Quantitative analysis of residual synthetic polystyrene adsorbent in drugs by Curie-point pyrolysis gas chromatography

被引:1
|
作者
Muguruma, S
Uchino, S
Oguri, N
Kiji, J
机构
[1] Japan Analyt Ind Co Ltd, Osaka Lab, Yodogawa Ku, Osaka 532, Japan
[2] Japan Analyt Ind Co Ltd, Lab, Mizuho Ku, Tokyo 19012, Japan
[3] Tottori Univ, Dept Mat Sci, Tottori 680, Japan
关键词
gas chromatography; pyrolysis GC; residual polystyrene; streptomycin; vitamin B-1;
D O I
10.1007/BF02466582
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Residual synthetic adsorbent, cross-linked polystyrene, used in drug purification has been analyzed quantitatively by Curie-point pyrolysis gas chromatography. The peaks of intact polystyrene adsorbent in the pyrogram were used as key peaks for quantitative measurement of residues of the adsorbent in vitamin B-1 and streptomycin sulfate. It was shown that the m-ethylstyrene or p-ethylstyrene peaks in the pyrolyzates were suitable for determination of polystyrene adsorbent content. The levels of residual adsorbent in the drugs were found to be < 0.1 %, the value stipulated by the International Conference on Harmonization (ICH). In quantitative evaluation of an adsorbent content of 0.1 % the precision was 3.6 % and 2.7 % for vitamin B-1 and streptomycin sulfate, respectively.
引用
收藏
页码:203 / 208
页数:6
相关论文
共 50 条
  • [1] Quantitative analysis of residual synthetic polystyrene adsorbent in drugs by curie-point pyrolysis gas chromatography
    S. Muguruma
    S. Uchino
    N. Oguri
    J. Kiji
    Chromatographia, 1998, 47 : 203 - 208
  • [2] Application of the Curie-point pyrolysis high resolution gas chromatography for analysis of synthetic polymers and copolymers
    Kusch, P
    CHEMIA ANALITYCZNA, 1996, 41 (02): : 241 - 252
  • [3] CURIE-POINT PYROLYSIS, GAS-LIQUID-CHROMATOGRAPHY OF XYLAN
    OHNISHI, A
    TAKAGI, E
    KATO, K
    CARBOHYDRATE RESEARCH, 1976, 50 (02) : 275 - 278
  • [4] THE CHARACTERIZATION OF 8 MACERAL CONCENTRATES BY MEANS OF CURIE-POINT PYROLYSIS-GAS CHROMATOGRAPHY AND CURIE-POINT PYROLYSIS-GAS CHROMATOGRAPHY-MASS SPECTROMETRY
    NIP, M
    DELEEUW, JW
    SCHENCK, PA
    GEOCHIMICA ET COSMOCHIMICA ACTA, 1988, 52 (03) : 637 - 648
  • [5] MULTICHANNEL AUTOSAMPLER FOR CURIE-POINT PYROLYSIS CAPILLARY GAS-CHROMATOGRAPHY
    OGURI, N
    ONISHI, A
    HANAI, T
    JIN, XG
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1992, 15 (01): : 9 - 12
  • [6] FULLY AUTOMATED CURIE-POINT PYROLYSIS GAS-LIQUID-CHROMATOGRAPHY
    MEUZELAAR, HLC
    FICKE, HG
    DENHARINK, HC
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1975, 13 (01) : 12 - 17
  • [7] CURIE-POINT PYROLYSIS IN THE ANALYSIS OF PLASTICS
    FISCHER, WG
    KUSCH, P
    KUNSTSTOFFE-GERMAN PLASTICS, 1992, 82 (05): : 405 - 407
  • [8] AUTOMATIC CURIE-POINT PYROLYSIS-GAS CHROMATOGRAPHY WITH CAPILLARY COLUMNS FOR THE ANALYSIS OF RUBBER MIXTURES
    SCHRAFFT, R
    KAUTSCHUK GUMMI KUNSTSTOFFE, 1983, 36 (10): : 851 - 858
  • [9] NEW AUTOMATIC SAMPLER FOR CURIE-POINT PYROLYSIS IN COMBINATION WITH GAS-CHROMATOGRAPHY
    SCHULTEN, HR
    FISCHER, WG
    WALLSTAB, HJ
    JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1987, 10 (08): : 467 - 469
  • [10] Automatic Curie-Point Pyrolysis Gas Chromatography with Capillary Columns for the Analysis of Rubber Mixtures.
    Schrafft, R.
    Kautschuk und Gummi, Kunststoffe, 1983, 36 (10): : 851 - 858