Objectives: This study investigated the influence of resin composite preheating temperature, light curing regimen (mode and duration) on post-gel shrinkage strain (PGSS) and degree of conversion (DC) of a restorative resin composite. Methods: A hybrid resin composite preheated to three different temperatures (37 degrees C, 54 degrees C and 68 degrees C) was cured using a high intensity light emitting diode (LED) curing unit. The light source was used in 40- and 20-second continuous mode as well as soft start mode. The resin composite was monitored for PGSS during curing and 10 minutes following light irradiation using strain gauges. DC was measured using FTIR spectrometer. The results were analyzed using two-way ANOVA followed by the Duncan's Multiple Range Test for pairwise comparisons. The significance level was set at p <= 0.05. Results: Preheating of the resin composite significantly increased its PGSS and DC. The soft start groups revealed significantly lower PGSS values compared to the 20- and 40-second groups without altering the DC. Conclusions: Preheating of resin composite prior to curing increased its DC but also increased its PGSS. The soft-start mode decreased the PGSS of resin composite without altering the DC.
机构:
Tsinghua Univ, State Key Lab New Ceram & Fine Proc, Beijing 100084, Peoples R ChinaTsinghua Univ, State Key Lab New Ceram & Fine Proc, Beijing 100084, Peoples R China
Tong Shuyan
Wu Yin
论文数: 0引用数: 0
h-index: 0
机构:
Tsinghua Univ, State Key Lab New Ceram & Fine Proc, Beijing 100084, Peoples R ChinaTsinghua Univ, State Key Lab New Ceram & Fine Proc, Beijing 100084, Peoples R China
Wu Yin
Si Wenjie
论文数: 0引用数: 0
h-index: 0
机构:
Tsinghua Univ, State Key Lab New Ceram & Fine Proc, Beijing 100084, Peoples R ChinaTsinghua Univ, State Key Lab New Ceram & Fine Proc, Beijing 100084, Peoples R China
机构:
Imam Abdulrahman Bin Faisal Univ, Coll Dent, Dept Restorat Dent Sci, Dammam, Saudi ArabiaImam Abdulrahman Bin Faisal Univ, Coll Dent, Dept Restorat Dent Sci, Dammam, Saudi Arabia
Khabeer, Abdul
Ahmed, Syed Z.
论文数: 0引用数: 0
h-index: 0
机构:
Imam Abdulrahman Bin Faisal Univ, Coll Dent, Dept Restorat Dent Sci, Dammam, Saudi ArabiaImam Abdulrahman Bin Faisal Univ, Coll Dent, Dept Restorat Dent Sci, Dammam, Saudi Arabia
Ahmed, Syed Z.
Zubair, Mukarram
论文数: 0引用数: 0
h-index: 0
机构:
Imam Abdulrahman Bin Faisal Univ, Coll Engn, Dept Environm Engn, Dammam, Saudi ArabiaImam Abdulrahman Bin Faisal Univ, Coll Dent, Dept Restorat Dent Sci, Dammam, Saudi Arabia
Zubair, Mukarram
Faridi, Muhammad A.
论文数: 0引用数: 0
h-index: 0
机构:
Imam Abdulrahman Bin Faisal Univ, Coll Dent, Dept Restorat Dent Sci, Dammam, Saudi ArabiaImam Abdulrahman Bin Faisal Univ, Coll Dent, Dept Restorat Dent Sci, Dammam, Saudi Arabia
Faridi, Muhammad A.
Al-Harthi, Mamdouh A.
论文数: 0引用数: 0
h-index: 0
机构:
King Fahd Univ Petr & Minerals, Dept Chem Engn, Dhahran, Saudi Arabia
King Fahd Univ Petr & Minerals, Ctr Res Excellence Nanotechnol, Dhahran, Saudi ArabiaImam Abdulrahman Bin Faisal Univ, Coll Dent, Dept Restorat Dent Sci, Dammam, Saudi Arabia