Pathology of damaging electrical stimulation in the retina

被引:48
|
作者
Colodetti, L. [1 ]
Weiland, J. D. [1 ]
Colodetti, S. [1 ]
Ray, A. [1 ]
Seiler, M. J. [1 ]
Hinton, D. R. [1 ]
Humayun, M. S. [1 ]
机构
[1] Univ So Calif, Dept Ophthalmol, Los Angeles, CA 90033 USA
关键词
retinal prosthesis; electrical stimulation; retina; retinal degeneration;
D O I
10.1016/j.exer.2007.02.014
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The goal of this study was to examine the characteristics of electrically induced retinal damage. A retinal prosthesis must be both effective and safe, but most research related to electrical stimulation of the retina has involved measures of efficacy (for example, stimulus threshold), while relatively little research has investigated the safety of electrical stimulation. In this study, a single platinum microelectrode was inserted into the vitreous cavity of normally-sighted adult Long Evans pigmented rats. In one group of animals, no contact was made between the electrode and he retina and current pulses of 0.05 (n = 3) and 0.2 (n = 6) mu C/phase were applied. In a second group, visible contact (slight dimpling of the retina) was made between the electrode and the retina and current pulses of 0.09 (n - 4) mu C/phase were applied. In both cases, stimulus pulses (biphasic, cathodic first, 1 ms/phase) were applied for 1 h at 100 Hz. Also, control experiments were run with no electrical stimulation with retina contact (n = 4) and with no retinal contact (n = 3). After stimulation, the animal was survived for 2 weeks with ocular photography and electroretinography (ERG) to document changes. During the follow-up period, retinal changes were observed only when the electrode contacted the retina, with or without electrical stimulation. No difference was noted in ERG amplitude or latency comparing the test eye to the stimulated eye. Histological analysis was performed after sacrifice at 2 weeks. A semi-quantitative method for grading 18 features of retina/RPE/choroidal appearance was established and integer grades applied to both test and control eyes. Using this method and comparing the most severely affected area (highest grade), significant differences (p < 0.05) were noted between experiments with retinal contact and without retinal contact in all features except inner nuclear layer thickness. No difference was noted within a group based on the intensity of electrical;stimulus applied. The size of the affected area was significantly larger with both retinal contact and electrical stimulation compared to with retinal contact alone. We conclude that mechanical pressure alone and mechanical pressure with excessive electrical stimulation causes damage to the retina but that electrical stimulation coupled with mechanical pressure increases the area of the damage. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:23 / 33
页数:11
相关论文
共 50 条
  • [41] Information theoretical approach for optimizing electrical stimulation of cat retina by a retina implant.
    Eger, M
    Schanze, T
    Wilms, M
    Eckhorn, R
    EUROPEAN JOURNAL OF NEUROSCIENCE, 1998, 10 : 431 - 431
  • [42] ELECTRICAL STIMULATION OF ON- AND OFF-UNITS IN CATS RETINA
    TAIRA, N
    IMAZAWA, Y
    MOTOKAWA, K
    TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 1965, 85 (01): : 89 - 104
  • [43] Electrical stimulation therapy for retina investigated in a rat model of adRP
    Rahmani, S
    Hetling, JR
    Bogdanowicz, LB
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [44] Visual perception elicited by electrical stimulation of retina in blind humans
    Humayun, MS
    deJuan, E
    Dagnelie, G
    Greenberg, RJ
    Prost, RH
    Phillips, DH
    ARCHIVES OF OPHTHALMOLOGY, 1996, 114 (01) : 40 - 46
  • [45] Dynamic response of the human retina to pulsed optical and electrical stimulation
    Akchurin, GG
    Bakutkin, VV
    Kamenskih, TG
    Zemskova, TM
    Ahuja, P
    SARTOV FALL MEETING '99: OPTICAL TECHNOLOGIES IN BIOPHYSICS AND MEDICINE, 2000, 4001 : 402 - 405
  • [46] Electrical stimulation of the retina in normal and retinal degenerate dog.
    Weiland, JD
    Shyu, JS
    Margalit, E
    Chen, SJ
    D'Anna, SA
    Suzuki, S
    Humayun, MS
    de Juan, E
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S888 - S888
  • [47] Responses to electrical stimulation of the degenerate retina measured at the cornea in rats
    Hetling, JR
    Baig-Silva, MS
    Hathcock, CD
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [48] Optimization of Electrical Stimulation for a High-Fidelity Artificial Retina
    Shah, Nishal P.
    Madugula, Sasidhar
    Grosberg, Lauren
    Mena, Gonzalo
    Tandon, Pulkit
    Hottowy, Pawel
    Sher, Alexander
    Litke, Alan
    Mitra, Subhasish
    Chichilnisky, E. J.
    2019 9TH INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING (NER), 2019, : 714 - 718
  • [49] Visual cortical potentials of the mouse evoked by electrical stimulation of the retina
    Siu, Timothy L.
    Morley, John W.
    BRAIN RESEARCH BULLETIN, 2008, 75 (01) : 115 - 118
  • [50] SUPERIOR COLLICULUS CELL RESPONSES TO ELECTRICAL-STIMULATION OF RETINA
    MOLOTCHNIKOFF, S
    LARCHEVEQUE, PL