Adaptive planning for accelerated partial breast brachytherapy using the elliptical MammoSite balloon

被引:0
|
作者
Esthappan, J. [1 ]
机构
[1] Washington Univ, St Louis, MO USA
关键词
D O I
10.1118/1.2760710
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To demonstrate that accelerated partial breast brachytherapy using the elliptical MammoSite balloon requires a thorough evaluation of balloon geometry by use of volumetric imaging during the course of treatment, and may require adaptive planning. Methods and Materials: Patient was implanted with 4cm×6cm elliptical MammoSite. CT scans were acquired and sent to treatment planning system (TPS). Balloon and CTV (balloon plus 1cm margin, excluding 0.5cm from skin) were contoured. Dwell positions were activated along the catheter. Dwell times were optimized to deliver at least 90% of prescription dose, 340cGy, to greater than 90% of the CTV. Dwell times and positions were used for treatment of first fraction. Treatment was to be delivered in ten fractions, twice daily. The patient was re‐imaged using CT prior to subsequent fractions. We evaluated the effect of using the original treatment plan for subsequent fractions. The repeat scans were sent to TPS for contouring and catheter entry. Dwell times and positions from fraction one were used to recalculate dose distributions on repeat scans. The resulting plans were compared to that from fraction one in terms of target volume coverage, skin dose (<125% of prescription), volume of tissue receiving 150% and 200% of prescription dose (V150<50cc and V200<20cc). Results: Use of the first fraction plan for treatment of subsequent fractions led to acceptable target volume coverage, V150, and V200. However, skin dose increased due to gradual changes in balloon shape over the course of treatment. Subsequent fractions did require adjustments in dwell time to decrease skin dose. Conclusion: When using the elliptical MammoSite, the appropriateness of using the original plan for treatment of subsequent fractions depends on changes in balloon shape as well as volume, necessitating the acquisition of volumetric images prior to each treatment. Furthermore, volumetric imaging facilitates adaptive planning to account for these changes. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2414 / 2414
页数:1
相关论文
共 50 条
  • [21] Equivalent uniform dose for accelerated partial breast irradiation using the MammoSite applicator
    Stewart, Alexandra J.
    Hepel, Jaroslaw T.
    O'Farrell, Desmond A.
    Devlin, Phillip M.
    Price, Lori Lyn
    Dale, Roger G.
    Wazer, David E.
    RADIOTHERAPY AND ONCOLOGY, 2013, 108 (02) : 232 - 235
  • [22] EQUIVALENT UNIFORM DOSE FOR ACCELERATED PARTIAL BREAST IRRADIATION USING THE MAMMOSITE APPLICATOR
    Stewart, A.
    O'Farrell, D.
    Devlin, R.
    Dale, R.
    RADIOTHERAPY AND ONCOLOGY, 2009, 91 : S42 - S42
  • [23] Accelerated partial breast irradiation using multicatheter brachytherapy
    Rajiv Sarin
    Supriya Chopra
    Nature Clinical Practice Oncology, 2007, 4 : 382 - 383
  • [24] Radiographic Findings after Treatment with Balloon Brachytherapy Accelerated Partial Breast Irradiation
    Ibrahim, Nafisa B.
    Anandan, Srividya
    Hartman, Audrey L.
    McSweeney, Michelle
    Chun, Jeanette
    Mckee, Andrea
    Yang, Rebecca
    Kim, Cathleen
    RADIOGRAPHICS, 2015, 35 (01) : 6 - 13
  • [25] Dynamic Modulated Brachytherapy (DMBT) Balloon Applicator for Accelerated Partial Breast Irradiation
    Guy, Christopher L.
    Oh, Seungjong
    Han, Dae Yup
    Kim, Siyong
    Arthur, Douglas
    Song, William Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 104 (04): : 953 - 961
  • [26] Accelerated partial breast irradiation with intracavitary balloon brachytherapy may be not as simple as it was supposed to be
    Van Limbergen, Erik
    RADIOTHERAPY AND ONCOLOGY, 2009, 91 (02) : 147 - 149
  • [27] Accelerated partial breast irradiation using multicatheter brachytherapy
    Sarin, Rajiv
    Chopra, Supriya
    NATURE CLINICAL PRACTICE ONCOLOGY, 2007, 4 (07): : 382 - 383
  • [28] Virtual planning of multicatheter brachytherapy implants for accelerated partial breast irradiation
    Schmidt-Ullrich, PN
    Todor, DA
    Cuttino, LW
    Arthur, DW
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 3124 - 3127
  • [29] Day to day treatment variations of accelerated partial breast brachytherapy using a multi-lumen balloon
    Kuo, Hsiang-Chi
    Mehta, Keyur J.
    Hong, Linda
    Yaparpalvi, Ravindra
    Montgomery, Leslie L.
    Bodner, William
    Tome, Wolfgang A.
    Kalnicki, Shalom
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2014, 6 (01) : 68 - 75
  • [30] Investigation of interfraction variations of mammosite balloon applicator in high-dose-rate brachytherapy of partial breast irradiation
    Kim, Yongbok
    Johnson, Mark
    Trombetta, Mark G.
    Parda, David S.
    Miften, Moyed
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (01): : 305 - 313