Clinical efficacy of an ultrasound contrast agent with harmonic imaging in the post-operative evaluation of aortic aneurysm repair

被引:0
|
作者
Bendick, PJ [1 ]
机构
[1] William Beaumont Hosp, Peripheral Vasc Diagnost Ctr, Royal Oak, MI 48072 USA
关键词
ultrasound contrast; harmonics; aortic stent grafts;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
We have evaluated the efficacy of duplex ultrasound (US) harmonic imaging with the addition of an ultrasound contrast agent in the post-operative evaluation of aortic aneurysm repair. Duplex ultrasound evaluation was done with the contrast was circulating throughout the blood pool, using digitally coded transmit-receive ultrasound pulse sequences with tissue harmonic imaging to optimize visualization. Twenty patients were evaluated, eighteen with modular stent grafts and two with unibody bifurcated stent grafts. All stent grafts remained widely patent with normal aorto-iliac flow hemodynamics. Duplex ultrasound with contrast identified all eight of the endoleaks seen by computed tomography anglography. In two patients ultrasound with contrast detected small endoleaks not seen by CTA, but confirmed by angiography at the time of endovascular closure. Standard duplex ultrasound failed to identify four of the ten endoleaks. Duplex ultrasound, when used with an ultrasound contrast agent in the follow-up of aortic aneurysm repair, appears to provide very good sensitivity to patency and the presence and type of any endoleaks present.
引用
收藏
页码:949 / 950
页数:2
相关论文
共 50 条
  • [31] Contrast harmonic imaging ultrasound and perfusion imaging for surveillance after endovascular abdominal aneurysm repair regarding detection and characterization of suspected endoleaks
    Pfister, K.
    Rennert, J.
    Uller, W.
    Schnitzbauer, A. A.
    Stehr, A.
    Jung, W.
    Hofstetter, P.
    Zorger, N.
    Kasprzak, P. M.
    Jung, E. M.
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2009, 43 (1-2) : 119 - 128
  • [32] Post-operative echo evaluation in chitra valves in mitral and aortic position
    C Raghavendra
    UE Jadhav
    R Parida
    S Kumar
    Ahuja Vinod
    A Agrawal
    N Rao
    AG Tendolkar
    Indian Journal of Thoracic and Cardiovascular Surgery, 2006, 22 (1) : 54 - 54
  • [33] POST-OPERATIVE ALTERATIONS IN SIZE OF DACRON AORTIC GRAFTS - ULTRASONIC EVALUATION
    NUNN, DB
    FREEMAN, MH
    HUDGINS, PC
    ANNALS OF SURGERY, 1979, 189 (06) : 741 - 745
  • [34] Clinical evaluation of a new oral ultrasound contrast agent
    Thomas Jefferson Univ, Philadelphia, United States
    Ultrasound Med Biol, 1600, Suppl 1 (IMO 1607):
  • [35] Safety and Accuracy of Endovascular Aneurysm Repair Without Pre-operative and Intra-operative Contrast Agent
    Kaladji, A.
    Dumenil, A.
    Mahe, G.
    Castro, M.
    Cardon, A.
    Lucas, A.
    Haigron, P.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2015, 49 (03) : 255 - 261
  • [36] Evaluation of myocardial, hepatic, and renal perfusion in a variety of clinical conditions using an intravenous ultrasound contrast agent (Optison) and second harmonic imaging
    Hancock, J
    Dittrich, H
    Jewitt, DE
    Monaghan, MJ
    HEART, 1999, 81 (06) : 636 - 641
  • [37] Post-operative radiosurgery for brain metastases: clinical and dosimetric evaluation
    Pinzi, V.
    Romeo, A.
    Marchetti, M.
    Morlino, S.
    Fariselli, L.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S57 - S57
  • [38] Results of a prospective observational cohort study investigating the incidence of post-operative cognitive decline following elective endovascular aortic aneurysm repair
    Benson, R. A.
    BRITISH JOURNAL OF SURGERY, 2017, 104 : 13 - 14
  • [39] Contrast-enhanced MR imaging for evaluation of coronary artery disease before elective repair of aortic aneurysm
    Ishida, M
    Sakuma, H
    Kato, N
    Ishida, N
    Kitagawa, K
    Shimono, T
    Yada, I
    Takeda, K
    RADIOLOGY, 2005, 237 (02) : 458 - 464
  • [40] Visualization of perfusion imaging using ultrasound contrast agent and harmonic ultrasound in rabbit eyes.
    Hirokawa, T
    Hayashi, M
    Murata, H
    Takebayashi, M
    Fuke, K
    Ohki, T
    Kajima, M
    Naito, T
    Yamane, S
    Shiota, H
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S415 - S415