Quantitative analysis of residual synthetic polystyrene adsorbent in drugs by Curie-point pyrolysis gas chromatography

被引:1
|
作者
Muguruma, S
Uchino, S
Oguri, N
Kiji, J
机构
[1] Japan Analyt Ind Co Ltd, Osaka Lab, Yodogawa Ku, Osaka 532, Japan
[2] Japan Analyt Ind Co Ltd, Lab, Mizuho Ku, Tokyo 19012, Japan
[3] Tottori Univ, Dept Mat Sci, Tottori 680, Japan
关键词
gas chromatography; pyrolysis GC; residual polystyrene; streptomycin; vitamin B-1;
D O I
10.1007/BF02466582
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Residual synthetic adsorbent, cross-linked polystyrene, used in drug purification has been analyzed quantitatively by Curie-point pyrolysis gas chromatography. The peaks of intact polystyrene adsorbent in the pyrogram were used as key peaks for quantitative measurement of residues of the adsorbent in vitamin B-1 and streptomycin sulfate. It was shown that the m-ethylstyrene or p-ethylstyrene peaks in the pyrolyzates were suitable for determination of polystyrene adsorbent content. The levels of residual adsorbent in the drugs were found to be < 0.1 %, the value stipulated by the International Conference on Harmonization (ICH). In quantitative evaluation of an adsorbent content of 0.1 % the precision was 3.6 % and 2.7 % for vitamin B-1 and streptomycin sulfate, respectively.