Continuously Moving Table Time-of-Flight Angiography of the Peripheral Veins

被引:2
|
作者
Huff, Sandra [1 ]
Honal, Matthias [1 ]
Baumann, Tobias [1 ]
Hennig, Juergen [1 ]
Markl, Michael [1 ]
Ludwig, Ute [1 ]
机构
[1] Univ Hosp Freiburg, Dept Diagnost Radiol, D-79106 Freiburg, Germany
关键词
moving table MRI; extended FOV; peripheral MR angiography; time-of-flight MR angiography; venous diseases; ENHANCED MR-ANGIOGRAPHY; DIGITAL-SUBTRACTION-ANGIOGRAPHY; MAGNETIC-RESONANCE ANGIOGRAPHY; NEPHROGENIC SYSTEMIC FIBROSIS; DEEP VENOUS THROMBOSIS; LOWER-EXTREMITY; INITIAL-EXPERIENCE; CONTRAST; ACQUISITIONS; VIEW;
D O I
10.1002/mrm.22296
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Time-of-flight (TOF) MR angiography allows for noninvasive vessel imaging. To overcome the limited volumetric coverage of standard TOF techniques, the aim of this study was to investigate the combination of TOF and continuously moving table (CMT) acquisitions for peripheral vein imaging based on image subtraction. Two acquisition strategies are presented: a simple two-step method based on 2-fold CMT acquisition and an advanced one-step method requiring only one continuous scan. Image quality of both CMT TOF techniques was evaluated by semiquantitative image grading and by signal-to-noise ratio and contrast-to-noise ratio analysis for veins of the upper and lower leg in 10 healthy volunteers. Results were compared to a standard stationary two-dimensional (2D) TOF multistation acquisition. Image grading revealed good image quality for both CMT TOF methods, thereby confirming the feasibility of axial 2D CMT TOF to assess the veins of the lower extremities during a single scan. Quantitative evaluation showed no significant difference in signal-to-noise ratio and contrast-to-noise ratio compared to the stationary experiment. Additional measurements in three patients with post-thrombotic changes and varicosities demonstrated the clinical applicability of the presented methods. CMT TOF provides promising results and permits the detection of various pathologic changes of the venous system. Magn Reson Med 63:1219-1229, 2010. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:1219 / 1229
页数:11
相关论文
共 50 条
  • [41] Glioma vessel abnormality quantification using time-of-flight MR angiography
    Maddalena Strumia
    Wilfried Reichardt
    Ori Staszewski
    Dieter Henrik Heiland
    Astrid Weyerbrock
    Irina Mader
    Michael Bock
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2016, 29 : 765 - 775
  • [42] Pseudorandom time-of-flight analysis with a time-of-flight mass spectrometer
    Bewig, L
    Buck, U
    Gandhi, SR
    Winter, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (02): : 417 - 422
  • [43] Towards Generalised Time-of-Flight Range Imaging at the Edge of Moving Objects
    Streeter, Lee
    2017 INTERNATIONAL CONFERENCE ON IMAGE AND VISION COMPUTING NEW ZEALAND (IVCNZ), 2017,
  • [44] Detection and classification of moving objects-stereo or Time-oF-Flight images
    Ghobadi, Seyed Eghbal
    Hartmann, Klaus
    Weihs, Wolfgang
    Netramai, Chayakorn
    Loffeld, Otmar
    Roth, Hubert
    2006 INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE AND SECURITY, PTS 1 AND 2, PROCEEDINGS, 2006, : 11 - 16
  • [45] Desorption/ionization on silicon time-of-flight/time-of-flight mass spectrometry
    Go, EP
    Prenni, JE
    Wei, J
    Jones, A
    Hall, SC
    Witkowska, HE
    Shen, ZX
    Siuzdak, G
    ANALYTICAL CHEMISTRY, 2003, 75 (10) : 2504 - 2506
  • [46] Design of a table-top time-of-flight Mass Spectrometer with high resolution
    Denshi Gijutsu Sogo Kenkyusho Iho, 11 (1-9):
  • [47] Increased Resolution of Time-of-Flight MR Angiography at Higher Field Strength Response
    Shi, Zhang
    Zhao, Xueying
    Zeng, Mengsu
    Wang, He
    RADIOLOGY, 2023, 307 (04)
  • [48] MOYAMOYA DISEASE - DIAGNOSIS WITH 3-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY
    YAMADA, I
    MATSUSHIMA, Y
    SUZUKI, S
    RADIOLOGY, 1992, 184 (03) : 773 - 778
  • [49] Postcontrast time-of-flight MR angiography demonstrating collateral flow in acute stroke
    Sohn, Chul-Ho
    Sohn, Sung-Il
    Chang, Hyuk-Won
    Demchuk, Andrew M.
    STROKE, 2007, 38 (04) : 1132 - 1133
  • [50] Time-of-flight MR angiography of different patterns of internal carotid artery dissection
    Brunereau, L
    Levy, C
    Djouhri, H
    MarsotDupuch, K
    Bousser, MG
    Tubiana, J
    RADIOLOGY, 1996, 201 : 107 - 107