Assessment of air quality in Paris by personal monitoring of nonsmokers for respirable suspended particles and environmental tobacco smoke

被引:20
|
作者
Phillips, K [1 ]
Bentley, MC
Howard, DA
Alvan, G
机构
[1] Covance Labs Ltd, Dept Air Qual Monitoring, Harrogate, England
[2] Huddinge Univ Hosp, Karolinska Inst, Dept Med Lab Sci & Technol, Div Clin Pharmacol, S-14186 Huddinge, Sweden
关键词
D O I
10.1016/S0160-4120(98)00020-8
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Exposure to respirable suspended particles (RSP), environmental tobacco smoke (ETS) particles, nicotine, and 3-ethenylpyridine (3-EP) was assessed in Paris for 222 subjects during March and April 1995. Personal monitors were worn over a 24-h period, each subject providing a saliva sample for cotinine analysis both prior to and following the monitoring period. Comprehensive lifestyle questionnaires were also completed before and after the monitoring period. The study comprised housewives in one group, primarily for assessing exposures in the home, and office workers in a second group to assess exposures in the workplace. A single personal monitor was worn by each housewife, while employed subjects wore one monitor at work and a separate monitor at home and elsewhere. Based on median 24-h time-weighted average exposures, the most highly exposed subjects to RSP, ETS particles, nicotine, and 3-EP were office workers living with smokers. Additionally, based upon nicotine exposures, subjects who were also employed in locations where smoking was allowed were the most exposed. Based upon median levels, housewives living in nonsmoking households would be exposed to 1 cigarette equivalent per y or less, compared with between 1.2 and 3 cigarette equivalents per y for housewives living in smoking households. Subjects living and working with smokers had the highest median saliva cotinine level of 1.6 ng mL(-1). Using a cut off level of 25 ng mL(-1) to indicate active smoking, up to 4.7% of the subjects were found to have misreported themselves as nonsmokers. (C) 1998 Elsevier Science Ltd.
引用
收藏
页码:405 / 425
页数:21
相关论文
共 50 条
  • [21] A PERSONAL MONITORING STUDY TO ASSESS WORKPLACE EXPOSURE TO ENVIRONMENTAL TOBACCO-SMOKE
    COULTAS, DB
    SAMET, JM
    MCCARTHY, JF
    SPENGLER, JD
    [J]. AMERICAN JOURNAL OF PUBLIC HEALTH, 1990, 80 (08) : 988 - 990
  • [22] Environmental tobacco smoke in an unrestricted smoking workplace: area and personal exposure monitoring
    Jenkins, RA
    Maskarinec, MP
    Counts, RW
    Caton, JE
    Tomkins, BA
    Ilgner, RH
    [J]. JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY, 2001, 11 (05): : 369 - 380
  • [23] Environmental tobacco smoke in an unrestricted smoking workplace: area and personal exposure monitoring
    ROGER A JENKINS
    MICHAEL P MASKARINEC
    RICHARD W COUNTS
    JOHN E CATON
    BRUCE TOMKINS
    RALPH H ILGNER
    [J]. Journal of Exposure Science & Environmental Epidemiology, 2001, 11 : 369 - 380
  • [24] ENVIRONMENTAL TOBACCO-SMOKE IN THE CONTEXT OF INDOOR AIR-QUALITY
    BROWN, RC
    [J]. HUMAN TOXICOLOGY, 1989, 8 (01): : 3 - 4
  • [25] Tobacco smoke particles and indoor air quality (ToPIQ) - the protocol of a new study
    Daniel Mueller
    Stefanie Uibel
    Markus Braun
    Doris Klingelhoefer
    Masaya Takemura
    David A Groneberg
    [J]. Journal of Occupational Medicine and Toxicology, 6
  • [26] Tobacco smoke particles and indoor air quality (ToPIQ) - the protocol of a new study
    Mueller, Daniel
    Uibel, Stefanie
    Braun, Markus
    Klingelhoefer, Doris
    Takemura, Masaya
    Groneberg, David A.
    [J]. JOURNAL OF OCCUPATIONAL MEDICINE AND TOXICOLOGY, 2011, 6
  • [27] IMPACT OF ENVIRONMENTAL TOBACCO-SMOKE ON AIRLINE CABIN AIR-QUALITY
    HOLCOMB, LC
    [J]. ENVIRONMENTAL TECHNOLOGY LETTERS, 1988, 9 (06): : 509 - 514
  • [28] INDOOR AIR-QUALITY AND ENVIRONMENTAL TOBACCO-SMOKE - CONCENTRATION AND EXPOSURE
    HOLCOMB, LC
    [J]. ENVIRONMENT INTERNATIONAL, 1993, 19 (01) : 9 - 40
  • [29] ENVIRONMENTAL TOBACCO-SMOKE AND INDOOR AIR-QUALITY - A PROBLEM REVISITED
    MCCUNNEY, RJ
    CASHINS, R
    [J]. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1988, 30 (07) : 540 - &
  • [30] Performance evaluation of simultaneous monitoring of personal exposure to environmental tobacco smoke and volatile organic compounds
    Baek, SO
    Jenkins, RA
    [J]. INDOOR AND BUILT ENVIRONMENT, 2001, 10 (3-4) : 200 - 208