Steel beam-to-column connections equipped with SMA tendons and energy dissipating devices including shear tabs or web hourglass pins

被引:37
|
作者
Farmani, Mohammad Amin [1 ]
Ghassemieh, Mehdi [1 ]
机构
[1] Univ Tehran, Coll Engn, Sch Civil Engn, Tehran, Iran
关键词
Shape memory alloy (SMA); Beam column connection; Recentering; Cyclic loading; Energy dissipation; SHAPE-MEMORY ALLOY; SEISMIC PERFORMANCE ASSESSMENT; CYCLIC BEHAVIOR; FRAMES; FEASIBILITY;
D O I
10.1016/j.jcsr.2017.04.003
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents a numerical study on two innovative classes of beam-to-column connections equipped with superelastic shape memory alloy (SMA) tendons as recentering elements and shear tabs or web hourglass steel pins (WHPs) as supplementary energy dissipating and shear resisting components. First, the finite element model of the shear tab connection with SMA tendons is produced and analyzed to validate the numerical analysis against the prior experimental results. Then, special cast high strength brackets are proposed to incorporate SMA tendons in the connections. Afterwards, a parametric study is performed considering the effects of shear tabs' presence, SMA tendons' initial prestress, shear tab bolts' initial prestress, coefficient of friction between shear tab and beam web, length/arrangement of SMA tendons and brackets, and shear resisting mechanism of the connection. Finally, additional class of SMA-based connections equipped with hourglass steel pins passing through the beam web is introduced, studied under cyclic loads, and examined when subjected to high levels of shear force demand. Results show that incorporating shear tabs and WHPs in the SMA-based connections, if properly designed and installed, not only improves their energy dissipation capability, but also can enhance their moment capacity, initial stiffness, and shear resistance, with no negative effect on the recentering ability.
引用
收藏
页码:30 / 48
页数:19
相关论文
共 45 条
  • [41] Restoring force model of precast concrete-filled steel tube column-to-RC beam connections with energy-dissipating bolts
    Zhang Y.
    Li D.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2023, 44 (04): : 309 - 318
  • [42] Structural behaviour of steel-timber composite (STC) beam-to-column connections with double angle web cleats subjected to hogging bending moment
    Nouri, F.
    Valipour, H. R.
    Bradford, M. A.
    ENGINEERING STRUCTURES, 2019, 192 : 1 - 17
  • [43] Quasi-static cyclic testing and analytical investigation of steel plate shear walls with different post-tensioned beam-to-column rocking connections
    Dowden, Daniel M.
    Bruneau, Michel
    ENGINEERING STRUCTURES, 2019, 187 : 43 - 56
  • [44] Experimental study on spatial prefabricated self-centering steel frame with beam-column connections containing bolted web friction devices
    Zhang, Yanxia
    Li, Quangang
    Yan Zhuge
    Liu, Anran
    Zhao, Wenzhan
    ENGINEERING STRUCTURES, 2019, 195 : 1 - 21
  • [45] The Research of Test on Steel Frame Beam-column Connections with Rib Top and Seat Angle and Angle with Two Web Node Energy Consumption
    Liu, Wei
    Wang, Guang-yun
    Zhang, Xiong
    Yu, Hai-tao
    ADVANCES IN CIVIL STRUCTURES, PTS 1 AND 2, 2013, 351-352 : 483 - 486