Mass transport behavior of electrochemical species through plasma-polymerized thin film on platinum electrode

被引:37
|
作者
Hiratsuka, A
Muguruma, H [1 ]
Nagata, R
Nakamura, R
Sato, K
Uchiyama, S
Karube, I
机构
[1] Kochi Univ Technol, Dept Environm Syst Engn, Tosayamada, Kochi 7828502, Japan
[2] Univ Tokyo, Adv Sci & Technol Res Ctr, Tokyo 1538904, Japan
[3] Dai Nippon Printing Co Ltd, Cent Res Inst, Kashiwa, Chiba 2770871, Japan
关键词
plasma-polymerized film; electrochemical sensing; chemically modified electrode; apparent diffusion coefficient;
D O I
10.1016/S0376-7388(00)00403-8
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
We propose a novel method for generating thin film coating for use on a platinum (Pt) electrode. This is accomplished by a plasma-polymerized film (PPF), which is deposited directly onto the substrate under dry condition. The resulting films are extremely thin (<100 nm), have good adherence to the substrate (electrode), and have a highly-cross-linked network structure. The PPF-deposited Pt electrode shows a high selectivity towards targeted species without decreasing the sensitivity (i.e. maintaining a high electrical signal). This property is partly attributed to size discrimination from a highly-cross-linked network structure in the film. Moreover, an acetonitrile PPF-deposited PI electrode showed accumulation ability for hydrogen peroxide detection; the sensitivity of the PPF-deposited electrode (30-59 nm of film thickness) is one and half times larger than that of bale electrode. Chronocoulometric data support this effect. A hexadiene PPF-deposited Pt electrode also showed high selectivity between dopamine and ascorbic acid compared with a hare Pt electrode; the selectivity ratio for PPF-deposited electrode (37 nm of film thickness) is 12, whereas that of the bare electrode is 4.6. We demonstrate and discuss mass transport behavior of electrochemical species through plasma-polymerized thin film on platinum electrode. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:25 / 34
页数:10
相关论文
共 50 条
  • [31] Selective Detection of NADH with Neutral Red Functionalized Carbon Nanotube/Plasma-polymerized Film Composite Electrode
    Hoshino, Tatsuya
    Muguruma, Hitoshi
    ELECTROCHEMISTRY, 2012, 80 (02) : 85 - 87
  • [32] Improving the oxygen barrier properties of PET polymer by radio frequency plasma-polymerized SiOxNy thin film
    Shahpanah, Marjan
    Mehrabian, Somayeh
    Abbasi-Firouzjah, Marzieh
    Shokri, Babak
    SURFACE & COATINGS TECHNOLOGY, 2019, 358 : 91 - 97
  • [33] ELECTRON-SPIN-RESONANCE STUDY ON RADICAL EXISTING IN PLASMA-POLYMERIZED STYRENE THIN-FILM
    OHNO, K
    ISHII, N
    SOHMA, J
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1983, 22 (06): : 996 - 1000
  • [34] EFFECTS OF SURFACE FINISHING OF STAINLESS-STEEL SHEETS ON FORMATION OF PLASMA-POLYMERIZED THIN-FILM
    MASUHARA, K
    SAWAYA, K
    HIRAOKA, K
    KATO, R
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1995, 81 (05): : 553 - 558
  • [35] CHEMICAL-STRUCTURE AND DURABILITY OF A PLASMA-POLYMERIZED PROTECTIVE LAYER FOR THIN-FILM MAGNETIC DISKS
    KOISHI, R
    YAMAMOTO, T
    SHINOHARA, M
    TRIBOLOGY TRANSACTIONS, 1993, 36 (01): : 49 - 54
  • [36] An amperometric biosensor for glucose based on a composite electrode of glucose dehydrogenase, carbon nanotubes, and plasma-polymerized thin films
    Muguruma, Hitoshi
    Yoshida, Shunsuke
    Urata, Muneyuki
    Fujisawa, Kohta
    Matsui, Yasunori
    ELECTROCHEMISTRY, 2008, 76 (08) : 545 - 548
  • [37] The conductive behavior and structural characteristics in the I+-beam-implanted layer of plasma-polymerized pyrrole film
    Tong, ZS
    Wu, MZ
    Pu, TS
    Zhang, ZY
    Zhang, J
    Jin, RP
    Zhu, DZ
    Zhu, FY
    Cao, DX
    Cao, JQ
    JOURNAL OF APPLIED POLYMER SCIENCE, 1998, 69 (09) : 1743 - 1751
  • [38] Amperometric Glucose Biosensor Based on Mediated Electron Transfer between Immobilized Glucose Oxidase and Plasma-polymerized Thin Film of Dimethylaminomethylferrocene on Sputtered Gold Electrode
    Yoshihiro Kase
    Hitoshi Muguruma
    Analytical Sciences, 2004, 20 : 1143 - 1146
  • [39] Amperometric glucose biosensor based on mediated electron transfer between immobilized glucose oxidase and plasma-polymerized thin film of dimethylaminomethylferrocene on sputtered gold electrode
    Kase, Y
    Muguruma, H
    ANALYTICAL SCIENCES, 2004, 20 (08) : 1143 - 1146
  • [40] Conventional measurement method of film resistance of plasma-polymerized thin films using a high-resistance meter
    Kurosawa, S
    Miura, H
    Tozuka, M
    Yamahira, S
    Aizawa, H
    Kongswan, K
    Matsunaga, M
    Yamada, K
    Hirata, M
    JOURNAL OF PHOTOPOLYMER SCIENCE AND TECHNOLOGY, 2003, 16 (01) : 43 - 48