External electrical cardioversion in patients with cardiac implantable electronic devices: Is it safe and is immediate device interrogation necessary?

被引:6
|
作者
Pluymaekers, Nikki A. H. A. [1 ]
Dudink, Elton A. M. P. [1 ]
Boersma, Lucas [2 ]
Erkuner, Omer [1 ]
Gelissen, Marloes [1 ]
van Dijk, Vincent [2 ]
Wijffels, Maurits [2 ]
Trang Dinh [1 ]
Vernooy, Kevin [1 ]
Crijns, Harry J. G. M. [1 ]
Balt, Jippe [2 ]
Luermans, Justin G. L. M. [1 ]
机构
[1] MUMC, Dept Cardiol, Cardiovasc Res Inst Maastricht CARIM, Maastricht, Netherlands
[2] St Antonius Hosp, Dept Cardiol, Nieuwegein, Netherlands
来源
关键词
CIED; external ECV; immediate device interrogation; safety; ATRIAL-FIBRILLATION; EUROPEAN-SOCIETY; TASK-FORCE; PACEMAKER; DEFIBRILLATION; GUIDELINES; MANAGEMENT;
D O I
10.1111/pace.13467
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundAtrial tachyarrhythmias are common in patients with cardiac implantable electronic devices (CIEDs). Restoration of sinus rhythm by external electrical cardioversion (eECV) is frequently used to alleviate symptoms and to ensure optimal device function. ObjectivesTo evaluate the safety of eECV in patients with contemporary CIEDs and to assess the need for immediate device interrogation after eECV. MethodsWe conducted a retrospective observational study of 229 patients (27.9% female, age 6910 years) with a CIED (104 pacemakers, 69 implantable cardioverter defibrillators, and 56 biventricular devices) who underwent eECV between 2008 and 2016 in two centers. Data from device interrogation before eECV, immediately afterwards, and at first follow-up (FU) after eECV were collected. CIED-related complications and adverse events during and after eECV were recorded. ResultsNo significant differences between right atrial (RA) and right ventricular (RV) sensing or threshold values before eECV, immediately afterwards, or at FU were observed. A small yet significant decrease was observed in RA and RV impedance immediately after eECV (484 vs 462, P<0.001 and 536 vs 514, P<0.001, respectively). The RV impedance did not recover to the baseline value (538 vs 527 , P=0.02). The impedance changes were without clinical consequences. No changes in left ventricular lead threshold or impedance values were measured. No CIED-related complications or adverse events were documented following eECV. ConclusioneECV in patients with contemporary CIEDs is safe. There seems to be no need for immediate device interrogation after eECV.
引用
收藏
页码:1336 / 1340
页数:5
相关论文
共 50 条
  • [21] Postmortem Interrogation of Cardiac Implantable Electronic Devices A 15-Year Experience
    Paratz, Elizabeth D.
    Block, Tomasz J.
    Stub, Dion A.
    La Gerche, Andre
    Kistler, Peter M.
    Kalman, Jonathan M.
    Strathmore, Neil
    Mond, Harry
    Woodford, Noel W. F.
    Burke, Michael
    Voskoboinik, Aleksandr
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2022, 8 (03) : 356 - 366
  • [22] Unearthing the evidence: post-mortem interrogation of cardiac implantable electronic devices
    Block, T.
    Paratz, E.
    La Gerche, A.
    Stub, D.
    Strathmore, N.
    Mond, H.
    Kistler, P.
    Kalman, J.
    Burke, M.
    Voskoboinik, A.
    EUROPEAN HEART JOURNAL, 2021, 42 : 407 - 407
  • [23] MRI for Patients with Cardiac Implantable Electrical Devices
    Chow, Grant V.
    Nazarian, Saman
    CARDIOLOGY CLINICS, 2014, 32 (02) : 299 - +
  • [24] MRI of Patients with Cardiac Implantable Electronic Devices
    Martinez, Jessica A.
    Ennis, Daniel B.
    CURRENT CARDIOVASCULAR IMAGING REPORTS, 2019, 12 (07)
  • [25] MRI in patients with cardiac implantable electronic devices
    Cronin, Edmond M.
    Mahon, Niall
    Wilkoff, Bruce L.
    EXPERT REVIEW OF MEDICAL DEVICES, 2012, 9 (02) : 139 - 146
  • [26] MRI in Patients with Cardiac Implantable Electronic Devices
    Muthalaly, Rahul G.
    Nerlekar, Nitesh
    Ge, Yin
    Kwong, Raymond Y.
    Nasis, Arthur
    RADIOLOGY, 2018, 289 (02) : 281 - 292
  • [27] MRI of Patients with Cardiac Implantable Electronic Devices
    Jessica A. Martinez
    Daniel B. Ennis
    Current Cardiovascular Imaging Reports, 2019, 12
  • [28] Radiotherapy in Patients With a Cardiac Implantable Electronic Device
    Sharifzadehgan, Ardalan
    Laurans, Marc
    Thuillot, Marine
    Huertas, Andres
    Baudinaud, Pierre
    Narayanan, Kumar
    Mirabel, Mariana
    Bibault, Jean-Emmanuel
    Frey, Pierre
    Waldmann, Victor
    Varlet, Emilie
    Amet, Denis
    Juin, Christophe
    Lavergne, Thomas
    Jouven, Xavier
    Giraud, Philippe
    Durdux, Catherine
    Marijon, Eloi
    AMERICAN JOURNAL OF CARDIOLOGY, 2020, 128 : 196 - 201
  • [29] Safe surgical management of patients with implantable cardiac devices
    Anjum, N.
    Child, N.
    Cooper, H.
    BRITISH JOURNAL OF DERMATOLOGY, 2014, 171 : 83 - 83
  • [30] Incidence of Cardiac Implantable Electronic Device Complications in Patients With Left Ventricular Assist Devices
    Gilge, Jasen L.
    Sbircea, Nicole
    Tong, Michael Z.
    Bauza, Karolis
    Cantillon, Daniel J.
    Srivastava, Ajay
    Khedraki, Rola
    Sheikh, Farooq H.
    Ahmed, Sara
    Herr, Jared
    Hsiao, Stephanie
    Patel, Parin J.
    D'Souza, Benjamin
    Ravichandran, Ashwin K.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2021, 7 (04) : 494 - 501