10.53 ppm and 11.9 ppm, respectively. This method has better validity, stability, and accuracy than the traditional monitoring method based on the water level settlement gauge and is a new internal deformation monitoring method for rockfill dams with good application prospects.
引用
收藏
页码:20 / 24
页数:5
相关论文
共 50 条
  • [21] Study on distributed monitoring technology for internal settlement of rockfill dam using fiber optic gyroscope
    Liao C.
    Cai D.
    Li M.
    Lin J.
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2024, 57 (02): : 77 - 86
  • [22] In situ measurement of rockfill dam settlement using fiber optic gyroscope monitoring system
    Liao, Cheng
    Luo, Weili
    Cai, Desuo
    Li, Miao
    STRUCTURAL CONTROL & HEALTH MONITORING, 2022, 29 (04):
  • [23] In situ measurement of rockfill dam settlement using fiber optic gyroscope monitoring system
    Liao, Cheng
    Luo, Weili
    Cai, Desuo
    Li, Miao
    Structural Control and Health Monitoring, 2022, 29 (04)
  • [24] Measurement of the internal cell temperature via impedance: Evaluation and application of a new method
    Schmidt, Jan Philipp
    Arnold, Stefan
    Loges, Andre
    Werner, Daniel
    Wetzel, Thomas
    Ivers-Tiffee, Ellen
    JOURNAL OF POWER SOURCES, 2013, 243 : 110 - 117
  • [25] Investigation of Sabalan Earth Dam Settlement at First Filling by Finite Difference Method
    Tarinejad, Reza
    Alizadeh-Arasi, Okhtay
    Isari, Mohsen
    Foumani, Ramtin Sobhkhiz
    TRANSPORTATION INFRASTRUCTURE GEOTECHNOLOGY, 2021, 8 (03) : 473 - 490
  • [26] Investigation of Sabalan Earth Dam Settlement at First Filling by Finite Difference Method
    Reza Tarinejad
    Okhtay Alizadeh-Arasi
    Mohsen Isari
    Ramtin Sobhkhiz Foumani
    Transportation Infrastructure Geotechnology, 2021, 8 : 473 - 490
  • [27] System for High Accuracy Internal Quantum Efficiency Measurement
    Ciocan, R.
    Li, Z.
    Feldman, A.
    Donohue, J.
    2009 34TH IEEE PHOTOVOLTAIC SPECIALISTS CONFERENCE, VOLS 1-3, 2009, : 268 - 270
  • [28] Measurement Accuracy and Evaluation of Uncertainty Principle
    Yang, Jiudong
    INTERNATIONAL JOINT CONFERENCE ON COMPUTATIONAL SCIENCES AND OPTIMIZATION, VOL 2, PROCEEDINGS, 2009, : 172 - 175
  • [29] GENERAL APPROACH TO EVALUATION OF MEASUREMENT ACCURACY
    TSVETKOV, EI
    MEASUREMENT TECHNIQUES, 1977, 20 (12) : 1684 - 1688
  • [30] Accuracy and error analysis of optical liquid film thickness measurement with total internal reflection method (TIRM)
    Grasso, Matteo
    Petrov, Victor
    Manera, Annalisa
    EXPERIMENTS IN FLUIDS, 2024, 65 (06)