Clinical efficacy of an ultrasound contrast agent with harmonic imaging in the post-operative evaluation of aortic aneurysm repair

被引:0
|
作者
Bendick, PJ [1 ]
机构
[1] William Beaumont Hosp, Peripheral Vasc Diagnost Ctr, Royal Oak, MI 48072 USA
关键词
ultrasound contrast; harmonics; aortic stent grafts;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
We have evaluated the efficacy of duplex ultrasound (US) harmonic imaging with the addition of an ultrasound contrast agent in the post-operative evaluation of aortic aneurysm repair. Duplex ultrasound evaluation was done with the contrast was circulating throughout the blood pool, using digitally coded transmit-receive ultrasound pulse sequences with tissue harmonic imaging to optimize visualization. Twenty patients were evaluated, eighteen with modular stent grafts and two with unibody bifurcated stent grafts. All stent grafts remained widely patent with normal aorto-iliac flow hemodynamics. Duplex ultrasound with contrast identified all eight of the endoleaks seen by computed tomography anglography. In two patients ultrasound with contrast detected small endoleaks not seen by CTA, but confirmed by angiography at the time of endovascular closure. Standard duplex ultrasound failed to identify four of the ten endoleaks. Duplex ultrasound, when used with an ultrasound contrast agent in the follow-up of aortic aneurysm repair, appears to provide very good sensitivity to patency and the presence and type of any endoleaks present.
引用
收藏
页码:949 / 950
页数:2
相关论文
共 50 条
  • [1] The post-operative complications of endovascular aortic aneurysm repair
    Bown, MJ
    Fishwick, G
    Sayers, RD
    JOURNAL OF CARDIOVASCULAR SURGERY, 2004, 45 (04): : 335 - 347
  • [2] The post-operative mortality of ruptured abdominal aortic aneurysm repair
    Bown, MJ
    Cooper, NJ
    Sutton, AJ
    Prytherch, D
    Nicholson, ML
    Bell, PRF
    Sayers, RD
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2004, 27 (01) : 65 - 74
  • [3] Incidence of Contrast-Induced Nephropathy and Post-Operative Outcomes in Patients Undergoing Chimney Endovascular Aortic Aneurysm Repair
    Caradu, Caroline
    Coatsaliou, Quentin
    Colacchio, Elda Chiara
    Ducasse, Eric
    Lareyre, Fabien
    Raffort, Juliette
    ANGIOLOGY, 2022, 73 (09) : 852 - 862
  • [4] Gender Differences in Post-operative Outcomes Following Surgical Repair of Ruptured Abdominal Aortic Aneurysm
    Yunus, Rayaan
    Rehman, Taha A.
    Sohail, Ahmed
    Russ, Elizabeth
    Khan, Adnan
    Mahmood, Feroze
    Matyal, Robina
    ANESTHESIA AND ANALGESIA, 2023, 136 : 128 - 129
  • [5] ANALYSIS OF POST-OPERATIVE ABDOMINAL AORTIC ANEURYSM REPAIR: A MULTI PATIENT-SPECIFIC STUDY
    Molony, David
    Walsh, Michael
    McGloughlin, Tim
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2009, PT A AND B, 2009, : 1043 - 1044
  • [6] Continuous spinal anaesthesia/analgesia for abdominal aortic aneurysm repair and post-operative pain management
    Michaloudis, D
    Petrou, A
    Fraidakis, O
    Kafkalaki, K
    Katsamouris, A
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 1999, 16 (11) : 810 - 815
  • [7] Thoracic Endovascular Aortic Repair for the Treatment of Aortic Dissection: Post-operative Imaging, Complications and Secondary Interventions
    Ameli-Renani, Seyed
    Das, R.
    Morgan, R. A.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2015, 38 (06) : 1391 - 1404
  • [8] Thoracic Endovascular Aortic Repair for the Treatment of Aortic Dissection: Post-operative Imaging, Complications and Secondary Interventions
    Seyed Ameli-Renani
    R. Das
    R. A. Morgan
    CardioVascular and Interventional Radiology, 2015, 38 : 1391 - 1404
  • [9] Patient Reported Outcome Measures (PROM) for Abdominal Aortic Aneurysm (AAA) repair Pre-operative and Post-Operative
    Patullo, Louise
    Jaipersad, Anthony
    QUALITY OF LIFE RESEARCH, 2022, 31 (SUPPL 1) : 7 - 8
  • [10] Harmonic chirp imaging method for ultrasound contrast agent
    Borsboom, JMG
    Chin, CT
    Bouakaz, A
    Versluis, M
    de Jong, N
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2005, 52 (02) : 241 - 249