Noise reduction strategies in freehand elasticity imaging

被引:0
|
作者
Hall, TJ [1 ]
Jiang, JF [1 ]
Zhu, YN [1 ]
Cook, LT [1 ]
机构
[1] Univ Kansas, Med Ctr, Dept Radiol, Kansas City, KS 66160 USA
关键词
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
We are developing a clinical ultrasonic imaging system for real-time estimation and display of tissue elastic properties. We have demonstrated that real-time feedback of elasticity images is essential for obtaining high-quality data (consecutive images with high spatial coherence). The key element to successful scanning is real-time visual feedback which guides the patient positioning and compression direction. Our data have clearly demonstrated nonlinearity in the strain properties of different tissue types. We have also demonstrated that a comparison of the area of a breast lesion observed in strain images versus B-mode images is a sensitive criterion for differentiating malignant from benign tumors. Frame-to-frame variability in strain images somewhat degrades the ability to observe these phenomena. Three strategies for reducing frame-to-frame strain image noise are described. The combination of these post-processing strategies provides a signicant improvement in the quality of long sequences of strain images.
引用
收藏
页码:1877 / 1880
页数:4
相关论文
共 50 条
  • [1] Freehand elasticity imaging of breast disease
    Tranquart, F.
    Fuechsel, F.G.
    Doyley, M.M.
    Bush, N.L.
    Miller, N.
    Svensson, W.E.
    Bell, D.S.
    Gui, G.
    Bamber, J.C.
    Cosgrove, D.O.
    Ultrasound in Medicine and Biology, 2000, 26 (SUPPL. 2):
  • [2] Assisted-Freehand Ultrasound Elasticity Imaging
    Kadour, Michael J.
    Noble, J. Alison
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (01) : 36 - 43
  • [3] In vivo real-time freehand elasticity imaging
    Hall, TJ
    Zhu, YN
    Spalding, CS
    Cook, LT
    2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, 2002, : 805 - 808
  • [4] Freehand elasticity imaging using speckle decorrelation rate
    Bamber, JC
    Bush, NL
    ACOUSTICAL IMAGING, VOL 22, 1996, 22 : 285 - 292
  • [5] In vivo results of real-time freehand elasticity imaging
    Hall, TJ
    Zhu, YN
    Spalding, CS
    Cook, LT
    2001 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2001, : 1653 - 1657
  • [6] A feasibility study of prostate needle biopsy supported by freehand elasticity imaging
    Yamakawa, M
    Nitta, N
    Shiina, T
    Matsumura, T
    Tamano, S
    Mitake, T
    Miyanaga, N
    Akaza, H
    2003 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2003, : 1254 - 1257
  • [7] High-speed freehand tissue elasticity imaging for breast diagnosis
    Yamakawa, M
    Nitta, N
    Shiina, T
    Matsumura, T
    Tamano, S
    Mitake, T
    Ueno, E
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2003, 42 (5B): : 3265 - 3270
  • [8] High-speed freehand tissue elasticity imaging for breast diagnosis
    Yamakawa, M., 1600, Japan Society of Applied Physics (42):
  • [9] In vivo breast examination by real-time freehand elasticity imaging system
    Shiina, T
    Ueno, E
    RESEARCH AND DEVELOPMENT IN BREAST ULTRASOUND, 2005, : 7 - 15
  • [10] Quantitative evaluation of noise reduction strategies in dual-energy imaging
    Warp, RJ
    Dobbins, JT
    MEDICAL PHYSICS, 2003, 30 (02) : 190 - 198