Noise reduction strategies in freehand elasticity imaging

被引:0
|
作者
Hall, TJ [1 ]
Jiang, JF [1 ]
Zhu, YN [1 ]
Cook, LT [1 ]
机构
[1] Univ Kansas, Med Ctr, Dept Radiol, Kansas City, KS 66160 USA
关键词
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
We are developing a clinical ultrasonic imaging system for real-time estimation and display of tissue elastic properties. We have demonstrated that real-time feedback of elasticity images is essential for obtaining high-quality data (consecutive images with high spatial coherence). The key element to successful scanning is real-time visual feedback which guides the patient positioning and compression direction. Our data have clearly demonstrated nonlinearity in the strain properties of different tissue types. We have also demonstrated that a comparison of the area of a breast lesion observed in strain images versus B-mode images is a sensitive criterion for differentiating malignant from benign tumors. Frame-to-frame variability in strain images somewhat degrades the ability to observe these phenomena. Three strategies for reducing frame-to-frame strain image noise are described. The combination of these post-processing strategies provides a signicant improvement in the quality of long sequences of strain images.
引用
收藏
页码:1877 / 1880
页数:4
相关论文
共 50 条
  • [41] Laser speckle imaging with an active noise reduction scheme
    Völker, AC
    Zakharov, P
    Weber, B
    Buck, F
    Scheffold, F
    OPTICS EXPRESS, 2005, 13 (24): : 9782 - 9787
  • [42] A Noise Reduction Circuit Technique For CMOS Terahertz Imaging
    Boukhayma, Assim
    Dupret, Antoine
    Enz, Christian
    2015 INTERNATIONAL CONFERENCE ON NOISE AND FLUCTUATIONS (ICNF), 2015,
  • [43] NOISE REDUCTION FOR PATH TRACED IMAGING OF PARTICIPATING MEDIA
    Xu, Qing
    Liu, Yu
    Zhang, Ruijie
    Bao, Shiqiang
    Scopigno, Riccardo
    Sbert, Mateu
    19TH EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO-2011), 2011, : 1683 - 1687
  • [44] Digital Filtering for Noise Reduction in MCP Imaging Detectors
    Dou S.
    Fu L.
    Jia N.
    Wang T.
    Beijing Ligong Daxue Xuebao/Transaction of Beijing Institute of Technology, 2023, 43 (06): : 616 - 622
  • [45] BLOOD NOISE-REDUCTION IN INTRAVASCULAR ULTRASOUND IMAGING
    GRONNINGSAETER, A
    ANGELSEN, BAJ
    GRESLI, A
    TORP, HG
    LINKER, DT
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1995, 42 (02) : 200 - 209
  • [46] Elasticity Imaging
    Sarvazyan, Armen
    Hall, Timothy J.
    CURRENT MEDICAL IMAGING REVIEWS, 2011, 7 (04) : 254 - 254
  • [47] Elasticity Imaging
    Sarvazyan, Armen
    Hall, Timothy J.
    CURRENT MEDICAL IMAGING REVIEWS, 2012, 8 (01) : 2 - 2
  • [48] Trifurcated lined ducts: A comprehensive study on noise reduction strategies
    Nawaz, Touqeer
    Afzal, Muhammad
    PLOS ONE, 2024, 19 (07):
  • [49] Single and Multiple Microphone Noise Reduction Strategies in Cochlear Implants
    Kokkinakis, Kostas
    Azimi, Behnam
    Hu, Yi
    Friedland, David R.
    TRENDS IN AMPLIFICATION, 2012, 16 (02): : 102 - 116
  • [50] Biological tissue strain imaging with freehand elastography
    Brusseau, E.
    Deprez, J-F
    Duboeuf, F.
    Basset, O.
    JOURNAL DE RADIOLOGIE, 2007, 88 (11): : 1823 - 1831