Characterization of micromachined hollow tips for two-dimensional nanoelectrospray mass spectrometry

被引:33
|
作者
Sjödahl, J
Melin, J
Griss, P
Emmer, Å
Stemme, G
Roeraade, J [1 ]
机构
[1] Royal Inst Technol, Dept Analyt Chem, S-10044 Stockholm, Sweden
[2] Royal Inst Technol, Dept Signals Sensors & Syst, S-10044 Stockholm, Sweden
关键词
D O I
10.1002/rcm.920
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work an improved design of chip-based nanoelectrospray nozzles is reported. Two-dimensional matrices of out-of-plane 10 mum i.d. silicon dioxide tips with a tapered shape were manufactured using deep reactive ion etching technology. Using a peptide sample, six micromachined tips and six commercially pulled silica capillary tips were compared employing an ion trap mass spectrometer. At a flow rate of 100 nL/min, the detectability obtained was approximately the same for the two types of tips. The relative standard deviation of the signal-to-noise ratio for the peptides between six different tips was on average 22% for the micromachined tips and 45% for the pulled capillary tips. The usefulness of the micromachined tips for analysis of non-covalent protein-ligand complexes was demonstrated by the analysis of a sample of RNase A and cytidine 2'-monophosphate. In another test, analyzing a tryptic digest of 1 pmol/muL cytochrome C, 18 peptides corresponding to a 82% sequence coverage were detected. Using MS/MS, the whole sequence of an 11 amino acid cytochrome C fragment was obtained. Computer simulations were performed on the shape and magnitude of the electrical field around micromachined and pulled capillary tips. To reach the threshold electric field density at the tip apex required to initiate an electrospray, a higher electrospray voltage was needed for the chip-based tips compared with pulled capillary tips. This is due to the influence of the chip base. Copyright (C) 2003 John Wiley Sons, Ltd.
引用
收藏
页码:337 / 341
页数:5
相关论文
共 50 条
  • [41] Two-Dimensional Tandem Mass Spectrometry for Biopolymer Structural Analysis
    Le, MyPhuong T.
    Holden, Dylan T.
    Manheim, Jeremy M.
    Dziekonski, Eric T.
    Iyer, Kiran
    Cooks, R. Graham
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2024, 63 (09)
  • [42] Comprehensive two-dimensional liquid chromatography coupled with mass spectrometry
    Pol, Jaroslav
    Hyotylainen, Tuulia
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (01) : 21 - 31
  • [43] Mass spectrometry compatibility of two-dimensional gel protein stains
    Lauber, WM
    Carroll, JA
    Dufield, DR
    Kiesel, JR
    Radabaugh, MR
    Malone, JP
    ELECTROPHORESIS, 2001, 22 (05) : 906 - 918
  • [44] Two-dimensional gel electrophoresis and mass spectrometry for biomarker discovery
    Penque, Deborah
    PROTEOMICS CLINICAL APPLICATIONS, 2009, 3 (02) : 155 - 172
  • [45] Nanoelectrospray ion generation for high-throughput mass spectrometry using a micromachined ultrasonic ejector array
    Aderogba, S
    Meacham, JM
    Degertekin, FL
    Fedorov, AG
    Fernandez, FM
    APPLIED PHYSICS LETTERS, 2005, 86 (20) : 1 - 3
  • [46] Two-dimensional liquid chromatography/mass spectrometry/mass spectrometry separation of water-soluble metabolites
    Fairchild, Jacob N.
    Horvath, Krisztian
    Gooding, Jessica R.
    Campagna, Shawn R.
    Guiochon, Georges
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (52) : 8161 - 8166
  • [47] Characterization of Phospholipids by Two-Dimensional Liquid Chromatography Coupled to In-line Ozonolysis-Mass Spectrometry
    Sun, Chenxing
    Zhao, Yuan-Yuan
    Curtis, Jonathan M.
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2015, 63 (05) : 1442 - 1451
  • [48] The proteomic characterization of ram sperm during cryopreservation analyzed by the two-dimensional electrophoresis coupled with mass spectrometry
    Lv, Chunrong
    Larbi, Allai
    Memon, Sameeullah
    Liang, Jiachong
    Zhao, Xueming
    Shao, Qingyong
    Wu, Guoquan
    Quan, Guobo
    CRYOBIOLOGY, 2020, 97 : 37 - 45
  • [49] Characterization of intact hemoglobin and oxaliplatin interaction by nanoelectrospray ionization tandem mass spectrometry
    Peng, J
    Mandal, R
    Sawyer, M
    Li, XF
    CLINICAL CHEMISTRY, 2005, 51 (12) : 2274 - 2281
  • [50] Comprehensive two-dimensional gas chromatography-mass spectrometry: A review
    Mondello, Luigi
    Tranchida, Peter Quinto
    Dugo, Paola
    Dugo, Giovanni
    MASS SPECTROMETRY REVIEWS, 2008, 27 (02) : 101 - 124